Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage
Autor(a) principal: | |
---|---|
Data de Publicação: | 2009 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532009001000012 |
Resumo: | The formation of hexanal, pentanal and malonaldehyde from raw and grilled chicken patties during storage at -18 ºC for 90 days was evaluated by SPME using a DVB/CAR/PDMS fiber. The extraction conditions were optimized to provide reproducible results and avoided fiber saturation even for more oxidised samples. The performance of different DVB/CAR/PDMS fibers was verified during the entire storage period and seven separate fibers were used to assay the extent of lipid oxidation. The relative standard deviation (RSD) was calculated for 60 duplicate analysis and no differences were observed (p > 0.05) among the fibers RSD despite the number of times they were used. The relationship between the different parameters were also established and compared to the results obtained by the traditional TBARS test. Raw patties showed significant (p < 0.05) Pearson's correlations between all parameters, varying from 0.93 to 0.99. However, grilled patties presented a correlation of 0.98 only between hexanal and pentanal. |
id |
SBQ-2_332de0a3df79a6af5edd441b63488065 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532009001000012 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storagelong term storagelipid oxidationTBARSSPMEchicken meatThe formation of hexanal, pentanal and malonaldehyde from raw and grilled chicken patties during storage at -18 ºC for 90 days was evaluated by SPME using a DVB/CAR/PDMS fiber. The extraction conditions were optimized to provide reproducible results and avoided fiber saturation even for more oxidised samples. The performance of different DVB/CAR/PDMS fibers was verified during the entire storage period and seven separate fibers were used to assay the extent of lipid oxidation. The relative standard deviation (RSD) was calculated for 60 duplicate analysis and no differences were observed (p > 0.05) among the fibers RSD despite the number of times they were used. The relationship between the different parameters were also established and compared to the results obtained by the traditional TBARS test. Raw patties showed significant (p < 0.05) Pearson's correlations between all parameters, varying from 0.93 to 0.99. However, grilled patties presented a correlation of 0.98 only between hexanal and pentanal.Sociedade Brasileira de Química2009-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532009001000012Journal of the Brazilian Chemical Society v.20 n.10 2009reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532009001000012info:eu-repo/semantics/openAccessMariutti,Lilian R. B.Nogueira,Gislaine C.Bragagnolo,Neuraeng2011-10-14T00:00:00Zoai:scielo:S0103-50532009001000012Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2011-10-14T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage |
title |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage |
spellingShingle |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage Mariutti,Lilian R. B. long term storage lipid oxidation TBARS SPME chicken meat |
title_short |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage |
title_full |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage |
title_fullStr |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage |
title_full_unstemmed |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage |
title_sort |
Solid phase microextraction - gas chromatography for the evaluation of secondary lipid oxidation products in chicken patties during long-term storage |
author |
Mariutti,Lilian R. B. |
author_facet |
Mariutti,Lilian R. B. Nogueira,Gislaine C. Bragagnolo,Neura |
author_role |
author |
author2 |
Nogueira,Gislaine C. Bragagnolo,Neura |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Mariutti,Lilian R. B. Nogueira,Gislaine C. Bragagnolo,Neura |
dc.subject.por.fl_str_mv |
long term storage lipid oxidation TBARS SPME chicken meat |
topic |
long term storage lipid oxidation TBARS SPME chicken meat |
description |
The formation of hexanal, pentanal and malonaldehyde from raw and grilled chicken patties during storage at -18 ºC for 90 days was evaluated by SPME using a DVB/CAR/PDMS fiber. The extraction conditions were optimized to provide reproducible results and avoided fiber saturation even for more oxidised samples. The performance of different DVB/CAR/PDMS fibers was verified during the entire storage period and seven separate fibers were used to assay the extent of lipid oxidation. The relative standard deviation (RSD) was calculated for 60 duplicate analysis and no differences were observed (p > 0.05) among the fibers RSD despite the number of times they were used. The relationship between the different parameters were also established and compared to the results obtained by the traditional TBARS test. Raw patties showed significant (p < 0.05) Pearson's correlations between all parameters, varying from 0.93 to 0.99. However, grilled patties presented a correlation of 0.98 only between hexanal and pentanal. |
publishDate |
2009 |
dc.date.none.fl_str_mv |
2009-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532009001000012 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532009001000012 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532009001000012 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.20 n.10 2009 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318170300743680 |