The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal Brasileiro de Pneumologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132016000300203 |
Resumo: | ABSTRACT Objective: Ventilator-associated pneumonia (VAP) is the leading type of hospital-acquired infection in ICU patients. The diagnosis of VAP is challenging, mostly due to limitations of the diagnostic methods available. The aim of this study was to determine whether antibody-coated bacteria (ACB) evaluation can improve the specificity of endotracheal aspirate (EA) culture in VAP diagnosis. Methods: We conducted a diagnostic case-control study, enrolling 45 patients undergoing mechanical ventilation. Samples of EA were obtained from patients with and without VAP (cases and controls, respectively), and we assessed the number of bacteria coated with FITC-conjugated monoclonal antibodies (IgA, IgM, or IgG) or an FITC-conjugated polyvalent antibody. Using immunofluorescence microscopy, we determined the proportion of ACB among a fixed number of 80 bacteria. Results: The median proportions of ACB were significantly higher among the cases (n = 22) than among the controls (n = 23)-IgA (60.6% vs. 22.5%), IgM (42.5% vs. 12.5%), IgG (50.6% vs. 17.5%), and polyvalent (75.6% vs. 33.8%)-p < 0.001 for all. The accuracy of the best cut-off points for VAP diagnosis regarding monoclonal and polyvalent ACBs was greater than 95.0% and 93.3%, respectively. Conclusions: The numbers of ACB in EA samples were higher among cases than among controls. Our findings indicate that evaluating ACB in EA is a promising tool to improve the specificity of VAP diagnosis. The technique could be cost-effective and therefore useful in low-resource settings, with the advantages of minimizing false-positive results and avoiding overtreatment. |
id |
SBPT-1_92b55a6d45b918c1a50230f00976127d |
---|---|
oai_identifier_str |
oai:scielo:S1806-37132016000300203 |
network_acronym_str |
SBPT-1 |
network_name_str |
Jornal Brasileiro de Pneumologia (Online) |
repository_id_str |
|
spelling |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control studyPneumonia, ventilator-associated/diagnosisImmunohistochemistryFluorescent antibody techniqueAntibodies, bacterial/analysisTrachea/microbiologyIntensive care unitsABSTRACT Objective: Ventilator-associated pneumonia (VAP) is the leading type of hospital-acquired infection in ICU patients. The diagnosis of VAP is challenging, mostly due to limitations of the diagnostic methods available. The aim of this study was to determine whether antibody-coated bacteria (ACB) evaluation can improve the specificity of endotracheal aspirate (EA) culture in VAP diagnosis. Methods: We conducted a diagnostic case-control study, enrolling 45 patients undergoing mechanical ventilation. Samples of EA were obtained from patients with and without VAP (cases and controls, respectively), and we assessed the number of bacteria coated with FITC-conjugated monoclonal antibodies (IgA, IgM, or IgG) or an FITC-conjugated polyvalent antibody. Using immunofluorescence microscopy, we determined the proportion of ACB among a fixed number of 80 bacteria. Results: The median proportions of ACB were significantly higher among the cases (n = 22) than among the controls (n = 23)-IgA (60.6% vs. 22.5%), IgM (42.5% vs. 12.5%), IgG (50.6% vs. 17.5%), and polyvalent (75.6% vs. 33.8%)-p < 0.001 for all. The accuracy of the best cut-off points for VAP diagnosis regarding monoclonal and polyvalent ACBs was greater than 95.0% and 93.3%, respectively. Conclusions: The numbers of ACB in EA samples were higher among cases than among controls. Our findings indicate that evaluating ACB in EA is a promising tool to improve the specificity of VAP diagnosis. The technique could be cost-effective and therefore useful in low-resource settings, with the advantages of minimizing false-positive results and avoiding overtreatment.Sociedade Brasileira de Pneumologia e Tisiologia2016-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132016000300203Jornal Brasileiro de Pneumologia v.42 n.3 2016reponame:Jornal Brasileiro de Pneumologia (Online)instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)instacron:SBPT10.1590/S1806-37562015000000244info:eu-repo/semantics/openAccessRanzani,Otavio TavaresForte,Daniel NevesForte,Antonio CarlosMimica,IgorForte,Wilma Carvalho Neveseng2016-06-29T00:00:00Zoai:scielo:S1806-37132016000300203Revistahttp://www.jornaldepneumologia.com.br/default.aspONGhttps://old.scielo.br/oai/scielo-oai.php||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br1806-37561806-3713opendoar:2016-06-29T00:00Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)false |
dc.title.none.fl_str_mv |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study |
title |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study |
spellingShingle |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study Ranzani,Otavio Tavares Pneumonia, ventilator-associated/diagnosis Immunohistochemistry Fluorescent antibody technique Antibodies, bacterial/analysis Trachea/microbiology Intensive care units |
title_short |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study |
title_full |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study |
title_fullStr |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study |
title_full_unstemmed |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study |
title_sort |
The value of antibody-coated bacteria in tracheal aspirates for the diagnosis of ventilator-associated pneumonia: a case-control study |
author |
Ranzani,Otavio Tavares |
author_facet |
Ranzani,Otavio Tavares Forte,Daniel Neves Forte,Antonio Carlos Mimica,Igor Forte,Wilma Carvalho Neves |
author_role |
author |
author2 |
Forte,Daniel Neves Forte,Antonio Carlos Mimica,Igor Forte,Wilma Carvalho Neves |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Ranzani,Otavio Tavares Forte,Daniel Neves Forte,Antonio Carlos Mimica,Igor Forte,Wilma Carvalho Neves |
dc.subject.por.fl_str_mv |
Pneumonia, ventilator-associated/diagnosis Immunohistochemistry Fluorescent antibody technique Antibodies, bacterial/analysis Trachea/microbiology Intensive care units |
topic |
Pneumonia, ventilator-associated/diagnosis Immunohistochemistry Fluorescent antibody technique Antibodies, bacterial/analysis Trachea/microbiology Intensive care units |
description |
ABSTRACT Objective: Ventilator-associated pneumonia (VAP) is the leading type of hospital-acquired infection in ICU patients. The diagnosis of VAP is challenging, mostly due to limitations of the diagnostic methods available. The aim of this study was to determine whether antibody-coated bacteria (ACB) evaluation can improve the specificity of endotracheal aspirate (EA) culture in VAP diagnosis. Methods: We conducted a diagnostic case-control study, enrolling 45 patients undergoing mechanical ventilation. Samples of EA were obtained from patients with and without VAP (cases and controls, respectively), and we assessed the number of bacteria coated with FITC-conjugated monoclonal antibodies (IgA, IgM, or IgG) or an FITC-conjugated polyvalent antibody. Using immunofluorescence microscopy, we determined the proportion of ACB among a fixed number of 80 bacteria. Results: The median proportions of ACB were significantly higher among the cases (n = 22) than among the controls (n = 23)-IgA (60.6% vs. 22.5%), IgM (42.5% vs. 12.5%), IgG (50.6% vs. 17.5%), and polyvalent (75.6% vs. 33.8%)-p < 0.001 for all. The accuracy of the best cut-off points for VAP diagnosis regarding monoclonal and polyvalent ACBs was greater than 95.0% and 93.3%, respectively. Conclusions: The numbers of ACB in EA samples were higher among cases than among controls. Our findings indicate that evaluating ACB in EA is a promising tool to improve the specificity of VAP diagnosis. The technique could be cost-effective and therefore useful in low-resource settings, with the advantages of minimizing false-positive results and avoiding overtreatment. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132016000300203 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132016000300203 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1806-37562015000000244 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pneumologia e Tisiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pneumologia e Tisiologia |
dc.source.none.fl_str_mv |
Jornal Brasileiro de Pneumologia v.42 n.3 2016 reponame:Jornal Brasileiro de Pneumologia (Online) instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) instacron:SBPT |
instname_str |
Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) |
instacron_str |
SBPT |
institution |
SBPT |
reponame_str |
Jornal Brasileiro de Pneumologia (Online) |
collection |
Jornal Brasileiro de Pneumologia (Online) |
repository.name.fl_str_mv |
Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) |
repository.mail.fl_str_mv |
||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br |
_version_ |
1750318346429005824 |