Resumo: The purpose of this study was to evaluate the Shore A hardness and surface roughness of two silicones for maxillofacial prosthetic treatment, under the influence of chemical disinfection and storage. Twenty-eight specimens were obtained, half of which were made of Silastic MDX 4-4210 silicone and, the other half were made of Silastic 732 RTV silicone. The specimens were divided into four groups: Silastic 732 RTV and MDX 4-4210 with disinfection 3 times a week with Efferdent tablets and the same materials without disinfection. The hardness of the materials was analyzed with a Shore A Durometer. The surface roughness was established by a digital portable roughness tester, initially and 2 months after the confection of the specimens. A variance test was applied (2-way ANOVA), followed by Tukey test (the level of significance was set at 1%). The storage time factor statistically influenced (p < 0.01) the materials' properties of hardness and roughness. MDX 4-4210 (28.59 Shore A, 0.789 Ra) presented higher values than Silastic 732 RTV (18.08 Shore A, 0.656 Ra) for both properties. Regarding the disinfection period, there was no significant difference in any of the materials tested.
id SBPQO-1_1f152c9c96a1f479bea3d4e021940d47
oai_identifier_str oai:scielo:S1806-83242009000100009
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfectionMaxillofacial prosthesisDisinfectionHardnessThe purpose of this study was to evaluate the Shore A hardness and surface roughness of two silicones for maxillofacial prosthetic treatment, under the influence of chemical disinfection and storage. Twenty-eight specimens were obtained, half of which were made of Silastic MDX 4-4210 silicone and, the other half were made of Silastic 732 RTV silicone. The specimens were divided into four groups: Silastic 732 RTV and MDX 4-4210 with disinfection 3 times a week with Efferdent tablets and the same materials without disinfection. The hardness of the materials was analyzed with a Shore A Durometer. The surface roughness was established by a digital portable roughness tester, initially and 2 months after the confection of the specimens. A variance test was applied (2-way ANOVA), followed by Tukey test (the level of significance was set at 1%). The storage time factor statistically influenced (p < 0.01) the materials' properties of hardness and roughness. MDX 4-4210 (28.59 Shore A, 0.789 Ra) presented higher values than Silastic 732 RTV (18.08 Shore A, 0.656 Ra) for both properties. Regarding the disinfection period, there was no significant difference in any of the materials tested.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2009-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000100009Brazilian Oral Research v.23 n.1 2009reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242009000100009info:eu-repo/semantics/openAccessGoiato,Marcelo CoelhoPesqueira,Aldiéris AlvesSantos,Daniela Micheline dosDekon,Stefan Fiúza de Carvalhoeng2009-10-20T00:00:00Zoai:scielo:S1806-83242009000100009Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2009-10-20T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
title Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
spellingShingle Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
Goiato,Marcelo Coelho
Maxillofacial prosthesis
Disinfection
Hardness
title_short Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
title_full Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
title_fullStr Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
title_full_unstemmed Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
title_sort Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection
author Goiato,Marcelo Coelho
author_facet Goiato,Marcelo Coelho
Pesqueira,Aldiéris Alves
Santos,Daniela Micheline dos
Dekon,Stefan Fiúza de Carvalho
author_role author
author2 Pesqueira,Aldiéris Alves
Santos,Daniela Micheline dos
Dekon,Stefan Fiúza de Carvalho
author2_role author
author
author
dc.contributor.author.fl_str_mv Goiato,Marcelo Coelho
Pesqueira,Aldiéris Alves
Santos,Daniela Micheline dos
Dekon,Stefan Fiúza de Carvalho
dc.subject.por.fl_str_mv Maxillofacial prosthesis
Disinfection
Hardness
topic Maxillofacial prosthesis
Disinfection
Hardness
description The purpose of this study was to evaluate the Shore A hardness and surface roughness of two silicones for maxillofacial prosthetic treatment, under the influence of chemical disinfection and storage. Twenty-eight specimens were obtained, half of which were made of Silastic MDX 4-4210 silicone and, the other half were made of Silastic 732 RTV silicone. The specimens were divided into four groups: Silastic 732 RTV and MDX 4-4210 with disinfection 3 times a week with Efferdent tablets and the same materials without disinfection. The hardness of the materials was analyzed with a Shore A Durometer. The surface roughness was established by a digital portable roughness tester, initially and 2 months after the confection of the specimens. A variance test was applied (2-way ANOVA), followed by Tukey test (the level of significance was set at 1%). The storage time factor statistically influenced (p < 0.01) the materials' properties of hardness and roughness. MDX 4-4210 (28.59 Shore A, 0.789 Ra) presented higher values than Silastic 732 RTV (18.08 Shore A, 0.656 Ra) for both properties. Regarding the disinfection period, there was no significant difference in any of the materials tested.
publishDate 2009
dc.date.none.fl_str_mv 2009-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000100009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242009000100009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242009000100009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.23 n.1 2009
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318321599774720