Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD

Detalhes bibliográficos
Autor(a) principal: Fonseca,Fernanda Rodrigues
Data de Publicação: 2018
Outros Autores: Karloh,Manuela, Araujo,Cintia Laura Pereira de, Reis,Cardine Martins dos, Mayer,Anamaria Fleig
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Jornal Brasileiro de Pneumologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400315
Resumo: ABSTRACT Objective: To investigate the validity of an eight-contact electrode bioelectrical impedance analysis (BIA) system within a household scale for assessing whole body composition in COPD patients. Methods: Seventeen patients with COPD (mean age = 67 ± 8 years; mean FEV1 = 38.6 ± 16.1% of predicted; and mean body mass index = 24.7 ± 5.4 kg/m2) underwent dual-energy X-ray absorptiometry (DEXA) and an eight-contact electrode BIA system for body composition assessment. Results: There was a strong inter-method correlation for fat mass (r = 0.95), fat-free mass (r = 0.93), and lean mass (r = 0.93), but the correlation was moderate for bone mineral content (r = 0.73; p < 0.01 for all). In the agreement analysis, the values between DEXA and the BIA system differed by only 0.15 kg (−6.39 to 6.70 kg), 0.26 kg (−5.96 to 6.49 kg), −0.13 kg (−0.76 to 0.50 kg), and −0.55 kg (−6.71 to 5.61 kg) for fat-free mass, lean mass, bone mineral content, and fat mass, respectively. Conclusions: The eight-contact electrode BIA system showed to be a valid tool in the assessment of whole body composition in our sample of patients with COPD.
id SBPT-1_89e154dac8ce94e939b33a1defe2f230
oai_identifier_str oai:scielo:S1806-37132018000400315
network_acronym_str SBPT-1
network_name_str Jornal Brasileiro de Pneumologia (Online)
repository_id_str
spelling Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPDPulmonary disease, chronic obstructiveBody compositionElectric impedanceABSTRACT Objective: To investigate the validity of an eight-contact electrode bioelectrical impedance analysis (BIA) system within a household scale for assessing whole body composition in COPD patients. Methods: Seventeen patients with COPD (mean age = 67 ± 8 years; mean FEV1 = 38.6 ± 16.1% of predicted; and mean body mass index = 24.7 ± 5.4 kg/m2) underwent dual-energy X-ray absorptiometry (DEXA) and an eight-contact electrode BIA system for body composition assessment. Results: There was a strong inter-method correlation for fat mass (r = 0.95), fat-free mass (r = 0.93), and lean mass (r = 0.93), but the correlation was moderate for bone mineral content (r = 0.73; p < 0.01 for all). In the agreement analysis, the values between DEXA and the BIA system differed by only 0.15 kg (−6.39 to 6.70 kg), 0.26 kg (−5.96 to 6.49 kg), −0.13 kg (−0.76 to 0.50 kg), and −0.55 kg (−6.71 to 5.61 kg) for fat-free mass, lean mass, bone mineral content, and fat mass, respectively. Conclusions: The eight-contact electrode BIA system showed to be a valid tool in the assessment of whole body composition in our sample of patients with COPD.Sociedade Brasileira de Pneumologia e Tisiologia2018-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400315Jornal Brasileiro de Pneumologia v.44 n.4 2018reponame:Jornal Brasileiro de Pneumologia (Online)instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)instacron:SBPT10.1590/s1806-37562017000000121info:eu-repo/semantics/openAccessFonseca,Fernanda RodriguesKarloh,ManuelaAraujo,Cintia Laura Pereira deReis,Cardine Martins dosMayer,Anamaria Fleigeng2018-10-08T00:00:00Zoai:scielo:S1806-37132018000400315Revistahttp://www.jornaldepneumologia.com.br/default.aspONGhttps://old.scielo.br/oai/scielo-oai.php||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br1806-37561806-3713opendoar:2018-10-08T00:00Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)false
dc.title.none.fl_str_mv Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
title Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
spellingShingle Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
Fonseca,Fernanda Rodrigues
Pulmonary disease, chronic obstructive
Body composition
Electric impedance
title_short Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
title_full Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
title_fullStr Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
title_full_unstemmed Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
title_sort Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD
author Fonseca,Fernanda Rodrigues
author_facet Fonseca,Fernanda Rodrigues
Karloh,Manuela
Araujo,Cintia Laura Pereira de
Reis,Cardine Martins dos
Mayer,Anamaria Fleig
author_role author
author2 Karloh,Manuela
Araujo,Cintia Laura Pereira de
Reis,Cardine Martins dos
Mayer,Anamaria Fleig
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Fonseca,Fernanda Rodrigues
Karloh,Manuela
Araujo,Cintia Laura Pereira de
Reis,Cardine Martins dos
Mayer,Anamaria Fleig
dc.subject.por.fl_str_mv Pulmonary disease, chronic obstructive
Body composition
Electric impedance
topic Pulmonary disease, chronic obstructive
Body composition
Electric impedance
description ABSTRACT Objective: To investigate the validity of an eight-contact electrode bioelectrical impedance analysis (BIA) system within a household scale for assessing whole body composition in COPD patients. Methods: Seventeen patients with COPD (mean age = 67 ± 8 years; mean FEV1 = 38.6 ± 16.1% of predicted; and mean body mass index = 24.7 ± 5.4 kg/m2) underwent dual-energy X-ray absorptiometry (DEXA) and an eight-contact electrode BIA system for body composition assessment. Results: There was a strong inter-method correlation for fat mass (r = 0.95), fat-free mass (r = 0.93), and lean mass (r = 0.93), but the correlation was moderate for bone mineral content (r = 0.73; p < 0.01 for all). In the agreement analysis, the values between DEXA and the BIA system differed by only 0.15 kg (−6.39 to 6.70 kg), 0.26 kg (−5.96 to 6.49 kg), −0.13 kg (−0.76 to 0.50 kg), and −0.55 kg (−6.71 to 5.61 kg) for fat-free mass, lean mass, bone mineral content, and fat mass, respectively. Conclusions: The eight-contact electrode BIA system showed to be a valid tool in the assessment of whole body composition in our sample of patients with COPD.
publishDate 2018
dc.date.none.fl_str_mv 2018-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400315
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400315
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1806-37562017000000121
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
publisher.none.fl_str_mv Sociedade Brasileira de Pneumologia e Tisiologia
dc.source.none.fl_str_mv Jornal Brasileiro de Pneumologia v.44 n.4 2018
reponame:Jornal Brasileiro de Pneumologia (Online)
instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron:SBPT
instname_str Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
instacron_str SBPT
institution SBPT
reponame_str Jornal Brasileiro de Pneumologia (Online)
collection Jornal Brasileiro de Pneumologia (Online)
repository.name.fl_str_mv Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)
repository.mail.fl_str_mv ||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br
_version_ 1750318347247943680