Bond strength of self-adhesive resin cements to dry and moist dentin

Detalhes bibliográficos
Autor(a) principal: Andre,Carolina Bosso
Data de Publicação: 2013
Outros Autores: Aguiar,Thaiane Rodrigues, Ayres,Ana Paula Almeida, Ambrosano,Glaucia Maria Bovi, Giannini,Marcelo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500389
Resumo: This study evaluated the effects of humidity conditions and evaluation times on the dentin bond strength (DBS) of two self-adhesive resin cements (RC). The RC used were: RelyX Unicem (3M ESPE) and Clearfil SA Cement (Kuraray Med.). One hundred and twenty coronal portions of bovine incisors (n = 10) were used. Buccal surfaces were abraded in order to expose a flat dentinal surface (180-grit SiC) and to standardize the smear layer formation (600-grit SiC). The humidity conditions tested were: dry (air-dried for 10 s), slightly moist (water application with disposable applicator on dried dentin and water excess removed with absorbent paper), and moist (same application without water removal). The RC were used according to the manufacturers' recommendations and were applied to prepolymerized resin discs (2 mm thick; Sinfony, 3M ESPE), which were subsequently bonded to the dentin surfaces. After 24 h, half of the teeth were prepared for the microtensile bond strength test, while the other half were stored in water for 6 months and tested in tension (0.5 mm/min) until failure. A 3-way analysis of variance and the Tukey test were performed (preset alpha of 0.05). No RC showed any reduction of DBS after 6 months, and no significant difference was observed between them. The moist dentin increased the bond strength of Clearfil SA Cement for both periods of time. Humidity conditions can change the DBS; however, the study's results were product-dependent.
id SBPQO-1_fe4a2d5f4fc22ef23e1a3030fad87007
oai_identifier_str oai:scielo:S1806-83242013000500389
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Bond strength of self-adhesive resin cements to dry and moist dentinDentinTensile StrengthResin CementsHumidityThis study evaluated the effects of humidity conditions and evaluation times on the dentin bond strength (DBS) of two self-adhesive resin cements (RC). The RC used were: RelyX Unicem (3M ESPE) and Clearfil SA Cement (Kuraray Med.). One hundred and twenty coronal portions of bovine incisors (n = 10) were used. Buccal surfaces were abraded in order to expose a flat dentinal surface (180-grit SiC) and to standardize the smear layer formation (600-grit SiC). The humidity conditions tested were: dry (air-dried for 10 s), slightly moist (water application with disposable applicator on dried dentin and water excess removed with absorbent paper), and moist (same application without water removal). The RC were used according to the manufacturers' recommendations and were applied to prepolymerized resin discs (2 mm thick; Sinfony, 3M ESPE), which were subsequently bonded to the dentin surfaces. After 24 h, half of the teeth were prepared for the microtensile bond strength test, while the other half were stored in water for 6 months and tested in tension (0.5 mm/min) until failure. A 3-way analysis of variance and the Tukey test were performed (preset alpha of 0.05). No RC showed any reduction of DBS after 6 months, and no significant difference was observed between them. The moist dentin increased the bond strength of Clearfil SA Cement for both periods of time. Humidity conditions can change the DBS; however, the study's results were product-dependent.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2013-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500389Brazilian Oral Research v.27 n.5 2013reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242013000500002info:eu-repo/semantics/openAccessAndre,Carolina BossoAguiar,Thaiane RodriguesAyres,Ana Paula AlmeidaAmbrosano,Glaucia Maria BoviGiannini,Marceloeng2013-10-08T00:00:00Zoai:scielo:S1806-83242013000500389Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2013-10-08T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Bond strength of self-adhesive resin cements to dry and moist dentin
title Bond strength of self-adhesive resin cements to dry and moist dentin
spellingShingle Bond strength of self-adhesive resin cements to dry and moist dentin
Andre,Carolina Bosso
Dentin
Tensile Strength
Resin Cements
Humidity
title_short Bond strength of self-adhesive resin cements to dry and moist dentin
title_full Bond strength of self-adhesive resin cements to dry and moist dentin
title_fullStr Bond strength of self-adhesive resin cements to dry and moist dentin
title_full_unstemmed Bond strength of self-adhesive resin cements to dry and moist dentin
title_sort Bond strength of self-adhesive resin cements to dry and moist dentin
author Andre,Carolina Bosso
author_facet Andre,Carolina Bosso
Aguiar,Thaiane Rodrigues
Ayres,Ana Paula Almeida
Ambrosano,Glaucia Maria Bovi
Giannini,Marcelo
author_role author
author2 Aguiar,Thaiane Rodrigues
Ayres,Ana Paula Almeida
Ambrosano,Glaucia Maria Bovi
Giannini,Marcelo
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Andre,Carolina Bosso
Aguiar,Thaiane Rodrigues
Ayres,Ana Paula Almeida
Ambrosano,Glaucia Maria Bovi
Giannini,Marcelo
dc.subject.por.fl_str_mv Dentin
Tensile Strength
Resin Cements
Humidity
topic Dentin
Tensile Strength
Resin Cements
Humidity
description This study evaluated the effects of humidity conditions and evaluation times on the dentin bond strength (DBS) of two self-adhesive resin cements (RC). The RC used were: RelyX Unicem (3M ESPE) and Clearfil SA Cement (Kuraray Med.). One hundred and twenty coronal portions of bovine incisors (n = 10) were used. Buccal surfaces were abraded in order to expose a flat dentinal surface (180-grit SiC) and to standardize the smear layer formation (600-grit SiC). The humidity conditions tested were: dry (air-dried for 10 s), slightly moist (water application with disposable applicator on dried dentin and water excess removed with absorbent paper), and moist (same application without water removal). The RC were used according to the manufacturers' recommendations and were applied to prepolymerized resin discs (2 mm thick; Sinfony, 3M ESPE), which were subsequently bonded to the dentin surfaces. After 24 h, half of the teeth were prepared for the microtensile bond strength test, while the other half were stored in water for 6 months and tested in tension (0.5 mm/min) until failure. A 3-way analysis of variance and the Tukey test were performed (preset alpha of 0.05). No RC showed any reduction of DBS after 6 months, and no significant difference was observed between them. The moist dentin increased the bond strength of Clearfil SA Cement for both periods of time. Humidity conditions can change the DBS; however, the study's results were product-dependent.
publishDate 2013
dc.date.none.fl_str_mv 2013-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500389
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500389
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242013000500002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.27 n.5 2013
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318323411714048