Bonding stability of adhesive systems to eroded dentin
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Oral Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100284 |
Resumo: | This in vitrostudy evaluated the immediate and 6 months microshear bond strength (µSBS) of different adhesive systems to sound and eroded dentin. Sixty bovine incisors were embedded in acrylic resin and ground to obtain flat buccal dentin surfaces. Specimens were randomly allocated into two groups: sound dentin (immersion in artificial saliva) and eroded dentin (erosive challenge following a pH cycling model comprising 4 ×/day Sprite Light® drink for 10 days). Then, specimens were reassigned according to the adhesive system: etch-and-rinse adhesive (Adper Single Bond), two-step self-etch system (Clearfil SE Bond), or one-step self-etch adhesive (Adper Easy One). Polyethylene tubes with an internal diameter of 0.76 mm were placed over pre-treated dentin and filled with resin composite (Z250). Half of the specimens were evaluated by the µSBS test after 24 h, and the other half 6 months later, after water storage at 37°C. Failure mode was evaluated using a stereomicroscope (400×). Data were analyzed by three-way repeated measures analysis of variance and Tukey’s post hoc tests (α = 0.05). After 6 months of water aging, marked reductions in µSBS values were observed, irrespective of the substrate. The µSBS values for eroded dentin were lower than those obtained for sound dentin. No difference in bonding effectiveness was observed among adhesive systems. For all groups, adhesive/mixed failure was observed. In conclusion, eroded dentin compromises the bonding quality of adhesive systems over time. |
id |
SBPQO-1_e527fd38037f8434cfb7f89b3474ceec |
---|---|
oai_identifier_str |
oai:scielo:S1806-83242015000100284 |
network_acronym_str |
SBPQO-1 |
network_name_str |
Brazilian Oral Research |
repository_id_str |
|
spelling |
Bonding stability of adhesive systems to eroded dentinTooth ErosionDentin-Bonding AgentsShear StrengthThis in vitrostudy evaluated the immediate and 6 months microshear bond strength (µSBS) of different adhesive systems to sound and eroded dentin. Sixty bovine incisors were embedded in acrylic resin and ground to obtain flat buccal dentin surfaces. Specimens were randomly allocated into two groups: sound dentin (immersion in artificial saliva) and eroded dentin (erosive challenge following a pH cycling model comprising 4 ×/day Sprite Light® drink for 10 days). Then, specimens were reassigned according to the adhesive system: etch-and-rinse adhesive (Adper Single Bond), two-step self-etch system (Clearfil SE Bond), or one-step self-etch adhesive (Adper Easy One). Polyethylene tubes with an internal diameter of 0.76 mm were placed over pre-treated dentin and filled with resin composite (Z250). Half of the specimens were evaluated by the µSBS test after 24 h, and the other half 6 months later, after water storage at 37°C. Failure mode was evaluated using a stereomicroscope (400×). Data were analyzed by three-way repeated measures analysis of variance and Tukey’s post hoc tests (α = 0.05). After 6 months of water aging, marked reductions in µSBS values were observed, irrespective of the substrate. The µSBS values for eroded dentin were lower than those obtained for sound dentin. No difference in bonding effectiveness was observed among adhesive systems. For all groups, adhesive/mixed failure was observed. In conclusion, eroded dentin compromises the bonding quality of adhesive systems over time.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2015-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100284Brazilian Oral Research v.29 n.1 2015reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/1807-3107BOR-2015.vol29.0088info:eu-repo/semantics/openAccessCRUZ,Janaina BarrosBONINI,GabrielaLENZI,Tathiane LarissaIMPARATO,José Carlos PettorossiRAGGIO,Daniela Prócidaeng2018-09-17T00:00:00Zoai:scielo:S1806-83242015000100284Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2018-09-17T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false |
dc.title.none.fl_str_mv |
Bonding stability of adhesive systems to eroded dentin |
title |
Bonding stability of adhesive systems to eroded dentin |
spellingShingle |
Bonding stability of adhesive systems to eroded dentin CRUZ,Janaina Barros Tooth Erosion Dentin-Bonding Agents Shear Strength |
title_short |
Bonding stability of adhesive systems to eroded dentin |
title_full |
Bonding stability of adhesive systems to eroded dentin |
title_fullStr |
Bonding stability of adhesive systems to eroded dentin |
title_full_unstemmed |
Bonding stability of adhesive systems to eroded dentin |
title_sort |
Bonding stability of adhesive systems to eroded dentin |
author |
CRUZ,Janaina Barros |
author_facet |
CRUZ,Janaina Barros BONINI,Gabriela LENZI,Tathiane Larissa IMPARATO,José Carlos Pettorossi RAGGIO,Daniela Prócida |
author_role |
author |
author2 |
BONINI,Gabriela LENZI,Tathiane Larissa IMPARATO,José Carlos Pettorossi RAGGIO,Daniela Prócida |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
CRUZ,Janaina Barros BONINI,Gabriela LENZI,Tathiane Larissa IMPARATO,José Carlos Pettorossi RAGGIO,Daniela Prócida |
dc.subject.por.fl_str_mv |
Tooth Erosion Dentin-Bonding Agents Shear Strength |
topic |
Tooth Erosion Dentin-Bonding Agents Shear Strength |
description |
This in vitrostudy evaluated the immediate and 6 months microshear bond strength (µSBS) of different adhesive systems to sound and eroded dentin. Sixty bovine incisors were embedded in acrylic resin and ground to obtain flat buccal dentin surfaces. Specimens were randomly allocated into two groups: sound dentin (immersion in artificial saliva) and eroded dentin (erosive challenge following a pH cycling model comprising 4 ×/day Sprite Light® drink for 10 days). Then, specimens were reassigned according to the adhesive system: etch-and-rinse adhesive (Adper Single Bond), two-step self-etch system (Clearfil SE Bond), or one-step self-etch adhesive (Adper Easy One). Polyethylene tubes with an internal diameter of 0.76 mm were placed over pre-treated dentin and filled with resin composite (Z250). Half of the specimens were evaluated by the µSBS test after 24 h, and the other half 6 months later, after water storage at 37°C. Failure mode was evaluated using a stereomicroscope (400×). Data were analyzed by three-way repeated measures analysis of variance and Tukey’s post hoc tests (α = 0.05). After 6 months of water aging, marked reductions in µSBS values were observed, irrespective of the substrate. The µSBS values for eroded dentin were lower than those obtained for sound dentin. No difference in bonding effectiveness was observed among adhesive systems. For all groups, adhesive/mixed failure was observed. In conclusion, eroded dentin compromises the bonding quality of adhesive systems over time. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100284 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242015000100284 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1807-3107BOR-2015.vol29.0088 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
dc.source.none.fl_str_mv |
Brazilian Oral Research v.29 n.1 2015 reponame:Brazilian Oral Research instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO) instacron:SBPQO |
instname_str |
Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
instacron_str |
SBPQO |
institution |
SBPQO |
reponame_str |
Brazilian Oral Research |
collection |
Brazilian Oral Research |
repository.name.fl_str_mv |
Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
repository.mail.fl_str_mv |
pob@edu.usp.br||bor@sbpqo.org.br |
_version_ |
1750318324310343680 |