Characterization of titanium surfaces for dental implants with inorganic contaminant
Autor(a) principal: | |
---|---|
Data de Publicação: | 2005 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Oral Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242005000200006 |
Resumo: | The aim of this research was to characterize titanium surfaces blasted with aluminum oxide (Al2O3) particles using the KS 400 digital image processing program. Samples of grade II titanium plates were submitted to blasting processes using particles of Al2O3, and treated with a hydrofluoric acid-based solution. Three digital images from each sample surface were obtained using Scanning Electron Microscopy, and half-quantitative chemical analyses were subsequently performed using Electron Dispersive Spectroscopy (EDS). In addition, parameters related to the alumina phase, such as the concentration level, the area and perimeter of the particles and their circular form factor were measured using KS 400. The mechanical/chemical treatment caused depressions up to 10 µm on homogeneous surfaces. Although the chemical attack significantly removed the alumina phase, residual particles could still be identified by the EDS. The average area occupied by the alumina phase on the samples surfaces was 469.32 (± 284.98) µm², the particle average perimeter was 81.61 (± 27.68) µm, and the mean circular form factor was 0.60 (± 0.05). Characterizing the titanium surface is essential in the evaluation of the material manufacturing process because the presence of residual aluminum particles may have deleterious effects on the formation of the osseous/implant tissue. |
id |
SBPQO-1_440925eab8767fef1cb2026ddd203779 |
---|---|
oai_identifier_str |
oai:scielo:S1806-83242005000200006 |
network_acronym_str |
SBPQO-1 |
network_name_str |
Brazilian Oral Research |
repository_id_str |
|
spelling |
Characterization of titanium surfaces for dental implants with inorganic contaminantTitaniumDental implantsAluminum oxideImage processing, computer-assistedThe aim of this research was to characterize titanium surfaces blasted with aluminum oxide (Al2O3) particles using the KS 400 digital image processing program. Samples of grade II titanium plates were submitted to blasting processes using particles of Al2O3, and treated with a hydrofluoric acid-based solution. Three digital images from each sample surface were obtained using Scanning Electron Microscopy, and half-quantitative chemical analyses were subsequently performed using Electron Dispersive Spectroscopy (EDS). In addition, parameters related to the alumina phase, such as the concentration level, the area and perimeter of the particles and their circular form factor were measured using KS 400. The mechanical/chemical treatment caused depressions up to 10 µm on homogeneous surfaces. Although the chemical attack significantly removed the alumina phase, residual particles could still be identified by the EDS. The average area occupied by the alumina phase on the samples surfaces was 469.32 (± 284.98) µm², the particle average perimeter was 81.61 (± 27.68) µm, and the mean circular form factor was 0.60 (± 0.05). Characterizing the titanium surface is essential in the evaluation of the material manufacturing process because the presence of residual aluminum particles may have deleterious effects on the formation of the osseous/implant tissue.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2005-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242005000200006Brazilian Oral Research v.19 n.2 2005reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242005000200006info:eu-repo/semantics/openAccessDiniz,Marilia GarciaPinheiro,Marco Antonio SantosAndrade Junior,Antonio Carlos CanabarroFischer,Ricardo Guimarãeseng2005-09-08T00:00:00Zoai:scielo:S1806-83242005000200006Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2005-09-08T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false |
dc.title.none.fl_str_mv |
Characterization of titanium surfaces for dental implants with inorganic contaminant |
title |
Characterization of titanium surfaces for dental implants with inorganic contaminant |
spellingShingle |
Characterization of titanium surfaces for dental implants with inorganic contaminant Diniz,Marilia Garcia Titanium Dental implants Aluminum oxide Image processing, computer-assisted |
title_short |
Characterization of titanium surfaces for dental implants with inorganic contaminant |
title_full |
Characterization of titanium surfaces for dental implants with inorganic contaminant |
title_fullStr |
Characterization of titanium surfaces for dental implants with inorganic contaminant |
title_full_unstemmed |
Characterization of titanium surfaces for dental implants with inorganic contaminant |
title_sort |
Characterization of titanium surfaces for dental implants with inorganic contaminant |
author |
Diniz,Marilia Garcia |
author_facet |
Diniz,Marilia Garcia Pinheiro,Marco Antonio Santos Andrade Junior,Antonio Carlos Canabarro Fischer,Ricardo Guimarães |
author_role |
author |
author2 |
Pinheiro,Marco Antonio Santos Andrade Junior,Antonio Carlos Canabarro Fischer,Ricardo Guimarães |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Diniz,Marilia Garcia Pinheiro,Marco Antonio Santos Andrade Junior,Antonio Carlos Canabarro Fischer,Ricardo Guimarães |
dc.subject.por.fl_str_mv |
Titanium Dental implants Aluminum oxide Image processing, computer-assisted |
topic |
Titanium Dental implants Aluminum oxide Image processing, computer-assisted |
description |
The aim of this research was to characterize titanium surfaces blasted with aluminum oxide (Al2O3) particles using the KS 400 digital image processing program. Samples of grade II titanium plates were submitted to blasting processes using particles of Al2O3, and treated with a hydrofluoric acid-based solution. Three digital images from each sample surface were obtained using Scanning Electron Microscopy, and half-quantitative chemical analyses were subsequently performed using Electron Dispersive Spectroscopy (EDS). In addition, parameters related to the alumina phase, such as the concentration level, the area and perimeter of the particles and their circular form factor were measured using KS 400. The mechanical/chemical treatment caused depressions up to 10 µm on homogeneous surfaces. Although the chemical attack significantly removed the alumina phase, residual particles could still be identified by the EDS. The average area occupied by the alumina phase on the samples surfaces was 469.32 (± 284.98) µm², the particle average perimeter was 81.61 (± 27.68) µm, and the mean circular form factor was 0.60 (± 0.05). Characterizing the titanium surface is essential in the evaluation of the material manufacturing process because the presence of residual aluminum particles may have deleterious effects on the formation of the osseous/implant tissue. |
publishDate |
2005 |
dc.date.none.fl_str_mv |
2005-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242005000200006 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242005000200006 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1806-83242005000200006 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
dc.source.none.fl_str_mv |
Brazilian Oral Research v.19 n.2 2005 reponame:Brazilian Oral Research instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO) instacron:SBPQO |
instname_str |
Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
instacron_str |
SBPQO |
institution |
SBPQO |
reponame_str |
Brazilian Oral Research |
collection |
Brazilian Oral Research |
repository.name.fl_str_mv |
Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
repository.mail.fl_str_mv |
pob@edu.usp.br||bor@sbpqo.org.br |
_version_ |
1750318320377135104 |