Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Oral Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500403 |
Resumo: | This study evaluated: I) the effect of photo-activation through ceramics on the degree of conversion (DC) and on the Knoop hardness (KHN) of light- and dual-cured resin cements; and II) two different protocols for obtaining the spectra of uncured materials, to determine the DC of a dual-cured resin cement. Thin films of cements were photo-activated through ceramics [feldspathic porcelain (FP); lithium disilicate glass-ceramics of low translucency (e.max-LT), medium opacity (e.max-MO) and high translucency (e.max-HT); glass-infiltrated alumina composite (IC) and polycrystalline zirconia (ZR)] with thicknesses of 1.5 and 2.0 mm. DC was analyzed by Fourier transform infrared (FTIR) spectroscopy. Two protocols were used to obtain the spectra of the uncured materials: I) base and catalyst pastes were mixed, and II) thin films of base and catalyst pastes were obtained separately, and an average was obtained. KHN assessment was performed with cylindrical specimens. The results were analyzed by ANOVA and Tukey's test (α= 0.05). The light-cured cement showed higher DC (61.9%) than the dual-cured cement (55.7%). The DC varied as follows: FP (65.4%), e.max-HT (65.1%), e.max-LT (61.8%), e.max-MO (60.9%), ZR (54.8%), and IC (44.9%). The light-cured cement showed lower KHN (22.0) than the dual-cured (25.6) cement. The cements cured under 1.5 mm spacers showed higher KHN (26.2) than when polymerized under 2.0 mm ceramics (21.3). Regarding the two protocols, there were significant differences only in three groups. Thus, both methods can be considered appropriate. The physical and mechanical properties of resin cements may be affected by the thickness and microstructure of the ceramic material interposed during photo-activation. |
id |
SBPQO-1_3de468502cf97df768f082366ed1abd3 |
---|---|
oai_identifier_str |
oai:scielo:S1806-83242013000500403 |
network_acronym_str |
SBPQO-1 |
network_name_str |
Brazilian Oral Research |
repository_id_str |
|
spelling |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cementsResin CementsCeramicsPolymerizationThis study evaluated: I) the effect of photo-activation through ceramics on the degree of conversion (DC) and on the Knoop hardness (KHN) of light- and dual-cured resin cements; and II) two different protocols for obtaining the spectra of uncured materials, to determine the DC of a dual-cured resin cement. Thin films of cements were photo-activated through ceramics [feldspathic porcelain (FP); lithium disilicate glass-ceramics of low translucency (e.max-LT), medium opacity (e.max-MO) and high translucency (e.max-HT); glass-infiltrated alumina composite (IC) and polycrystalline zirconia (ZR)] with thicknesses of 1.5 and 2.0 mm. DC was analyzed by Fourier transform infrared (FTIR) spectroscopy. Two protocols were used to obtain the spectra of the uncured materials: I) base and catalyst pastes were mixed, and II) thin films of base and catalyst pastes were obtained separately, and an average was obtained. KHN assessment was performed with cylindrical specimens. The results were analyzed by ANOVA and Tukey's test (α= 0.05). The light-cured cement showed higher DC (61.9%) than the dual-cured cement (55.7%). The DC varied as follows: FP (65.4%), e.max-HT (65.1%), e.max-LT (61.8%), e.max-MO (60.9%), ZR (54.8%), and IC (44.9%). The light-cured cement showed lower KHN (22.0) than the dual-cured (25.6) cement. The cements cured under 1.5 mm spacers showed higher KHN (26.2) than when polymerized under 2.0 mm ceramics (21.3). Regarding the two protocols, there were significant differences only in three groups. Thus, both methods can be considered appropriate. The physical and mechanical properties of resin cements may be affected by the thickness and microstructure of the ceramic material interposed during photo-activation.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2013-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500403Brazilian Oral Research v.27 n.5 2013reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242013000500004info:eu-repo/semantics/openAccessCalgaro,Patricia Angelica MilaniFuruse,Adilson YoshioCorrer,Gisele MariaOrnaghi,Barbara PickGonzaga,Carla Castigliaeng2013-10-08T00:00:00Zoai:scielo:S1806-83242013000500403Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2013-10-08T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false |
dc.title.none.fl_str_mv |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements |
title |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements |
spellingShingle |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements Calgaro,Patricia Angelica Milani Resin Cements Ceramics Polymerization |
title_short |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements |
title_full |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements |
title_fullStr |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements |
title_full_unstemmed |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements |
title_sort |
Influence of the interposition of ceramic spacers on the degree of conversion and the hardness of resin cements |
author |
Calgaro,Patricia Angelica Milani |
author_facet |
Calgaro,Patricia Angelica Milani Furuse,Adilson Yoshio Correr,Gisele Maria Ornaghi,Barbara Pick Gonzaga,Carla Castiglia |
author_role |
author |
author2 |
Furuse,Adilson Yoshio Correr,Gisele Maria Ornaghi,Barbara Pick Gonzaga,Carla Castiglia |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Calgaro,Patricia Angelica Milani Furuse,Adilson Yoshio Correr,Gisele Maria Ornaghi,Barbara Pick Gonzaga,Carla Castiglia |
dc.subject.por.fl_str_mv |
Resin Cements Ceramics Polymerization |
topic |
Resin Cements Ceramics Polymerization |
description |
This study evaluated: I) the effect of photo-activation through ceramics on the degree of conversion (DC) and on the Knoop hardness (KHN) of light- and dual-cured resin cements; and II) two different protocols for obtaining the spectra of uncured materials, to determine the DC of a dual-cured resin cement. Thin films of cements were photo-activated through ceramics [feldspathic porcelain (FP); lithium disilicate glass-ceramics of low translucency (e.max-LT), medium opacity (e.max-MO) and high translucency (e.max-HT); glass-infiltrated alumina composite (IC) and polycrystalline zirconia (ZR)] with thicknesses of 1.5 and 2.0 mm. DC was analyzed by Fourier transform infrared (FTIR) spectroscopy. Two protocols were used to obtain the spectra of the uncured materials: I) base and catalyst pastes were mixed, and II) thin films of base and catalyst pastes were obtained separately, and an average was obtained. KHN assessment was performed with cylindrical specimens. The results were analyzed by ANOVA and Tukey's test (α= 0.05). The light-cured cement showed higher DC (61.9%) than the dual-cured cement (55.7%). The DC varied as follows: FP (65.4%), e.max-HT (65.1%), e.max-LT (61.8%), e.max-MO (60.9%), ZR (54.8%), and IC (44.9%). The light-cured cement showed lower KHN (22.0) than the dual-cured (25.6) cement. The cements cured under 1.5 mm spacers showed higher KHN (26.2) than when polymerized under 2.0 mm ceramics (21.3). Regarding the two protocols, there were significant differences only in three groups. Thus, both methods can be considered appropriate. The physical and mechanical properties of resin cements may be affected by the thickness and microstructure of the ceramic material interposed during photo-activation. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500403 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500403 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1806-83242013000500004 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
dc.source.none.fl_str_mv |
Brazilian Oral Research v.27 n.5 2013 reponame:Brazilian Oral Research instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO) instacron:SBPQO |
instname_str |
Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
instacron_str |
SBPQO |
institution |
SBPQO |
reponame_str |
Brazilian Oral Research |
collection |
Brazilian Oral Research |
repository.name.fl_str_mv |
Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
repository.mail.fl_str_mv |
pob@edu.usp.br||bor@sbpqo.org.br |
_version_ |
1750318323414859776 |