A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Oral Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100229 |
Resumo: | Abstract To compare the shaping ability of different single-file systems in the preparation of mesial curved canals of mandibular molars using micro-CT technology. Fifteen mesial roots of mandibular molars with two independent and curved canals (n = 30) were selected, scanned at a resolution of 26.7 μm anatomically matched, and distributed into three groups (n = 10), according to the preparation system: WaveOne 25.08, Reciproc 25.08, and OneShape 25.06. A final micro-CT scanning was performed, data sets were registered with their respective counterparts, and compared regarding the three-dimensional (volume, surface area, and structure model index - SMI) and two-dimensional (perimeter, area, roundness, major and minor diameters) parameters, as well as, canal transportation, using ANOVA and post hoc Tukey tests (α = 5%). Overall, no difference was observed between groups regarding area, perimeter, volume, surface area, and canal transportation (p > 0.05). Within group, no canal transportation was significantly higherobserved in the apical third (0.10 ± 0.05 mm) compared to coronal (0.08±0.040 mm) and middle (0.07 ± 0.03 mm) thirds (p < 0.05). Structure model index (SMI) was statistically higher after preparation with OneShape instrument (0.36 ± 0.26) compared to other systems (p < 0.05). Within the parameters of this study, similar shaping ability was observed in the preparation of mesial curved root canals of mandibular molars with Reciproc, OneShape and WaveOne systems. |
id |
SBPQO-1_9afb679726723b60aff62dca5970525a |
---|---|
oai_identifier_str |
oai:scielo:S1806-83242020000100229 |
network_acronym_str |
SBPQO-1 |
network_name_str |
Brazilian Oral Research |
repository_id_str |
|
spelling |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canalsAbstract To compare the shaping ability of different single-file systems in the preparation of mesial curved canals of mandibular molars using micro-CT technology. Fifteen mesial roots of mandibular molars with two independent and curved canals (n = 30) were selected, scanned at a resolution of 26.7 μm anatomically matched, and distributed into three groups (n = 10), according to the preparation system: WaveOne 25.08, Reciproc 25.08, and OneShape 25.06. A final micro-CT scanning was performed, data sets were registered with their respective counterparts, and compared regarding the three-dimensional (volume, surface area, and structure model index - SMI) and two-dimensional (perimeter, area, roundness, major and minor diameters) parameters, as well as, canal transportation, using ANOVA and post hoc Tukey tests (α = 5%). Overall, no difference was observed between groups regarding area, perimeter, volume, surface area, and canal transportation (p > 0.05). Within group, no canal transportation was significantly higherobserved in the apical third (0.10 ± 0.05 mm) compared to coronal (0.08±0.040 mm) and middle (0.07 ± 0.03 mm) thirds (p < 0.05). Structure model index (SMI) was statistically higher after preparation with OneShape instrument (0.36 ± 0.26) compared to other systems (p < 0.05). Within the parameters of this study, similar shaping ability was observed in the preparation of mesial curved root canals of mandibular molars with Reciproc, OneShape and WaveOne systems.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100229Brazilian Oral Research v.34 2020reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/1807-3107bor-2020.vol34.0039info:eu-repo/semantics/openAccessSOUSA-NETO,Manoel DamiãoCROZETA,Bruno MonguilhottLOPES,Fabiane CarneiroMAZZI-CHAVES,Jardel FranciscoPEREIRA,Rodrigo DantasSILVA-SOUSA,Alice CorrêaAMARAL,Mariana Carvalho de AndradeSTEIER,LiviuJACOBS,ReinhildeSILVA-SOUSA,Yara Teresinha Corrêaeng2020-04-27T00:00:00Zoai:scielo:S1806-83242020000100229Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2020-04-27T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false |
dc.title.none.fl_str_mv |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals |
title |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals |
spellingShingle |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals SOUSA-NETO,Manoel Damião |
title_short |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals |
title_full |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals |
title_fullStr |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals |
title_full_unstemmed |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals |
title_sort |
A micro-CT evaluation of the performance of rotary and reciprocating single-file systems in shaping ability of curved root canals |
author |
SOUSA-NETO,Manoel Damião |
author_facet |
SOUSA-NETO,Manoel Damião CROZETA,Bruno Monguilhott LOPES,Fabiane Carneiro MAZZI-CHAVES,Jardel Francisco PEREIRA,Rodrigo Dantas SILVA-SOUSA,Alice Corrêa AMARAL,Mariana Carvalho de Andrade STEIER,Liviu JACOBS,Reinhilde SILVA-SOUSA,Yara Teresinha Corrêa |
author_role |
author |
author2 |
CROZETA,Bruno Monguilhott LOPES,Fabiane Carneiro MAZZI-CHAVES,Jardel Francisco PEREIRA,Rodrigo Dantas SILVA-SOUSA,Alice Corrêa AMARAL,Mariana Carvalho de Andrade STEIER,Liviu JACOBS,Reinhilde SILVA-SOUSA,Yara Teresinha Corrêa |
author2_role |
author author author author author author author author author |
dc.contributor.author.fl_str_mv |
SOUSA-NETO,Manoel Damião CROZETA,Bruno Monguilhott LOPES,Fabiane Carneiro MAZZI-CHAVES,Jardel Francisco PEREIRA,Rodrigo Dantas SILVA-SOUSA,Alice Corrêa AMARAL,Mariana Carvalho de Andrade STEIER,Liviu JACOBS,Reinhilde SILVA-SOUSA,Yara Teresinha Corrêa |
description |
Abstract To compare the shaping ability of different single-file systems in the preparation of mesial curved canals of mandibular molars using micro-CT technology. Fifteen mesial roots of mandibular molars with two independent and curved canals (n = 30) were selected, scanned at a resolution of 26.7 μm anatomically matched, and distributed into three groups (n = 10), according to the preparation system: WaveOne 25.08, Reciproc 25.08, and OneShape 25.06. A final micro-CT scanning was performed, data sets were registered with their respective counterparts, and compared regarding the three-dimensional (volume, surface area, and structure model index - SMI) and two-dimensional (perimeter, area, roundness, major and minor diameters) parameters, as well as, canal transportation, using ANOVA and post hoc Tukey tests (α = 5%). Overall, no difference was observed between groups regarding area, perimeter, volume, surface area, and canal transportation (p > 0.05). Within group, no canal transportation was significantly higherobserved in the apical third (0.10 ± 0.05 mm) compared to coronal (0.08±0.040 mm) and middle (0.07 ± 0.03 mm) thirds (p < 0.05). Structure model index (SMI) was statistically higher after preparation with OneShape instrument (0.36 ± 0.26) compared to other systems (p < 0.05). Within the parameters of this study, similar shaping ability was observed in the preparation of mesial curved root canals of mandibular molars with Reciproc, OneShape and WaveOne systems. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100229 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100229 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1807-3107bor-2020.vol34.0039 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
dc.source.none.fl_str_mv |
Brazilian Oral Research v.34 2020 reponame:Brazilian Oral Research instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO) instacron:SBPQO |
instname_str |
Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
instacron_str |
SBPQO |
institution |
SBPQO |
reponame_str |
Brazilian Oral Research |
collection |
Brazilian Oral Research |
repository.name.fl_str_mv |
Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
repository.mail.fl_str_mv |
pob@edu.usp.br||bor@sbpqo.org.br |
_version_ |
1750318327058661376 |