Mechanical influence of thread pitch on orthodontic mini-implant stability

Detalhes bibliográficos
Autor(a) principal: CUNHA,Amanda Carneiro da
Data de Publicação: 2015
Outros Autores: FREITAS,Amanda Osório Ayres de, MARQUEZAN,Mariana, NOJIMA,Lincoln Issamu
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100231
Resumo: The aim of this study was to evaluate the effect of pitch distance on the primary stability (PS) of orthodontic mini-implants (MIs) in artificial bone. Twenty experimental MIs were allocated to two groups, according to their geometric design: G1(30oX 0.6 mm) and G2(45o X 0.8 mm), and inserted into artificial bone of different densities: D1 (0.32 g/cm3) and D2 (0.64 g/cm3). The maximum insertion torque (IT) and removal torque (RT) values were recorded in N.cm. Loss of torque (LT) values were obtained by calculating the difference between the IT and RT. MI mobility was measured by means of a Periotest assessment. Normality and homogeneity were determined by means of the Kolmogorov-Smirnov and Shapiro-Wilk tests, respectively. A two-way ANOVA was used to detect differences between the mini-implant design and density factors. The ANOVA/Tukey tests were used to determine the intergroup difference. Higher IT values were observed for G2 (p ≤ 0.05) in D2. No statistical difference for RT was observed between the groups, whereas G2 presented higher values only for LT (p ≤ 0.05). The Periotest values (PTV) were higher for G1, in comparison with G2, in D1. G1 presented better PS in D2 (IT, RT and LT), whereas G2 was found to be more stable in D1, after evaluation with Periotest.
id SBPQO-1_d44a079195e42a5829fbaf89ec2ee0df
oai_identifier_str oai:scielo:S1806-83242015000100231
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Mechanical influence of thread pitch on orthodontic mini-implant stabilityMechanicsOrthodontic Anchorage ProceduresMaterials TestingThe aim of this study was to evaluate the effect of pitch distance on the primary stability (PS) of orthodontic mini-implants (MIs) in artificial bone. Twenty experimental MIs were allocated to two groups, according to their geometric design: G1(30oX 0.6 mm) and G2(45o X 0.8 mm), and inserted into artificial bone of different densities: D1 (0.32 g/cm3) and D2 (0.64 g/cm3). The maximum insertion torque (IT) and removal torque (RT) values were recorded in N.cm. Loss of torque (LT) values were obtained by calculating the difference between the IT and RT. MI mobility was measured by means of a Periotest assessment. Normality and homogeneity were determined by means of the Kolmogorov-Smirnov and Shapiro-Wilk tests, respectively. A two-way ANOVA was used to detect differences between the mini-implant design and density factors. The ANOVA/Tukey tests were used to determine the intergroup difference. Higher IT values were observed for G2 (p ≤ 0.05) in D2. No statistical difference for RT was observed between the groups, whereas G2 presented higher values only for LT (p ≤ 0.05). The Periotest values (PTV) were higher for G1, in comparison with G2, in D1. G1 presented better PS in D2 (IT, RT and LT), whereas G2 was found to be more stable in D1, after evaluation with Periotest.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2015-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100231Brazilian Oral Research v.29 n.1 2015reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/1807-3107BOR-2015.vol29.0042info:eu-repo/semantics/openAccessCUNHA,Amanda Carneiro daFREITAS,Amanda Osório Ayres deMARQUEZAN,MarianaNOJIMA,Lincoln Issamueng2018-09-17T00:00:00Zoai:scielo:S1806-83242015000100231Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2018-09-17T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Mechanical influence of thread pitch on orthodontic mini-implant stability
title Mechanical influence of thread pitch on orthodontic mini-implant stability
spellingShingle Mechanical influence of thread pitch on orthodontic mini-implant stability
CUNHA,Amanda Carneiro da
Mechanics
Orthodontic Anchorage Procedures
Materials Testing
title_short Mechanical influence of thread pitch on orthodontic mini-implant stability
title_full Mechanical influence of thread pitch on orthodontic mini-implant stability
title_fullStr Mechanical influence of thread pitch on orthodontic mini-implant stability
title_full_unstemmed Mechanical influence of thread pitch on orthodontic mini-implant stability
title_sort Mechanical influence of thread pitch on orthodontic mini-implant stability
author CUNHA,Amanda Carneiro da
author_facet CUNHA,Amanda Carneiro da
FREITAS,Amanda Osório Ayres de
MARQUEZAN,Mariana
NOJIMA,Lincoln Issamu
author_role author
author2 FREITAS,Amanda Osório Ayres de
MARQUEZAN,Mariana
NOJIMA,Lincoln Issamu
author2_role author
author
author
dc.contributor.author.fl_str_mv CUNHA,Amanda Carneiro da
FREITAS,Amanda Osório Ayres de
MARQUEZAN,Mariana
NOJIMA,Lincoln Issamu
dc.subject.por.fl_str_mv Mechanics
Orthodontic Anchorage Procedures
Materials Testing
topic Mechanics
Orthodontic Anchorage Procedures
Materials Testing
description The aim of this study was to evaluate the effect of pitch distance on the primary stability (PS) of orthodontic mini-implants (MIs) in artificial bone. Twenty experimental MIs were allocated to two groups, according to their geometric design: G1(30oX 0.6 mm) and G2(45o X 0.8 mm), and inserted into artificial bone of different densities: D1 (0.32 g/cm3) and D2 (0.64 g/cm3). The maximum insertion torque (IT) and removal torque (RT) values were recorded in N.cm. Loss of torque (LT) values were obtained by calculating the difference between the IT and RT. MI mobility was measured by means of a Periotest assessment. Normality and homogeneity were determined by means of the Kolmogorov-Smirnov and Shapiro-Wilk tests, respectively. A two-way ANOVA was used to detect differences between the mini-implant design and density factors. The ANOVA/Tukey tests were used to determine the intergroup difference. Higher IT values were observed for G2 (p ≤ 0.05) in D2. No statistical difference for RT was observed between the groups, whereas G2 presented higher values only for LT (p ≤ 0.05). The Periotest values (PTV) were higher for G1, in comparison with G2, in D1. G1 presented better PS in D2 (IT, RT and LT), whereas G2 was found to be more stable in D1, after evaluation with Periotest.
publishDate 2015
dc.date.none.fl_str_mv 2015-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100231
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100231
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-3107BOR-2015.vol29.0042
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.29 n.1 2015
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318324212826112