Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K

Detalhes bibliográficos
Autor(a) principal: Augusto,Amanda S.
Data de Publicação: 2019
Outros Autores: Castro,Jeyne P., Sperança,Marco A., Pereira-Filho,Edenir R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000400804
Resumo: This study describes the application of laser-induced breakdown spectroscopy (LIBS) for the direct determination of Ca, K and Mg in powdered dietary supplements. Multi-energy calibration (MEC) method was applied to obtain a calibration curve. With MEC, it was possible to observe spectral interferences and select adequate emission lines from LIBS. For Ca and Mg, five lines were selected and for K just two lines among four could be selected (compromising the results). The trueness for dietary supplements ranged from 81 to 103% for Ca and 74 to 106% for Mg. For K, just the samples S3 (95%) and S5 (109%) showed acceptable trueness values. In the case of Ca and K, besides the MEC, the normalization using C as internal standard also improved the figure of merit results. The MEC and normalization processes showed that possible matrix effect and spectral interferences could be avoided, and the results of trueness and precision were satisfactory.
id SBQ-2_32c3ec751f3da3462ea736da4bd37f51
oai_identifier_str oai:scielo:S0103-50532019000400804
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and Kmulti-energy calibrationdirect solid analysisdietary supplementsLIBSmacronutrients determinationThis study describes the application of laser-induced breakdown spectroscopy (LIBS) for the direct determination of Ca, K and Mg in powdered dietary supplements. Multi-energy calibration (MEC) method was applied to obtain a calibration curve. With MEC, it was possible to observe spectral interferences and select adequate emission lines from LIBS. For Ca and Mg, five lines were selected and for K just two lines among four could be selected (compromising the results). The trueness for dietary supplements ranged from 81 to 103% for Ca and 74 to 106% for Mg. For K, just the samples S3 (95%) and S5 (109%) showed acceptable trueness values. In the case of Ca and K, besides the MEC, the normalization using C as internal standard also improved the figure of merit results. The MEC and normalization processes showed that possible matrix effect and spectral interferences could be avoided, and the results of trueness and precision were satisfactory.Sociedade Brasileira de Química2019-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000400804Journal of the Brazilian Chemical Society v.30 n.4 2019reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20180211info:eu-repo/semantics/openAccessAugusto,Amanda S.Castro,Jeyne P.Sperança,Marco A.Pereira-Filho,Edenir R.eng2019-03-12T00:00:00Zoai:scielo:S0103-50532019000400804Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2019-03-12T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
title Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
spellingShingle Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
Augusto,Amanda S.
multi-energy calibration
direct solid analysis
dietary supplements
LIBS
macronutrients determination
title_short Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
title_full Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
title_fullStr Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
title_full_unstemmed Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
title_sort Combination of Multi-Energy Calibration (MEC) and Laser-Induced Breakdown Spectroscopy (LIBS) for Dietary Supplements Analysis and Determination of Ca, Mg and K
author Augusto,Amanda S.
author_facet Augusto,Amanda S.
Castro,Jeyne P.
Sperança,Marco A.
Pereira-Filho,Edenir R.
author_role author
author2 Castro,Jeyne P.
Sperança,Marco A.
Pereira-Filho,Edenir R.
author2_role author
author
author
dc.contributor.author.fl_str_mv Augusto,Amanda S.
Castro,Jeyne P.
Sperança,Marco A.
Pereira-Filho,Edenir R.
dc.subject.por.fl_str_mv multi-energy calibration
direct solid analysis
dietary supplements
LIBS
macronutrients determination
topic multi-energy calibration
direct solid analysis
dietary supplements
LIBS
macronutrients determination
description This study describes the application of laser-induced breakdown spectroscopy (LIBS) for the direct determination of Ca, K and Mg in powdered dietary supplements. Multi-energy calibration (MEC) method was applied to obtain a calibration curve. With MEC, it was possible to observe spectral interferences and select adequate emission lines from LIBS. For Ca and Mg, five lines were selected and for K just two lines among four could be selected (compromising the results). The trueness for dietary supplements ranged from 81 to 103% for Ca and 74 to 106% for Mg. For K, just the samples S3 (95%) and S5 (109%) showed acceptable trueness values. In the case of Ca and K, besides the MEC, the normalization using C as internal standard also improved the figure of merit results. The MEC and normalization processes showed that possible matrix effect and spectral interferences could be avoided, and the results of trueness and precision were satisfactory.
publishDate 2019
dc.date.none.fl_str_mv 2019-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000400804
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532019000400804
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21577/0103-5053.20180211
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.30 n.4 2019
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318181688279040