Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan

Detalhes bibliográficos
Autor(a) principal: Chiapetta,Simone C.
Data de Publicação: 2011
Outros Autores: Oliveira,Érika C. B. de, Olivier,Beta C., Mercante,Luiza A., Henriques,Danielle M., Pereira Netto,Annibal D.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011001000012
Resumo: Benzalkonium chloride (BAC), chlorhexidine digluconate (CD) and triclosan (TR) are widely used antimicrobial agents since they are antiseptics and disinfectants depending on the used concentration. The objective of this work was the development of methodology for the fast and simultaneous determination of CD, TR and the BAC homologues (C12, C14 and C16) using HPLC-UV-DAD. Two isocratic reverse-phase systems were optimized: system C8 - column SB-C8 (250 × 4.6 mm; 5 µm) using a mobile phase composed of ACN and H3PO4/NaH2PO4 buffer 0.03 mol L-1, pH 2.0 (80:20, v/v); 2.0 mL min-1 and system CN - column SB-CN (150 × 4.6 mm; 5 µm) using a mobile phase composed of ACN and HOAc/NaOAc buffer 0.1 mol L-1, pH 5.0 (70:30, v/v); 2.0 mL min-1. In both systems the total analysis time was lower than 6 min, leading to high throughput and low production of solvent rejects. Linear ranges with two magnitude orders were found for the five substances in both systems. The sensitivity of system C8 for the five substances was around 20% greater than that of system CN. Both chromatographic methods showed overall precisions better than 4.5%, good resolutions (R > 1.8) and high recoveries (96 to 103%). The limits of quantification were adequate for the determination of the five compounds in commercial products. The analysis of several commercial products showed a good agreement between both chromatographic methods. Good agreement among measured concentrations and labeled values was also observed.
id SBQ-2_56ebd706ae25cdbf993686b5b3899723
oai_identifier_str oai:scielo:S0103-50532011001000012
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosanbenzalkonium chloridechlorexidine digluconatetriclosanmethod validationpersonal care productsBenzalkonium chloride (BAC), chlorhexidine digluconate (CD) and triclosan (TR) are widely used antimicrobial agents since they are antiseptics and disinfectants depending on the used concentration. The objective of this work was the development of methodology for the fast and simultaneous determination of CD, TR and the BAC homologues (C12, C14 and C16) using HPLC-UV-DAD. Two isocratic reverse-phase systems were optimized: system C8 - column SB-C8 (250 × 4.6 mm; 5 µm) using a mobile phase composed of ACN and H3PO4/NaH2PO4 buffer 0.03 mol L-1, pH 2.0 (80:20, v/v); 2.0 mL min-1 and system CN - column SB-CN (150 × 4.6 mm; 5 µm) using a mobile phase composed of ACN and HOAc/NaOAc buffer 0.1 mol L-1, pH 5.0 (70:30, v/v); 2.0 mL min-1. In both systems the total analysis time was lower than 6 min, leading to high throughput and low production of solvent rejects. Linear ranges with two magnitude orders were found for the five substances in both systems. The sensitivity of system C8 for the five substances was around 20% greater than that of system CN. Both chromatographic methods showed overall precisions better than 4.5%, good resolutions (R > 1.8) and high recoveries (96 to 103%). The limits of quantification were adequate for the determination of the five compounds in commercial products. The analysis of several commercial products showed a good agreement between both chromatographic methods. Good agreement among measured concentrations and labeled values was also observed.Sociedade Brasileira de Química2011-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011001000012Journal of the Brazilian Chemical Society v.22 n.10 2011reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532011001000012info:eu-repo/semantics/openAccessChiapetta,Simone C.Oliveira,Érika C. B. deOlivier,Beta C.Mercante,Luiza A.Henriques,Danielle M.Pereira Netto,Annibal D.eng2011-10-25T00:00:00Zoai:scielo:S0103-50532011001000012Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2011-10-25T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
title Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
spellingShingle Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
Chiapetta,Simone C.
benzalkonium chloride
chlorexidine digluconate
triclosan
method validation
personal care products
title_short Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
title_full Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
title_fullStr Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
title_full_unstemmed Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
title_sort Intralaboratory validation, comparison and application of HPLC-UV-DAD methods for simultaneous determination of benzalkonium chloride, chlorexidine digluconate and triclosan
author Chiapetta,Simone C.
author_facet Chiapetta,Simone C.
Oliveira,Érika C. B. de
Olivier,Beta C.
Mercante,Luiza A.
Henriques,Danielle M.
Pereira Netto,Annibal D.
author_role author
author2 Oliveira,Érika C. B. de
Olivier,Beta C.
Mercante,Luiza A.
Henriques,Danielle M.
Pereira Netto,Annibal D.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Chiapetta,Simone C.
Oliveira,Érika C. B. de
Olivier,Beta C.
Mercante,Luiza A.
Henriques,Danielle M.
Pereira Netto,Annibal D.
dc.subject.por.fl_str_mv benzalkonium chloride
chlorexidine digluconate
triclosan
method validation
personal care products
topic benzalkonium chloride
chlorexidine digluconate
triclosan
method validation
personal care products
description Benzalkonium chloride (BAC), chlorhexidine digluconate (CD) and triclosan (TR) are widely used antimicrobial agents since they are antiseptics and disinfectants depending on the used concentration. The objective of this work was the development of methodology for the fast and simultaneous determination of CD, TR and the BAC homologues (C12, C14 and C16) using HPLC-UV-DAD. Two isocratic reverse-phase systems were optimized: system C8 - column SB-C8 (250 × 4.6 mm; 5 µm) using a mobile phase composed of ACN and H3PO4/NaH2PO4 buffer 0.03 mol L-1, pH 2.0 (80:20, v/v); 2.0 mL min-1 and system CN - column SB-CN (150 × 4.6 mm; 5 µm) using a mobile phase composed of ACN and HOAc/NaOAc buffer 0.1 mol L-1, pH 5.0 (70:30, v/v); 2.0 mL min-1. In both systems the total analysis time was lower than 6 min, leading to high throughput and low production of solvent rejects. Linear ranges with two magnitude orders were found for the five substances in both systems. The sensitivity of system C8 for the five substances was around 20% greater than that of system CN. Both chromatographic methods showed overall precisions better than 4.5%, good resolutions (R > 1.8) and high recoveries (96 to 103%). The limits of quantification were adequate for the determination of the five compounds in commercial products. The analysis of several commercial products showed a good agreement between both chromatographic methods. Good agreement among measured concentrations and labeled values was also observed.
publishDate 2011
dc.date.none.fl_str_mv 2011-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011001000012
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011001000012
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532011001000012
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.22 n.10 2011
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318172694642688