Mechanical evaluation of space closure loops in Orthodontics

Detalhes bibliográficos
Autor(a) principal: Rodrigues,Eduardo Uggeri
Data de Publicação: 2011
Outros Autores: Maruo,Hiroshi, Guariza Filho,Odilon, Tanaka,Orlando, Camargo,Elisa Souza
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000100011
Resumo: This study evaluated the mechanical performance of teardrop-shaped loops and teardrop-shaped loops with helix used in orthodontic space closure. Sixty retraction loops made with 0.019" x 0.025" stainless steel (SS) and beta-titanium (BT) wires were used. They were attached to a testing machine to measure the magnitudes of the sagittal force and the load-deflection ratio necessary for 1 mm, 2 mm and 3 mm activation. The results demonstrated that the BT alloy presented significantly smaller mean values (p < 0.01) of sagittal force and load-deflection than the SS alloy. The loop with the highest mean value of sagittal force and load-deflection was the teardrop-shaped loop (p < 0.01). Differences were observed in the mean values of sagittal force and load-deflection among activations, and the highest mean value was found in the activation of 3 mm, while the smallest mean value was evident in the activation of 1 mm (p < 0.01). It could be concluded that the metallic alloy used and the presence of a helix in configuration of the loops may have a strong influence on the sagittal force produced and on the load-deflection ratio; the teardrop-shaped loops and teardrop-shaped loops with helix in BT presented the release of lighter forces; the teardrop-shaped loop in SS generated a high load-deflection ratio, providing high magnitudes of horizontal force during its deactivation.
id SBPQO-1_3abb10fe372e0dc9676ff0adfd5e5a0a
oai_identifier_str oai:scielo:S1806-83242011000100011
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Mechanical evaluation of space closure loops in OrthodonticsBiomechanicsOrthodontic Space ClosureStainless SteelThis study evaluated the mechanical performance of teardrop-shaped loops and teardrop-shaped loops with helix used in orthodontic space closure. Sixty retraction loops made with 0.019" x 0.025" stainless steel (SS) and beta-titanium (BT) wires were used. They were attached to a testing machine to measure the magnitudes of the sagittal force and the load-deflection ratio necessary for 1 mm, 2 mm and 3 mm activation. The results demonstrated that the BT alloy presented significantly smaller mean values (p < 0.01) of sagittal force and load-deflection than the SS alloy. The loop with the highest mean value of sagittal force and load-deflection was the teardrop-shaped loop (p < 0.01). Differences were observed in the mean values of sagittal force and load-deflection among activations, and the highest mean value was found in the activation of 3 mm, while the smallest mean value was evident in the activation of 1 mm (p < 0.01). It could be concluded that the metallic alloy used and the presence of a helix in configuration of the loops may have a strong influence on the sagittal force produced and on the load-deflection ratio; the teardrop-shaped loops and teardrop-shaped loops with helix in BT presented the release of lighter forces; the teardrop-shaped loop in SS generated a high load-deflection ratio, providing high magnitudes of horizontal force during its deactivation.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2011-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000100011Brazilian Oral Research v.25 n.1 2011reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242011005000003info:eu-repo/semantics/openAccessRodrigues,Eduardo UggeriMaruo,HiroshiGuariza Filho,OdilonTanaka,OrlandoCamargo,Elisa Souzaeng2011-02-17T00:00:00Zoai:scielo:S1806-83242011000100011Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2011-02-17T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Mechanical evaluation of space closure loops in Orthodontics
title Mechanical evaluation of space closure loops in Orthodontics
spellingShingle Mechanical evaluation of space closure loops in Orthodontics
Rodrigues,Eduardo Uggeri
Biomechanics
Orthodontic Space Closure
Stainless Steel
title_short Mechanical evaluation of space closure loops in Orthodontics
title_full Mechanical evaluation of space closure loops in Orthodontics
title_fullStr Mechanical evaluation of space closure loops in Orthodontics
title_full_unstemmed Mechanical evaluation of space closure loops in Orthodontics
title_sort Mechanical evaluation of space closure loops in Orthodontics
author Rodrigues,Eduardo Uggeri
author_facet Rodrigues,Eduardo Uggeri
Maruo,Hiroshi
Guariza Filho,Odilon
Tanaka,Orlando
Camargo,Elisa Souza
author_role author
author2 Maruo,Hiroshi
Guariza Filho,Odilon
Tanaka,Orlando
Camargo,Elisa Souza
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Rodrigues,Eduardo Uggeri
Maruo,Hiroshi
Guariza Filho,Odilon
Tanaka,Orlando
Camargo,Elisa Souza
dc.subject.por.fl_str_mv Biomechanics
Orthodontic Space Closure
Stainless Steel
topic Biomechanics
Orthodontic Space Closure
Stainless Steel
description This study evaluated the mechanical performance of teardrop-shaped loops and teardrop-shaped loops with helix used in orthodontic space closure. Sixty retraction loops made with 0.019" x 0.025" stainless steel (SS) and beta-titanium (BT) wires were used. They were attached to a testing machine to measure the magnitudes of the sagittal force and the load-deflection ratio necessary for 1 mm, 2 mm and 3 mm activation. The results demonstrated that the BT alloy presented significantly smaller mean values (p < 0.01) of sagittal force and load-deflection than the SS alloy. The loop with the highest mean value of sagittal force and load-deflection was the teardrop-shaped loop (p < 0.01). Differences were observed in the mean values of sagittal force and load-deflection among activations, and the highest mean value was found in the activation of 3 mm, while the smallest mean value was evident in the activation of 1 mm (p < 0.01). It could be concluded that the metallic alloy used and the presence of a helix in configuration of the loops may have a strong influence on the sagittal force produced and on the load-deflection ratio; the teardrop-shaped loops and teardrop-shaped loops with helix in BT presented the release of lighter forces; the teardrop-shaped loop in SS generated a high load-deflection ratio, providing high magnitudes of horizontal force during its deactivation.
publishDate 2011
dc.date.none.fl_str_mv 2011-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000100011
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242011000100011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242011005000003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.25 n.1 2011
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318322521473024