Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics

Detalhes bibliográficos
Autor(a) principal: TAVARES,Lucas do Nascimento
Data de Publicação: 2020
Outros Autores: ZANCOPÉ,Karla, SILVA,Anielle Christine Almeida, RAPOSO,Luís Henrique Araújo, SOARES,Carlos José, NEVES,Flávio Domingues das
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100202
Resumo: Abstract The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.
id SBPQO-1_dcc28fec1f7f17bf95c52534cbfafc62
oai_identifier_str oai:scielo:S1806-83242020000100202
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramicsCeramicsDental MaterialsComputer-Aided DesignAbstract The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100202Brazilian Oral Research v.34 2020reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/1807-3107bor-2020.vol34.0004info:eu-repo/semantics/openAccessTAVARES,Lucas do NascimentoZANCOPÉ,KarlaSILVA,Anielle Christine AlmeidaRAPOSO,Luís Henrique AraújoSOARES,Carlos JoséNEVES,Flávio Domingues daseng2020-01-28T00:00:00Zoai:scielo:S1806-83242020000100202Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2020-01-28T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
title Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
spellingShingle Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
TAVARES,Lucas do Nascimento
Ceramics
Dental Materials
Computer-Aided Design
title_short Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
title_full Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
title_fullStr Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
title_full_unstemmed Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
title_sort Microstructural and mechanical analysis of two CAD-CAM lithium disilicate glass-reinforced ceramics
author TAVARES,Lucas do Nascimento
author_facet TAVARES,Lucas do Nascimento
ZANCOPÉ,Karla
SILVA,Anielle Christine Almeida
RAPOSO,Luís Henrique Araújo
SOARES,Carlos José
NEVES,Flávio Domingues das
author_role author
author2 ZANCOPÉ,Karla
SILVA,Anielle Christine Almeida
RAPOSO,Luís Henrique Araújo
SOARES,Carlos José
NEVES,Flávio Domingues das
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv TAVARES,Lucas do Nascimento
ZANCOPÉ,Karla
SILVA,Anielle Christine Almeida
RAPOSO,Luís Henrique Araújo
SOARES,Carlos José
NEVES,Flávio Domingues das
dc.subject.por.fl_str_mv Ceramics
Dental Materials
Computer-Aided Design
topic Ceramics
Dental Materials
Computer-Aided Design
description Abstract The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100202
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242020000100202
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1807-3107bor-2020.vol34.0004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.34 2020
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318326718922752