Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique

Detalhes bibliográficos
Autor(a) principal: Ortiz,Tatiana de Arruda
Data de Publicação: 2013
Outros Autores: Forti,Germano, Volpe,Márcia Souza, Carvalho,Carlos Roberto Ribeiro, Amato,Marcelo Brito Passos, Tucci,Mauro Roberto
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Brasileiro de Pneumologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132013000200205
Resumo: OBJECTIVE: To evaluate, in a lung model simulating a mechanically ventilated patient, the efficiency and safety of the manual hyperinflation (MH) maneuver as a means of removing pulmonary secretions. METHODS: Eight respiratory therapists (RTs) were asked to use a self-inflating manual resuscitator on a lung model to perform MH as if to remove secretions, under two conditions: as routinely applied during their clinical practice; and after receiving verbal instructions based on expert recommendations. In both conditions, three clinical scenarios were simulated: normal lung function, restrictive lung disease, and obstructive lung disease. RESULTS: Before instruction, it was common for an RT to compress the resuscitator bag two times, in rapid succession. Proximal pressure (Pprox) was higher before instruction than after. However, alveolar pressure (Palv) never exceeded 42.5 cmH2O (median, 16.1; interquartile range [IQR], 11.7-24.5), despite Pprox values as high as 96.6 cmH2O (median, 36.7; IQR, 22.9-49.4). The tidal volume (VT) generated was relatively low (median, 640 mL; IQR, 505-735), and peak inspiratory flow (PIF) often exceeded peak expiratory flow (PEF), the median values being 1.37 L/s (IQR, 0.99-1.90) and 1.01 L/s (IQR, 0.55-1.28), respectively. A PIF/PEF ratio < 0.9 (which theoretically favors mucus migration toward the central airways) was achieved in only 16.7% of the maneuvers. CONCLUSIONS: Under the conditions tested, MH produced safe Palv levels despite high Pprox. However, the MH maneuver was often performed in a way that did not favor secretion removal (PIF exceeding PEF), even after instruction. The unfavorable PIF/PEF ratio was attributable to overly rapid inflations and low VT.
id SBPT-1_6d0f783b2696f830dab329bf0cac7e11
oai_identifier_str oai:scielo:S1806-37132013000200205
network_acronym_str SBPT-1
network_name_str Jornal Brasileiro de Pneumologia (Online)
repository_id_str
spelling Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance techniquePhysical therapy modalitiesRespiratory therapyRespiratory mechanicsPositive-pressure respiration OBJECTIVE: To evaluate, in a lung model simulating a mechanically ventilated patient, the efficiency and safety of the manual hyperinflation (MH) maneuver as a means of removing pulmonary secretions. METHODS: Eight respiratory therapists (RTs) were asked to use a self-inflating manual resuscitator on a lung model to perform MH as if to remove secretions, under two conditions: as routinely applied during their clinical practice; and after receiving verbal instructions based on expert recommendations. In both conditions, three clinical scenarios were simulated: normal lung function, restrictive lung disease, and obstructive lung disease. RESULTS: Before instruction, it was common for an RT to compress the resuscitator bag two times, in rapid succession. Proximal pressure (Pprox) was higher before instruction than after. However, alveolar pressure (Palv) never exceeded 42.5 cmH2O (median, 16.1; interquartile range [IQR], 11.7-24.5), despite Pprox values as high as 96.6 cmH2O (median, 36.7; IQR, 22.9-49.4). The tidal volume (VT) generated was relatively low (median, 640 mL; IQR, 505-735), and peak inspiratory flow (PIF) often exceeded peak expiratory flow (PEF), the median values being 1.37 L/s (IQR, 0.99-1.90) and 1.01 L/s (IQR, 0.55-1.28), respectively. A PIF/PEF ratio < 0.9 (which theoretically favors mucus migration toward the central airways) was achieved in only 16.7% of the maneuvers. CONCLUSIONS: Under the conditions tested, MH produced safe Palv levels despite high Pprox. However, the MH maneuver was often performed in a way that did not favor secretion removal (PIF exceeding PEF), even after instruction. The unfavorable PIF/PEF ratio was attributable to overly rapid inflations and low VT.Sociedade Brasileira de Pneumologia e Tisiologia2013-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132013000200205Jornal Brasileiro de Pneumologia v.39 n.2 2013reponame:Jornal Brasileiro de Pneumologia (Online)instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)instacron:SBPT10.1590/S1806-37132013000200012info:eu-repo/semantics/openAccessOrtiz,Tatiana de ArrudaForti,GermanoVolpe,Márcia SouzaCarvalho,Carlos Roberto RibeiroAmato,Marcelo Brito PassosTucci,Mauro Robertoeng2016-08-18T00:00:00Zoai:scielo:S1806-37132013000200205Revistahttp://www.jornaldepneumologia.com.br/default.aspONGhttps://old.scielo.br/oai/scielo-oai.php||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br1806-37561806-3713opendoar:2016-08-18T00:00Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)false
dc.title.none.fl_str_mv Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
title Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
spellingShingle Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
Ortiz,Tatiana de Arruda
Physical therapy modalities
Respiratory therapy
Respiratory mechanics
Positive-pressure respiration
title_short Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
title_full Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
title_fullStr Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
title_full_unstemmed Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
title_sort Experimental study on the efficiency and safety of the manual hyperinflation maneuver as a secretion clearance technique
author Ortiz,Tatiana de Arruda
author_facet Ortiz,Tatiana de Arruda
Forti,Germano
Volpe,Márcia Souza
Carvalho,Carlos Roberto Ribeiro
Amato,Marcelo Brito Passos
Tucci,Mauro Roberto
author_role author
author2 Forti,Germano
Volpe,Márcia Souza
Carvalho,Carlos Roberto Ribeiro
Amato,Marcelo Brito Passos
Tucci,Mauro Roberto
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Ortiz,Tatiana de Arruda
Forti,Germano
Volpe,Márcia Souza
Carvalho,Carlos Roberto Ribeiro
Amato,Marcelo Brito Passos
Tucci,Mauro Roberto
dc.subject.por.fl_str_mv Physical therapy modalities
Respiratory therapy
Respiratory mechanics
Positive-pressure respiration
topic Physical therapy modalities
Respiratory therapy
Respiratory mechanics
Positive-pressure respiration
description OBJECTIVE: To evaluate, in a lung model simulating a mechanically ventilated patient, the efficiency and safety of the manual hyperinflation (MH) maneuver as a means of removing pulmonary secretions. METHODS: Eight respiratory therapists (RTs) were asked to use a self-inflating manual resuscitator on a lung model to perform MH as if to remove secretions, under two conditions: as routinely applied during their clinical practice; and after receiving verbal instructions based on expert recommendations. In both conditions, three clinical scenarios were simulated: normal lung function, restrictive lung disease, and obstructive lung disease. RESULTS: Before instruction, it was common for an RT to compress the resuscitator bag two times, in rapid succession. Proximal pressure (Pprox) was higher before instruction than after. However, alveolar pressure (Palv) never exceeded 42.5 cmH2O (median, 16.1; interquartile range [IQR], 11.7-24.5), despite Pprox values as high as 96.6 cmH2O (median, 36.7; IQR, 22.9-49.4). The tidal volume (VT) generated was relatively low (median, 640 mL; IQR, 505-735), and peak inspiratory flow (PIF) often exceeded peak expiratory flow (PEF), the median values being 1.37 L/s (IQR, 0.99-1.90) and 1.01 L/s (IQR, 0.55-1.28), respectively. A PIF/PEF ratio < 0.9 (which theoretically favors mucus migration toward the central airways) was achieved in only 16.7% of the maneuvers. CONCLUSIONS: Under the conditions tested, MH produced safe Palv levels despite high Pprox. However, the MH maneuver was often performed in a way that did not favor secretion removal (PIF exceeding PEF), even after instruction. The unfavorable PIF/PEF ratio was attributable to overly rapid inflations and low VT.
publishDate 2013
dc.date.none.fl_str_mv 2013-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132013000200205
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132013000200205
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-37132013000200012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
dc.source.none.fl_str_mv Jornal Brasileiro de Pneumologia v.39 n.2 2013
reponame:Jornal Brasileiro de Pneumologia (Online)
instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron:SBPT
instname_str Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron_str SBPT
institution SBPT
reponame_str Jornal Brasileiro de Pneumologia (Online)
collection Jornal Brasileiro de Pneumologia (Online)
repository.name.fl_str_mv Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
repository.mail.fl_str_mv ||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br
_version_ 1750318345494724608