Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID

Detalhes bibliográficos
Autor(a) principal: Jamil,Lazgin A.
Data de Publicação: 2020
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020000300580
Resumo: A continuous sample drop flow microextraction (CSDF-ME) technique was modified for the pretreatment of plasma samples in the determination of methadone and codeine. The limit of detection and linear range for methadone were 15.0 µg L-1 and 0.1-10.0 mg L-1, respectively. The detection limit and linear range for codeine were 25.0 µg L-1 and 0.2-15.0 mg L-1, respectively. The extraction recoveries were 41.6-52.1%, and the enrichment factors ranged from 65 to 80 for codeine and methadone, respectively. Intra- and interday precisions of the technique were calculated for codeine and methadone concentrations of 0.4 mg L-1 and were 4.2-7.6% and 2.5-5.1%, respectively. Also, the accuracy (error%) of method was in the range -10 to +7.5%. The applicability of the CSDF-ME-gas chromatography-flame ionization detector (GC-FID) technique was illustrated by the determination of the mentioned drugs in human plasma. The attained relative recoveries of methadone and codeine in the 90.0-107.5% range demonstrated the excellent capability of the optimized technique for the microextraction of the mentioned drugs from plasma. The CSDF-ME-GC-FID is a rapid, repeatable and very simple technique that requires a low sample amount.
id SBQ-2_214dd52023dce8c5c04d4903a5cc6258
oai_identifier_str oai:scielo:S0103-50532020000300580
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FIDmethadonecodeinecontinuous sample drop flow microextractiongas chromatographyA continuous sample drop flow microextraction (CSDF-ME) technique was modified for the pretreatment of plasma samples in the determination of methadone and codeine. The limit of detection and linear range for methadone were 15.0 µg L-1 and 0.1-10.0 mg L-1, respectively. The detection limit and linear range for codeine were 25.0 µg L-1 and 0.2-15.0 mg L-1, respectively. The extraction recoveries were 41.6-52.1%, and the enrichment factors ranged from 65 to 80 for codeine and methadone, respectively. Intra- and interday precisions of the technique were calculated for codeine and methadone concentrations of 0.4 mg L-1 and were 4.2-7.6% and 2.5-5.1%, respectively. Also, the accuracy (error%) of method was in the range -10 to +7.5%. The applicability of the CSDF-ME-gas chromatography-flame ionization detector (GC-FID) technique was illustrated by the determination of the mentioned drugs in human plasma. The attained relative recoveries of methadone and codeine in the 90.0-107.5% range demonstrated the excellent capability of the optimized technique for the microextraction of the mentioned drugs from plasma. The CSDF-ME-GC-FID is a rapid, repeatable and very simple technique that requires a low sample amount.Sociedade Brasileira de Química2020-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020000300580Journal of the Brazilian Chemical Society v.31 n.3 2020reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20190220info:eu-repo/semantics/openAccessJamil,Lazgin A.eng2020-02-27T00:00:00Zoai:scielo:S0103-50532020000300580Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2020-02-27T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
title Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
spellingShingle Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
Jamil,Lazgin A.
methadone
codeine
continuous sample drop flow microextraction
gas chromatography
title_short Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
title_full Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
title_fullStr Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
title_full_unstemmed Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
title_sort Optimization of New Sample Preparation Technique for the Determination of Methadone and Codeine in Plasma Sample by GC-FID
author Jamil,Lazgin A.
author_facet Jamil,Lazgin A.
author_role author
dc.contributor.author.fl_str_mv Jamil,Lazgin A.
dc.subject.por.fl_str_mv methadone
codeine
continuous sample drop flow microextraction
gas chromatography
topic methadone
codeine
continuous sample drop flow microextraction
gas chromatography
description A continuous sample drop flow microextraction (CSDF-ME) technique was modified for the pretreatment of plasma samples in the determination of methadone and codeine. The limit of detection and linear range for methadone were 15.0 µg L-1 and 0.1-10.0 mg L-1, respectively. The detection limit and linear range for codeine were 25.0 µg L-1 and 0.2-15.0 mg L-1, respectively. The extraction recoveries were 41.6-52.1%, and the enrichment factors ranged from 65 to 80 for codeine and methadone, respectively. Intra- and interday precisions of the technique were calculated for codeine and methadone concentrations of 0.4 mg L-1 and were 4.2-7.6% and 2.5-5.1%, respectively. Also, the accuracy (error%) of method was in the range -10 to +7.5%. The applicability of the CSDF-ME-gas chromatography-flame ionization detector (GC-FID) technique was illustrated by the determination of the mentioned drugs in human plasma. The attained relative recoveries of methadone and codeine in the 90.0-107.5% range demonstrated the excellent capability of the optimized technique for the microextraction of the mentioned drugs from plasma. The CSDF-ME-GC-FID is a rapid, repeatable and very simple technique that requires a low sample amount.
publishDate 2020
dc.date.none.fl_str_mv 2020-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020000300580
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532020000300580
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21577/0103-5053.20190220
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.31 n.3 2020
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318182654017536