Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units

Detalhes bibliográficos
Autor(a) principal: Micali,Bianca
Data de Publicação: 2004
Outros Autores: Basting,Roberta Tarkany
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300016
Resumo: The clinical performance of composite resins is greatly influenced by the quality of the light-curing unit used. The aim of this study was to compare the efficiency of a commercial light-emitting diode (LED) with that of a halogen-based light-curing unit by means of dye penetration of a micro hybrid composite resin. The composite resin evaluated was Filtek Z250 (3M Dental). The composite was filled into acrylic moulds that were randomly polymerized for 40 seconds by each of the light-emitting systems: light-emitting diode Ultraled (Dabi Atlante) or halogen light Degulux (Degussa Hüls) curing units. Immediately after polymerization, each specimen was individually immersed in 1 ml of 2% methylene blue solution at 37°C ± 2°C. After 24 hours, the specimens were rinsed under running distilled water for 1 minute and stored at 37°C ± 2°C at relative humidity for 24 hours. The composite resins were removed from the moulds and individually triturated before being immersed in new test tubes containing 1 ml of absolute alcohol for 24 hours. The solutions were filtered and centrifuged for 3 minutes at 4,000 rpm and the supernatant was used to determine absorbance in a spectrophotometer at 590 nm. To verify the differences between groups polymerized by LED or halogen light t-test was applied. No significant differences were found between composite resins light-cured by LED or halogen light-curing unit (p > 0.05). The commercially LED-based light-curing unit is as effective to polymerize hybrid composite resins as the halogen-based unit.
id SBPQO-1_65c17be753df1343cb391de43e68a5d2
oai_identifier_str oai:scielo:S1806-83242004000300016
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing unitsComposite resinsSpectrophotometryThe clinical performance of composite resins is greatly influenced by the quality of the light-curing unit used. The aim of this study was to compare the efficiency of a commercial light-emitting diode (LED) with that of a halogen-based light-curing unit by means of dye penetration of a micro hybrid composite resin. The composite resin evaluated was Filtek Z250 (3M Dental). The composite was filled into acrylic moulds that were randomly polymerized for 40 seconds by each of the light-emitting systems: light-emitting diode Ultraled (Dabi Atlante) or halogen light Degulux (Degussa Hüls) curing units. Immediately after polymerization, each specimen was individually immersed in 1 ml of 2% methylene blue solution at 37°C ± 2°C. After 24 hours, the specimens were rinsed under running distilled water for 1 minute and stored at 37°C ± 2°C at relative humidity for 24 hours. The composite resins were removed from the moulds and individually triturated before being immersed in new test tubes containing 1 ml of absolute alcohol for 24 hours. The solutions were filtered and centrifuged for 3 minutes at 4,000 rpm and the supernatant was used to determine absorbance in a spectrophotometer at 590 nm. To verify the differences between groups polymerized by LED or halogen light t-test was applied. No significant differences were found between composite resins light-cured by LED or halogen light-curing unit (p > 0.05). The commercially LED-based light-curing unit is as effective to polymerize hybrid composite resins as the halogen-based unit.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2004-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300016Brazilian Oral Research v.18 n.3 2004reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242004000300016info:eu-repo/semantics/openAccessMicali,BiancaBasting,Roberta Tarkanyeng2004-09-29T00:00:00Zoai:scielo:S1806-83242004000300016Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2004-09-29T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
title Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
spellingShingle Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
Micali,Bianca
Composite resins
Spectrophotometry
title_short Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
title_full Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
title_fullStr Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
title_full_unstemmed Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
title_sort Effectiveness of composite resin polymerization using light-emitting diodes (LEDs) or halogen-based light-curing units
author Micali,Bianca
author_facet Micali,Bianca
Basting,Roberta Tarkany
author_role author
author2 Basting,Roberta Tarkany
author2_role author
dc.contributor.author.fl_str_mv Micali,Bianca
Basting,Roberta Tarkany
dc.subject.por.fl_str_mv Composite resins
Spectrophotometry
topic Composite resins
Spectrophotometry
description The clinical performance of composite resins is greatly influenced by the quality of the light-curing unit used. The aim of this study was to compare the efficiency of a commercial light-emitting diode (LED) with that of a halogen-based light-curing unit by means of dye penetration of a micro hybrid composite resin. The composite resin evaluated was Filtek Z250 (3M Dental). The composite was filled into acrylic moulds that were randomly polymerized for 40 seconds by each of the light-emitting systems: light-emitting diode Ultraled (Dabi Atlante) or halogen light Degulux (Degussa Hüls) curing units. Immediately after polymerization, each specimen was individually immersed in 1 ml of 2% methylene blue solution at 37°C ± 2°C. After 24 hours, the specimens were rinsed under running distilled water for 1 minute and stored at 37°C ± 2°C at relative humidity for 24 hours. The composite resins were removed from the moulds and individually triturated before being immersed in new test tubes containing 1 ml of absolute alcohol for 24 hours. The solutions were filtered and centrifuged for 3 minutes at 4,000 rpm and the supernatant was used to determine absorbance in a spectrophotometer at 590 nm. To verify the differences between groups polymerized by LED or halogen light t-test was applied. No significant differences were found between composite resins light-cured by LED or halogen light-curing unit (p > 0.05). The commercially LED-based light-curing unit is as effective to polymerize hybrid composite resins as the halogen-based unit.
publishDate 2004
dc.date.none.fl_str_mv 2004-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300016
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300016
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242004000300016
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.18 n.3 2004
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318320326803456