Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532021000701456 |
Resumo: | This paper reports the use of polished silver solid amalgam electrode (p-AgSAE) allied to square wave voltammetry (SWV) in the development of a simple, sensitive, fast and green electroanalytical methodology for the trifluralin herbicide determination in fresh food samples. The experimental (supporting electrolyte and potential and time accumulation) and voltammetric (pulse frequency, pulse amplitude and scan increment potential) parameters were previously optimized, which were employed in the construction of analytical curves. Therefore, these curves have enabled the calculation of analytical parameters (linearity range, equation of the analytical curves, coefficients of determination, limits of detection and quantification, recovery efficiency, and relative standard deviations for intraday and interday experiments) and they indicated that the use of the p-AgSAE is suitable for determining any contamination by trifluralin. So, the proposed methodology had to minimize the toxic residues due to the use of liquid mercury or the adsorbed products from the redox reaction that promotes passivation in the other solid surfaces. Furthermore, the optimized methodology was used to trifluralin determination in eggplant, carrot, tomato, grape juice and orange juice, and the results indicated that the proposed methodology presented high robustness, stability and sensitivity, good reproducibility, and hence it is applicable for complex samples. |
id |
SBQ-2_0cb7b83ed7c429d5fa07d2886b1f626f |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532021000701456 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samplestrifluralinelectrochemical behaviorfresh food samplespolished silver solid amalgam electrodesquare wave voltammetryThis paper reports the use of polished silver solid amalgam electrode (p-AgSAE) allied to square wave voltammetry (SWV) in the development of a simple, sensitive, fast and green electroanalytical methodology for the trifluralin herbicide determination in fresh food samples. The experimental (supporting electrolyte and potential and time accumulation) and voltammetric (pulse frequency, pulse amplitude and scan increment potential) parameters were previously optimized, which were employed in the construction of analytical curves. Therefore, these curves have enabled the calculation of analytical parameters (linearity range, equation of the analytical curves, coefficients of determination, limits of detection and quantification, recovery efficiency, and relative standard deviations for intraday and interday experiments) and they indicated that the use of the p-AgSAE is suitable for determining any contamination by trifluralin. So, the proposed methodology had to minimize the toxic residues due to the use of liquid mercury or the adsorbed products from the redox reaction that promotes passivation in the other solid surfaces. Furthermore, the optimized methodology was used to trifluralin determination in eggplant, carrot, tomato, grape juice and orange juice, and the results indicated that the proposed methodology presented high robustness, stability and sensitivity, good reproducibility, and hence it is applicable for complex samples.Sociedade Brasileira de Química2021-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532021000701456Journal of the Brazilian Chemical Society v.32 n.7 2021reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20210044info:eu-repo/semantics/openAccessGonçalves Filho,DanielleSouza,Djenaine deeng2021-06-30T00:00:00Zoai:scielo:S0103-50532021000701456Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2021-06-30T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples |
title |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples |
spellingShingle |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples Gonçalves Filho,Danielle trifluralin electrochemical behavior fresh food samples polished silver solid amalgam electrode square wave voltammetry |
title_short |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples |
title_full |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples |
title_fullStr |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples |
title_full_unstemmed |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples |
title_sort |
Electrochemical Determination of Trifluralin Herbicide Using Silver Solid Amalgam Electrode: Application in Fresh Food Samples |
author |
Gonçalves Filho,Danielle |
author_facet |
Gonçalves Filho,Danielle Souza,Djenaine de |
author_role |
author |
author2 |
Souza,Djenaine de |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Gonçalves Filho,Danielle Souza,Djenaine de |
dc.subject.por.fl_str_mv |
trifluralin electrochemical behavior fresh food samples polished silver solid amalgam electrode square wave voltammetry |
topic |
trifluralin electrochemical behavior fresh food samples polished silver solid amalgam electrode square wave voltammetry |
description |
This paper reports the use of polished silver solid amalgam electrode (p-AgSAE) allied to square wave voltammetry (SWV) in the development of a simple, sensitive, fast and green electroanalytical methodology for the trifluralin herbicide determination in fresh food samples. The experimental (supporting electrolyte and potential and time accumulation) and voltammetric (pulse frequency, pulse amplitude and scan increment potential) parameters were previously optimized, which were employed in the construction of analytical curves. Therefore, these curves have enabled the calculation of analytical parameters (linearity range, equation of the analytical curves, coefficients of determination, limits of detection and quantification, recovery efficiency, and relative standard deviations for intraday and interday experiments) and they indicated that the use of the p-AgSAE is suitable for determining any contamination by trifluralin. So, the proposed methodology had to minimize the toxic residues due to the use of liquid mercury or the adsorbed products from the redox reaction that promotes passivation in the other solid surfaces. Furthermore, the optimized methodology was used to trifluralin determination in eggplant, carrot, tomato, grape juice and orange juice, and the results indicated that the proposed methodology presented high robustness, stability and sensitivity, good reproducibility, and hence it is applicable for complex samples. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-07-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532021000701456 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532021000701456 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.21577/0103-5053.20210044 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.32 n.7 2021 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318184371585024 |