Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Oral Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000600503 |
Resumo: | This study was conducted to investigate how well cone-beam computed tomography (CBCT) can detect simulated cavitary defects in condyles, and to test the influence of the reconstruction protocols. Defects were created with spherical diamond burs (numbers 1013, 1016, 3017) in superior and/or posterior surfaces of twenty condyles. The condyles were scanned, and cross-sectional reconstructions were performed with nine different protocols, based on slice thickness (0.2, 0.6, 1.0 mm) and on the filters (original image, Sharpen Mild, S9) used. Two observers evaluated the defects, determining their presence and location. Statistical analysis was carried out using simple Kappa coefficient and McNemar's test to check inter- and intra-rater reliability. The chi-square test was used to compare the rater accuracy. Analysis of variance (Tukey's test) assessed the effect of the protocols used. Kappa values for inter- and intra-rater reliability demonstrate almost perfect agreement. The proportion of correct answers was significantly higher than that of errors for cavitary defects on both condyle surfaces (p < 0.01). Only in identifying the defects located on the posterior surface was it possible to observe the influence of the 1.0 mm protocol thickness and no filter, which showed a significantly lower value. Based on the results of the current study, the technique used was valid for identifying the existence of cavities in the condyle surface. However, the protocol of a 1.0 mm-thick slice and no filter proved to be the worst method for identifying the defects on the posterior surface. |
id |
SBPQO-1_480518297d2f444f6453c429198cb0dc |
---|---|
oai_identifier_str |
oai:scielo:S1806-83242013000600503 |
network_acronym_str |
SBPQO-1 |
network_name_str |
Brazilian Oral Research |
repository_id_str |
|
spelling |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomographyMandibular CondyleBone DiseasesCone-Beam Computed TomographyImage EnhancementThis study was conducted to investigate how well cone-beam computed tomography (CBCT) can detect simulated cavitary defects in condyles, and to test the influence of the reconstruction protocols. Defects were created with spherical diamond burs (numbers 1013, 1016, 3017) in superior and/or posterior surfaces of twenty condyles. The condyles were scanned, and cross-sectional reconstructions were performed with nine different protocols, based on slice thickness (0.2, 0.6, 1.0 mm) and on the filters (original image, Sharpen Mild, S9) used. Two observers evaluated the defects, determining their presence and location. Statistical analysis was carried out using simple Kappa coefficient and McNemar's test to check inter- and intra-rater reliability. The chi-square test was used to compare the rater accuracy. Analysis of variance (Tukey's test) assessed the effect of the protocols used. Kappa values for inter- and intra-rater reliability demonstrate almost perfect agreement. The proportion of correct answers was significantly higher than that of errors for cavitary defects on both condyle surfaces (p < 0.01). Only in identifying the defects located on the posterior surface was it possible to observe the influence of the 1.0 mm protocol thickness and no filter, which showed a significantly lower value. Based on the results of the current study, the technique used was valid for identifying the existence of cavities in the condyle surface. However, the protocol of a 1.0 mm-thick slice and no filter proved to be the worst method for identifying the defects on the posterior surface.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2013-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000600503Brazilian Oral Research v.27 n.6 2013reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242013000600010info:eu-repo/semantics/openAccessBastos,Luana CostaCampos,Paulo Sergio FloresRamos-Perez,Flavia Maria de MoraesPontual,Andrea dos AnjosAlmeida,Solange Mariaeng2014-01-09T00:00:00Zoai:scielo:S1806-83242013000600503Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2014-01-09T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false |
dc.title.none.fl_str_mv |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography |
title |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography |
spellingShingle |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography Bastos,Luana Costa Mandibular Condyle Bone Diseases Cone-Beam Computed Tomography Image Enhancement |
title_short |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography |
title_full |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography |
title_fullStr |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography |
title_full_unstemmed |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography |
title_sort |
Evaluation of condyle defects using different reconstruction protocols of cone-beam computed tomography |
author |
Bastos,Luana Costa |
author_facet |
Bastos,Luana Costa Campos,Paulo Sergio Flores Ramos-Perez,Flavia Maria de Moraes Pontual,Andrea dos Anjos Almeida,Solange Maria |
author_role |
author |
author2 |
Campos,Paulo Sergio Flores Ramos-Perez,Flavia Maria de Moraes Pontual,Andrea dos Anjos Almeida,Solange Maria |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Bastos,Luana Costa Campos,Paulo Sergio Flores Ramos-Perez,Flavia Maria de Moraes Pontual,Andrea dos Anjos Almeida,Solange Maria |
dc.subject.por.fl_str_mv |
Mandibular Condyle Bone Diseases Cone-Beam Computed Tomography Image Enhancement |
topic |
Mandibular Condyle Bone Diseases Cone-Beam Computed Tomography Image Enhancement |
description |
This study was conducted to investigate how well cone-beam computed tomography (CBCT) can detect simulated cavitary defects in condyles, and to test the influence of the reconstruction protocols. Defects were created with spherical diamond burs (numbers 1013, 1016, 3017) in superior and/or posterior surfaces of twenty condyles. The condyles were scanned, and cross-sectional reconstructions were performed with nine different protocols, based on slice thickness (0.2, 0.6, 1.0 mm) and on the filters (original image, Sharpen Mild, S9) used. Two observers evaluated the defects, determining their presence and location. Statistical analysis was carried out using simple Kappa coefficient and McNemar's test to check inter- and intra-rater reliability. The chi-square test was used to compare the rater accuracy. Analysis of variance (Tukey's test) assessed the effect of the protocols used. Kappa values for inter- and intra-rater reliability demonstrate almost perfect agreement. The proportion of correct answers was significantly higher than that of errors for cavitary defects on both condyle surfaces (p < 0.01). Only in identifying the defects located on the posterior surface was it possible to observe the influence of the 1.0 mm protocol thickness and no filter, which showed a significantly lower value. Based on the results of the current study, the technique used was valid for identifying the existence of cavities in the condyle surface. However, the protocol of a 1.0 mm-thick slice and no filter proved to be the worst method for identifying the defects on the posterior surface. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000600503 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000600503 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1806-83242013000600010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
dc.source.none.fl_str_mv |
Brazilian Oral Research v.27 n.6 2013 reponame:Brazilian Oral Research instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO) instacron:SBPQO |
instname_str |
Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
instacron_str |
SBPQO |
institution |
SBPQO |
reponame_str |
Brazilian Oral Research |
collection |
Brazilian Oral Research |
repository.name.fl_str_mv |
Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
repository.mail.fl_str_mv |
pob@edu.usp.br||bor@sbpqo.org.br |
_version_ |
1750318323436879872 |