Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018001002137 |
Resumo: | A solid-phase extraction (SPE) method based on conductive polypyrrole (PPy) nanofibers which were fabricated by electrospinning and in situ polymerization was developed. PPy nanofibers-mediated SPE followed by high performance liquid chromatography (HPLC) was used for the determination of three synthetic estrogens, namely diethylstilbestrol (DES), dienestrol (DIS), or hexestrol (HS) in milk sample. Extraction conditions including extraction nanofibers, donor solution pH and salt concentration were optimized. The target compounds were extracted from a 0.5 mL aqueous sample at pH 5.0 through PPy fibers, and then were eluted with 0.1 mL methanol. After extraction, the eluant was directly injected into an HPLC system for detection. Under the optimized extraction conditions, a large enrichment factor was achieved for three estrogens. The limit of detection (LOD) at a signal to noise ratio (S/N) of 3 ranged from 0.02 to 0.05 µg mL-1 for the estrogens in milk sample. |
id |
SBQ-2_378664708440da5dab3e1be5ad798340 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532018001002137 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatographyliquid dairy productspacked-fibers solid-phase extractionhigh performance liquid chromatographyestrogensA solid-phase extraction (SPE) method based on conductive polypyrrole (PPy) nanofibers which were fabricated by electrospinning and in situ polymerization was developed. PPy nanofibers-mediated SPE followed by high performance liquid chromatography (HPLC) was used for the determination of three synthetic estrogens, namely diethylstilbestrol (DES), dienestrol (DIS), or hexestrol (HS) in milk sample. Extraction conditions including extraction nanofibers, donor solution pH and salt concentration were optimized. The target compounds were extracted from a 0.5 mL aqueous sample at pH 5.0 through PPy fibers, and then were eluted with 0.1 mL methanol. After extraction, the eluant was directly injected into an HPLC system for detection. Under the optimized extraction conditions, a large enrichment factor was achieved for three estrogens. The limit of detection (LOD) at a signal to noise ratio (S/N) of 3 ranged from 0.02 to 0.05 µg mL-1 for the estrogens in milk sample.Sociedade Brasileira de Química2018-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018001002137Journal of the Brazilian Chemical Society v.29 n.10 2018reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20180088info:eu-repo/semantics/openAccessWei,LanlanYan,YanDeng,JianjunMa,YuqinWang,YuWu,XiaoxiaoKang,Xuejuneng2018-09-21T00:00:00Zoai:scielo:S0103-50532018001002137Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2018-09-21T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography |
title |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography |
spellingShingle |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography Wei,Lanlan liquid dairy products packed-fibers solid-phase extraction high performance liquid chromatography estrogens |
title_short |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography |
title_full |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography |
title_fullStr |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography |
title_full_unstemmed |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography |
title_sort |
Determination of Estrogens in Milk Using Polypyrrole Fiber-Mediated Solid-Phase Extraction Followed by High Performance Liquid Chromatography |
author |
Wei,Lanlan |
author_facet |
Wei,Lanlan Yan,Yan Deng,Jianjun Ma,Yuqin Wang,Yu Wu,Xiaoxiao Kang,Xuejun |
author_role |
author |
author2 |
Yan,Yan Deng,Jianjun Ma,Yuqin Wang,Yu Wu,Xiaoxiao Kang,Xuejun |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Wei,Lanlan Yan,Yan Deng,Jianjun Ma,Yuqin Wang,Yu Wu,Xiaoxiao Kang,Xuejun |
dc.subject.por.fl_str_mv |
liquid dairy products packed-fibers solid-phase extraction high performance liquid chromatography estrogens |
topic |
liquid dairy products packed-fibers solid-phase extraction high performance liquid chromatography estrogens |
description |
A solid-phase extraction (SPE) method based on conductive polypyrrole (PPy) nanofibers which were fabricated by electrospinning and in situ polymerization was developed. PPy nanofibers-mediated SPE followed by high performance liquid chromatography (HPLC) was used for the determination of three synthetic estrogens, namely diethylstilbestrol (DES), dienestrol (DIS), or hexestrol (HS) in milk sample. Extraction conditions including extraction nanofibers, donor solution pH and salt concentration were optimized. The target compounds were extracted from a 0.5 mL aqueous sample at pH 5.0 through PPy fibers, and then were eluted with 0.1 mL methanol. After extraction, the eluant was directly injected into an HPLC system for detection. Under the optimized extraction conditions, a large enrichment factor was achieved for three estrogens. The limit of detection (LOD) at a signal to noise ratio (S/N) of 3 ranged from 0.02 to 0.05 µg mL-1 for the estrogens in milk sample. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018001002137 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018001002137 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.21577/0103-5053.20180088 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.29 n.10 2018 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318181220614144 |