The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study

Detalhes bibliográficos
Autor(a) principal: TAWSE-SMITH,Andrew
Data de Publicação: 2016
Outros Autores: KOTA,Akash, JAYAWEERA,Yathen, VUUREN,Wendy Jansen van, MA,Sunyoung
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242016000100326
Resumo: Abstract: To analyse the changes of surface characteristics of machined and moderately roughened titanium disks following a standardised implantoplasty protocol. Forty titanium discs (machined: n = 20; moderately roughened: n = 20) were instrumented with one half of each disc maintained as the control (non-instrumented). The standardised implantoplasty protocol was carried out using a custom jig with the sequential change of burs: 1) Regular grit diamond [10s], 2) Super-fine grit diamond [10s], 3) Brownie(tm) silicone polisher [15s], 4) Greenie(tm) silicone polisher [15s]. Surface topography was analysed using confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Energy dispersive x-ray spectroscopy (EDS) was used to measure the elemental profiles of each disc. Quantitative analysis showed similar changes in level of roughness between the machined and moderately roughened titanium discs. CLSM demonstrated an increased roughness (Ra and Sa values) after polishing with a regular grit diamond bur when compared to the uninstrumented surfaces. Although the roughness decreased after the further polishing with the super-fine grit diamond bur, subsequent instrumentation using silicon burs tended to increase the roughness, albeit being statistically insignificant. There was a residue of silicon particles despite the irrigation after each polishing stage. The proposed implantoplasty protocol did not achieve a sufficient level of smoothness on the machined or moderately roughened titanium surfaces when compared to the Ra threshold. Further research is recommended to test the efficacy of each bur on titanium surfaces with longer duration using actual oral implants to allow better comparison.
id SBPQO-1_04260e27135fd12f78559db27df732c1
oai_identifier_str oai:scielo:S1806-83242016000100326
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro studyPeri-implantitisDental ImplantsTitaniumMicroscopy, ConfocalAbstract: To analyse the changes of surface characteristics of machined and moderately roughened titanium disks following a standardised implantoplasty protocol. Forty titanium discs (machined: n = 20; moderately roughened: n = 20) were instrumented with one half of each disc maintained as the control (non-instrumented). The standardised implantoplasty protocol was carried out using a custom jig with the sequential change of burs: 1) Regular grit diamond [10s], 2) Super-fine grit diamond [10s], 3) Brownie(tm) silicone polisher [15s], 4) Greenie(tm) silicone polisher [15s]. Surface topography was analysed using confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Energy dispersive x-ray spectroscopy (EDS) was used to measure the elemental profiles of each disc. Quantitative analysis showed similar changes in level of roughness between the machined and moderately roughened titanium discs. CLSM demonstrated an increased roughness (Ra and Sa values) after polishing with a regular grit diamond bur when compared to the uninstrumented surfaces. Although the roughness decreased after the further polishing with the super-fine grit diamond bur, subsequent instrumentation using silicon burs tended to increase the roughness, albeit being statistically insignificant. There was a residue of silicon particles despite the irrigation after each polishing stage. The proposed implantoplasty protocol did not achieve a sufficient level of smoothness on the machined or moderately roughened titanium surfaces when compared to the Ra threshold. Further research is recommended to test the efficacy of each bur on titanium surfaces with longer duration using actual oral implants to allow better comparison.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2016-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242016000100326Brazilian Oral Research v.30 n.1 2016reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/1807-3107bor-2016.vol30.0137info:eu-repo/semantics/openAccessTAWSE-SMITH,AndrewKOTA,AkashJAYAWEERA,YathenVUUREN,Wendy Jansen vanMA,Sunyoungeng2016-12-19T00:00:00Zoai:scielo:S1806-83242016000100326Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2016-12-19T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
title The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
spellingShingle The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
TAWSE-SMITH,Andrew
Peri-implantitis
Dental Implants
Titanium
Microscopy, Confocal
title_short The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
title_full The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
title_fullStr The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
title_full_unstemmed The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
title_sort The effect of standardised implantoplasty protocol on titanium surface roughness: an in-vitro study
author TAWSE-SMITH,Andrew
author_facet TAWSE-SMITH,Andrew
KOTA,Akash
JAYAWEERA,Yathen
VUUREN,Wendy Jansen van
MA,Sunyoung
author_role author
author2 KOTA,Akash
JAYAWEERA,Yathen
VUUREN,Wendy Jansen van
MA,Sunyoung
author2_role author
author
author
author
dc.contributor.author.fl_str_mv TAWSE-SMITH,Andrew
KOTA,Akash
JAYAWEERA,Yathen
VUUREN,Wendy Jansen van
MA,Sunyoung
dc.subject.por.fl_str_mv Peri-implantitis
Dental Implants
Titanium
Microscopy, Confocal
topic Peri-implantitis
Dental Implants
Titanium
Microscopy, Confocal
description Abstract: To analyse the changes of surface characteristics of machined and moderately roughened titanium disks following a standardised implantoplasty protocol. Forty titanium discs (machined: n = 20; moderately roughened: n = 20) were instrumented with one half of each disc maintained as the control (non-instrumented). The standardised implantoplasty protocol was carried out using a custom jig with the sequential change of burs: 1) Regular grit diamond [10s], 2) Super-fine grit diamond [10s], 3) Brownie(tm) silicone polisher [15s], 4) Greenie(tm) silicone polisher [15s]. Surface topography was analysed using confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Energy dispersive x-ray spectroscopy (EDS) was used to measure the elemental profiles of each disc. Quantitative analysis showed similar changes in level of roughness between the machined and moderately roughened titanium discs. CLSM demonstrated an increased roughness (Ra and Sa values) after polishing with a regular grit diamond bur when compared to the uninstrumented surfaces. Although the roughness decreased after the further polishing with the super-fine grit diamond bur, subsequent instrumentation using silicon burs tended to increase the roughness, albeit being statistically insignificant. There was a residue of silicon particles despite the irrigation after each polishing stage. The proposed implantoplasty protocol did not achieve a sufficient level of smoothness on the machined or moderately roughened titanium surfaces when compared to the Ra threshold. Further research is recommended to test the efficacy of each bur on titanium surfaces with longer duration using actual oral implants to allow better comparison.
publishDate 2016
dc.date.none.fl_str_mv 2016-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242016000100326
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242016000100326
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-3107bor-2016.vol30.0137
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.30 n.1 2016
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318325191147520