CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Jornal Brasileiro de Pneumologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400307 |
Resumo: | ABSTRACT Objective: To evaluate the diagnostic accuracy of CT-guided percutaneous core needle biopsy (CT-CNB) of pulmonary nodules ≤ 2 cm, as well as to identify factors influencing the accuracy of the procedure and its morbidity. Methods: This was a retrospective, single-center study of 170 consecutive patients undergoing CT-CNB of small pulmonary nodules (of ≤ 2 cm) between January of 2010 and August of 2015. Results: A total of 156 CT-CNBs yielded a definitive diagnosis, the overall diagnostic accuracy being 92.3%. Larger lesions were associated with a higher overall accuracy (OR = 1.30; p = 0.007). Parenchymal hemorrhage occurring during the procedure led to lower accuracy rates (OR = 0.13; p = 0.022). Pneumothorax was the most common complication. A pleura-to-lesion distance > 3 cm was identified as a risk factor for pneumothorax (OR = 16.94), whereas performing a blood patch after biopsy was a protective factor for pneumothorax (OR = 0.18). Conclusions: Small nodules (of < 2 cm) represent a technical challenge for diagnosis. CT-CNB is an excellent diagnostic tool, its accuracy being high. |
id |
SBPT-1_97d254ca94ec996d5105b254e9600849 |
---|---|
oai_identifier_str |
oai:scielo:S1806-37132018000400307 |
network_acronym_str |
SBPT-1 |
network_name_str |
Jornal Brasileiro de Pneumologia (Online) |
repository_id_str |
|
spelling |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracyImage-guided biopsyNeoplasmsLungABSTRACT Objective: To evaluate the diagnostic accuracy of CT-guided percutaneous core needle biopsy (CT-CNB) of pulmonary nodules ≤ 2 cm, as well as to identify factors influencing the accuracy of the procedure and its morbidity. Methods: This was a retrospective, single-center study of 170 consecutive patients undergoing CT-CNB of small pulmonary nodules (of ≤ 2 cm) between January of 2010 and August of 2015. Results: A total of 156 CT-CNBs yielded a definitive diagnosis, the overall diagnostic accuracy being 92.3%. Larger lesions were associated with a higher overall accuracy (OR = 1.30; p = 0.007). Parenchymal hemorrhage occurring during the procedure led to lower accuracy rates (OR = 0.13; p = 0.022). Pneumothorax was the most common complication. A pleura-to-lesion distance > 3 cm was identified as a risk factor for pneumothorax (OR = 16.94), whereas performing a blood patch after biopsy was a protective factor for pneumothorax (OR = 0.18). Conclusions: Small nodules (of < 2 cm) represent a technical challenge for diagnosis. CT-CNB is an excellent diagnostic tool, its accuracy being high.Sociedade Brasileira de Pneumologia e Tisiologia2018-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400307Jornal Brasileiro de Pneumologia v.44 n.4 2018reponame:Jornal Brasileiro de Pneumologia (Online)instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)instacron:SBPT10.1590/s1806-37562017000000259info:eu-repo/semantics/openAccessAndrade,Juliano Ribeiro deRocha,Rafael DahmerFalsarella,Priscila MinaRahal Junior,AntonioSantos,Ricardo Sales dosFranceschini,Juliana PereiraFernando,Hiran ChrishanthaGarcia,Rodrigo Gobboeng2018-10-08T00:00:00Zoai:scielo:S1806-37132018000400307Revistahttp://www.jornaldepneumologia.com.br/default.aspONGhttps://old.scielo.br/oai/scielo-oai.php||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br1806-37561806-3713opendoar:2018-10-08T00:00Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT)false |
dc.title.none.fl_str_mv |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy |
title |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy |
spellingShingle |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy Andrade,Juliano Ribeiro de Image-guided biopsy Neoplasms Lung |
title_short |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy |
title_full |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy |
title_fullStr |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy |
title_full_unstemmed |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy |
title_sort |
CT-guided percutaneous core needle biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors influencing accuracy |
author |
Andrade,Juliano Ribeiro de |
author_facet |
Andrade,Juliano Ribeiro de Rocha,Rafael Dahmer Falsarella,Priscila Mina Rahal Junior,Antonio Santos,Ricardo Sales dos Franceschini,Juliana Pereira Fernando,Hiran Chrishantha Garcia,Rodrigo Gobbo |
author_role |
author |
author2 |
Rocha,Rafael Dahmer Falsarella,Priscila Mina Rahal Junior,Antonio Santos,Ricardo Sales dos Franceschini,Juliana Pereira Fernando,Hiran Chrishantha Garcia,Rodrigo Gobbo |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Andrade,Juliano Ribeiro de Rocha,Rafael Dahmer Falsarella,Priscila Mina Rahal Junior,Antonio Santos,Ricardo Sales dos Franceschini,Juliana Pereira Fernando,Hiran Chrishantha Garcia,Rodrigo Gobbo |
dc.subject.por.fl_str_mv |
Image-guided biopsy Neoplasms Lung |
topic |
Image-guided biopsy Neoplasms Lung |
description |
ABSTRACT Objective: To evaluate the diagnostic accuracy of CT-guided percutaneous core needle biopsy (CT-CNB) of pulmonary nodules ≤ 2 cm, as well as to identify factors influencing the accuracy of the procedure and its morbidity. Methods: This was a retrospective, single-center study of 170 consecutive patients undergoing CT-CNB of small pulmonary nodules (of ≤ 2 cm) between January of 2010 and August of 2015. Results: A total of 156 CT-CNBs yielded a definitive diagnosis, the overall diagnostic accuracy being 92.3%. Larger lesions were associated with a higher overall accuracy (OR = 1.30; p = 0.007). Parenchymal hemorrhage occurring during the procedure led to lower accuracy rates (OR = 0.13; p = 0.022). Pneumothorax was the most common complication. A pleura-to-lesion distance > 3 cm was identified as a risk factor for pneumothorax (OR = 16.94), whereas performing a blood patch after biopsy was a protective factor for pneumothorax (OR = 0.18). Conclusions: Small nodules (of < 2 cm) represent a technical challenge for diagnosis. CT-CNB is an excellent diagnostic tool, its accuracy being high. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400307 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-37132018000400307 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s1806-37562017000000259 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pneumologia e Tisiologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pneumologia e Tisiologia |
dc.source.none.fl_str_mv |
Jornal Brasileiro de Pneumologia v.44 n.4 2018 reponame:Jornal Brasileiro de Pneumologia (Online) instname:Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) instacron:SBPT |
instname_str |
Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) |
instacron_str |
SBPT |
institution |
SBPT |
reponame_str |
Jornal Brasileiro de Pneumologia (Online) |
collection |
Jornal Brasileiro de Pneumologia (Online) |
repository.name.fl_str_mv |
Jornal Brasileiro de Pneumologia (Online) - Sociedade Brasileira de Pneumologia e Tisiologia (SBPT) |
repository.mail.fl_str_mv |
||jbp@jbp.org.br|| jpneumo@jornaldepneumologia.com.br |
_version_ |
1750318347246895104 |