Assessment of open source software for CBCT in detecting additional mental foramina

Detalhes bibliográficos
Autor(a) principal: Santos Junior,Oséas
Data de Publicação: 2013
Outros Autores: Pinheiro,Lucas Rodrigues, Umetsubo,Otávio Shoiti, Sales,Marcelo Augusto Oliveira, Cavalcanti,Marcelo Gusmão Paraíso
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200128
Resumo: The purpose of this study was to evaluate which post-processing imaging protocol would be better to analyze the additional mental foramen (AMF) in preoperative planning with cone-beam computed tomography (CBCT) exams, and to test reproducibility of measurements, using open source software (OsiriX). The software was used to detect the cases of AMF from among 58 exams for dental implant planning in edentulous mandible areas-three cases were found. The case images were submitted to qualitative analysis using 2D orthogonal MPR, 3D-MPR and 3D volume rendering protocols by two oral and maxillofacial radiologists. Quantitative analysis used the 3D-MPR protocol; the closed polygon tool measured the mental foramen (MF) and the AMF areas; the length tool measured the distance between foramina. The measurements were performed independently by the examiners, at two different times. Intra- and interexaminer agreement was assessed using the intraclass correlation coefficient. The panoramic view did not show the MF and the AMF clearly. The AMF could be detected in the parasagittal view. 2D Orthogonal MPR was effective to observe the AMF in some cases. The 3D-MPR and 3D view protocols were the most effective to locate and analyze the AMF. In conclusion, a 3D view improves visualization when anatomical points are not clearly visible. 3D-MPR was considered a more effective post-processing imaging protocol to observe foramina relationships. The high reproducibility of measurements for anatomical MF variations was established using specific tools featured in open source software for CBCT. OsiriX is realistic and recommended for preoperative planning.
id SBPQO-1_8d4278c1601af2f4b20652adf9f441c9
oai_identifier_str oai:scielo:S1806-83242013000200128
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Assessment of open source software for CBCT in detecting additional mental foraminaCone Beam Computed TomographyImaging, Three-DimensionalMandibleTomography, X-Ray ComputedThe purpose of this study was to evaluate which post-processing imaging protocol would be better to analyze the additional mental foramen (AMF) in preoperative planning with cone-beam computed tomography (CBCT) exams, and to test reproducibility of measurements, using open source software (OsiriX). The software was used to detect the cases of AMF from among 58 exams for dental implant planning in edentulous mandible areas-three cases were found. The case images were submitted to qualitative analysis using 2D orthogonal MPR, 3D-MPR and 3D volume rendering protocols by two oral and maxillofacial radiologists. Quantitative analysis used the 3D-MPR protocol; the closed polygon tool measured the mental foramen (MF) and the AMF areas; the length tool measured the distance between foramina. The measurements were performed independently by the examiners, at two different times. Intra- and interexaminer agreement was assessed using the intraclass correlation coefficient. The panoramic view did not show the MF and the AMF clearly. The AMF could be detected in the parasagittal view. 2D Orthogonal MPR was effective to observe the AMF in some cases. The 3D-MPR and 3D view protocols were the most effective to locate and analyze the AMF. In conclusion, a 3D view improves visualization when anatomical points are not clearly visible. 3D-MPR was considered a more effective post-processing imaging protocol to observe foramina relationships. The high reproducibility of measurements for anatomical MF variations was established using specific tools featured in open source software for CBCT. OsiriX is realistic and recommended for preoperative planning.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2013-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200128Brazilian Oral Research v.27 n.2 2013reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242013005000003info:eu-repo/semantics/openAccessSantos Junior,OséasPinheiro,Lucas RodriguesUmetsubo,Otávio ShoitiSales,Marcelo Augusto OliveiraCavalcanti,Marcelo Gusmão Paraísoeng2013-05-28T00:00:00Zoai:scielo:S1806-83242013000200128Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2013-05-28T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Assessment of open source software for CBCT in detecting additional mental foramina
title Assessment of open source software for CBCT in detecting additional mental foramina
spellingShingle Assessment of open source software for CBCT in detecting additional mental foramina
Santos Junior,Oséas
Cone Beam Computed Tomography
Imaging, Three-Dimensional
Mandible
Tomography, X-Ray Computed
title_short Assessment of open source software for CBCT in detecting additional mental foramina
title_full Assessment of open source software for CBCT in detecting additional mental foramina
title_fullStr Assessment of open source software for CBCT in detecting additional mental foramina
title_full_unstemmed Assessment of open source software for CBCT in detecting additional mental foramina
title_sort Assessment of open source software for CBCT in detecting additional mental foramina
author Santos Junior,Oséas
author_facet Santos Junior,Oséas
Pinheiro,Lucas Rodrigues
Umetsubo,Otávio Shoiti
Sales,Marcelo Augusto Oliveira
Cavalcanti,Marcelo Gusmão Paraíso
author_role author
author2 Pinheiro,Lucas Rodrigues
Umetsubo,Otávio Shoiti
Sales,Marcelo Augusto Oliveira
Cavalcanti,Marcelo Gusmão Paraíso
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Santos Junior,Oséas
Pinheiro,Lucas Rodrigues
Umetsubo,Otávio Shoiti
Sales,Marcelo Augusto Oliveira
Cavalcanti,Marcelo Gusmão Paraíso
dc.subject.por.fl_str_mv Cone Beam Computed Tomography
Imaging, Three-Dimensional
Mandible
Tomography, X-Ray Computed
topic Cone Beam Computed Tomography
Imaging, Three-Dimensional
Mandible
Tomography, X-Ray Computed
description The purpose of this study was to evaluate which post-processing imaging protocol would be better to analyze the additional mental foramen (AMF) in preoperative planning with cone-beam computed tomography (CBCT) exams, and to test reproducibility of measurements, using open source software (OsiriX). The software was used to detect the cases of AMF from among 58 exams for dental implant planning in edentulous mandible areas-three cases were found. The case images were submitted to qualitative analysis using 2D orthogonal MPR, 3D-MPR and 3D volume rendering protocols by two oral and maxillofacial radiologists. Quantitative analysis used the 3D-MPR protocol; the closed polygon tool measured the mental foramen (MF) and the AMF areas; the length tool measured the distance between foramina. The measurements were performed independently by the examiners, at two different times. Intra- and interexaminer agreement was assessed using the intraclass correlation coefficient. The panoramic view did not show the MF and the AMF clearly. The AMF could be detected in the parasagittal view. 2D Orthogonal MPR was effective to observe the AMF in some cases. The 3D-MPR and 3D view protocols were the most effective to locate and analyze the AMF. In conclusion, a 3D view improves visualization when anatomical points are not clearly visible. 3D-MPR was considered a more effective post-processing imaging protocol to observe foramina relationships. The high reproducibility of measurements for anatomical MF variations was established using specific tools featured in open source software for CBCT. OsiriX is realistic and recommended for preoperative planning.
publishDate 2013
dc.date.none.fl_str_mv 2013-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200128
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200128
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242013005000003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.27 n.2 2013
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318323455754240