Evaluation of mechanical properties of five cements for orthodontic band cementation

Detalhes bibliográficos
Autor(a) principal: Aguiar,Diego Andrei
Data de Publicação: 2013
Outros Autores: Ritter,Daltro Enéas, Rocha,Roberto, Locks,Arno, Borgatto,Adriano Ferreti
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200136
Resumo: The aim of this in vitro study was to compare the flexural, compressive and diametral tensile strengths of five cements used in orthodontics for band cementation. Twelve specimens of each cement were tested: 1 - GC Fuji Ortho Band (FJ), GC America Inc.; 2 - Meron (MR), Voco; 3 - Multi-Cure Glass Ionomer Band Cement (MC), 3M Unitek; 4 - Band-Lok (BL), Reliance Orthodontic Products; and 5 - Ketac Cem (KC), 3M ESPE. The results (mean) for diametral tensile strength were: 10.51 MPa (FJ), 9.60 MPa (MR), 20.04 MPa (MC), 42.80 MPa (BL), and 4.08 MPa (KC). The results for compressive strength were (in the same order): 64.50 MPa, 77.71 MPa, 94.21 MPa, 193.88 MPa, and 81.93 MPa. The results for flexural strength were (in the same order): 20.72 MPa, 25.84 MPa, 53.41 MPa, 137.41 MPa, and 20.50 MPa. The statistical analysis was performed by two-way ANOVA and Tukey tests with p-value £ 0.05. In terms of diametral tensile strength, BL showed the highest strength statistically, and MC, the second highest. In terms of compressive tensile strength, BL showed the highest strength statistically, and FJ did not attain the minimum recommended strength. In terms of flexural tensile strength, BL cement was superior to MC, and MR, FJ and KC were equivalent and inferior to BL and MC.
id SBPQO-1_97bbd2216500b66135c057411f92a512
oai_identifier_str oai:scielo:S1806-83242013000200136
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Evaluation of mechanical properties of five cements for orthodontic band cementationBasic ResearchDental MaterialsDental CementsThe aim of this in vitro study was to compare the flexural, compressive and diametral tensile strengths of five cements used in orthodontics for band cementation. Twelve specimens of each cement were tested: 1 - GC Fuji Ortho Band (FJ), GC America Inc.; 2 - Meron (MR), Voco; 3 - Multi-Cure Glass Ionomer Band Cement (MC), 3M Unitek; 4 - Band-Lok (BL), Reliance Orthodontic Products; and 5 - Ketac Cem (KC), 3M ESPE. The results (mean) for diametral tensile strength were: 10.51 MPa (FJ), 9.60 MPa (MR), 20.04 MPa (MC), 42.80 MPa (BL), and 4.08 MPa (KC). The results for compressive strength were (in the same order): 64.50 MPa, 77.71 MPa, 94.21 MPa, 193.88 MPa, and 81.93 MPa. The results for flexural strength were (in the same order): 20.72 MPa, 25.84 MPa, 53.41 MPa, 137.41 MPa, and 20.50 MPa. The statistical analysis was performed by two-way ANOVA and Tukey tests with p-value £ 0.05. In terms of diametral tensile strength, BL showed the highest strength statistically, and MC, the second highest. In terms of compressive tensile strength, BL showed the highest strength statistically, and FJ did not attain the minimum recommended strength. In terms of flexural tensile strength, BL cement was superior to MC, and MR, FJ and KC were equivalent and inferior to BL and MC.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2013-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200136Brazilian Oral Research v.27 n.2 2013reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242013005000002info:eu-repo/semantics/openAccessAguiar,Diego AndreiRitter,Daltro EnéasRocha,RobertoLocks,ArnoBorgatto,Adriano Ferretieng2013-05-28T00:00:00Zoai:scielo:S1806-83242013000200136Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2013-05-28T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Evaluation of mechanical properties of five cements for orthodontic band cementation
title Evaluation of mechanical properties of five cements for orthodontic band cementation
spellingShingle Evaluation of mechanical properties of five cements for orthodontic band cementation
Aguiar,Diego Andrei
Basic Research
Dental Materials
Dental Cements
title_short Evaluation of mechanical properties of five cements for orthodontic band cementation
title_full Evaluation of mechanical properties of five cements for orthodontic band cementation
title_fullStr Evaluation of mechanical properties of five cements for orthodontic band cementation
title_full_unstemmed Evaluation of mechanical properties of five cements for orthodontic band cementation
title_sort Evaluation of mechanical properties of five cements for orthodontic band cementation
author Aguiar,Diego Andrei
author_facet Aguiar,Diego Andrei
Ritter,Daltro Enéas
Rocha,Roberto
Locks,Arno
Borgatto,Adriano Ferreti
author_role author
author2 Ritter,Daltro Enéas
Rocha,Roberto
Locks,Arno
Borgatto,Adriano Ferreti
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Aguiar,Diego Andrei
Ritter,Daltro Enéas
Rocha,Roberto
Locks,Arno
Borgatto,Adriano Ferreti
dc.subject.por.fl_str_mv Basic Research
Dental Materials
Dental Cements
topic Basic Research
Dental Materials
Dental Cements
description The aim of this in vitro study was to compare the flexural, compressive and diametral tensile strengths of five cements used in orthodontics for band cementation. Twelve specimens of each cement were tested: 1 - GC Fuji Ortho Band (FJ), GC America Inc.; 2 - Meron (MR), Voco; 3 - Multi-Cure Glass Ionomer Band Cement (MC), 3M Unitek; 4 - Band-Lok (BL), Reliance Orthodontic Products; and 5 - Ketac Cem (KC), 3M ESPE. The results (mean) for diametral tensile strength were: 10.51 MPa (FJ), 9.60 MPa (MR), 20.04 MPa (MC), 42.80 MPa (BL), and 4.08 MPa (KC). The results for compressive strength were (in the same order): 64.50 MPa, 77.71 MPa, 94.21 MPa, 193.88 MPa, and 81.93 MPa. The results for flexural strength were (in the same order): 20.72 MPa, 25.84 MPa, 53.41 MPa, 137.41 MPa, and 20.50 MPa. The statistical analysis was performed by two-way ANOVA and Tukey tests with p-value £ 0.05. In terms of diametral tensile strength, BL showed the highest strength statistically, and MC, the second highest. In terms of compressive tensile strength, BL showed the highest strength statistically, and FJ did not attain the minimum recommended strength. In terms of flexural tensile strength, BL cement was superior to MC, and MR, FJ and KC were equivalent and inferior to BL and MC.
publishDate 2013
dc.date.none.fl_str_mv 2013-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200136
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000200136
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242013005000002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.27 n.2 2013
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318323463094272