Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000800012 |
Resumo: | Levobunolol HCl is a potent non-selective ß-adrenoceptor blocking agent used for the topical treatment of increased intraocular pressure in patients with chronic open angle glaucoma or ocular hypertension. Precise, rapid and extraction-free square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV) method has been described for trace quantitation of levobunolol HCl in bulk form, commercial formulation (ophthalmologic drops) and human serum. Limits of quantification (LOQ) of 1.0 × 10-10 mol L-1 (in bulk form) and 2.5 × 10-10 mol L-1 levobunolol HCl (in spiked human serum) were achieved by the described method. Insignificant interferences from excipients associated with formulation of levobunolol HCl and from some common metal ions, co-administrated drugs, some other ß-blocker agents and its metabolite dihydrolevobunolol that are likely to be present in the biological fluids were obtained. The described SW-AdCSV method is sensitive enough to assay the drug in human serum compared to most of the reported methods. |
id |
SBQ-2_5797b6a43c432c8aad021caa7eae827c |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532014000800012 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrodelevobunolol HClelectrode reactiondeterminationstripping voltammetryLevobunolol HCl is a potent non-selective ß-adrenoceptor blocking agent used for the topical treatment of increased intraocular pressure in patients with chronic open angle glaucoma or ocular hypertension. Precise, rapid and extraction-free square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV) method has been described for trace quantitation of levobunolol HCl in bulk form, commercial formulation (ophthalmologic drops) and human serum. Limits of quantification (LOQ) of 1.0 × 10-10 mol L-1 (in bulk form) and 2.5 × 10-10 mol L-1 levobunolol HCl (in spiked human serum) were achieved by the described method. Insignificant interferences from excipients associated with formulation of levobunolol HCl and from some common metal ions, co-administrated drugs, some other ß-blocker agents and its metabolite dihydrolevobunolol that are likely to be present in the biological fluids were obtained. The described SW-AdCSV method is sensitive enough to assay the drug in human serum compared to most of the reported methods.Sociedade Brasileira de Química2014-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000800012Journal of the Brazilian Chemical Society v.25 n.8 2014reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20140123info:eu-repo/semantics/openAccessGhoneim,Mohamed M.Abdel-Azzem,Magdi K.El-Desoky,Hanaa S.Ghoneim,Ahmed M.Khattab,Ahmed E.eng2014-08-04T00:00:00Zoai:scielo:S0103-50532014000800012Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2014-08-04T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode |
title |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode |
spellingShingle |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode Ghoneim,Mohamed M. levobunolol HCl electrode reaction determination stripping voltammetry |
title_short |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode |
title_full |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode |
title_fullStr |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode |
title_full_unstemmed |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode |
title_sort |
Electrochemical reduction and stripping voltammetric determination of the anti-glaucoma drug levobunolol HCl in formulation and human serum at the mercury electrode |
author |
Ghoneim,Mohamed M. |
author_facet |
Ghoneim,Mohamed M. Abdel-Azzem,Magdi K. El-Desoky,Hanaa S. Ghoneim,Ahmed M. Khattab,Ahmed E. |
author_role |
author |
author2 |
Abdel-Azzem,Magdi K. El-Desoky,Hanaa S. Ghoneim,Ahmed M. Khattab,Ahmed E. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Ghoneim,Mohamed M. Abdel-Azzem,Magdi K. El-Desoky,Hanaa S. Ghoneim,Ahmed M. Khattab,Ahmed E. |
dc.subject.por.fl_str_mv |
levobunolol HCl electrode reaction determination stripping voltammetry |
topic |
levobunolol HCl electrode reaction determination stripping voltammetry |
description |
Levobunolol HCl is a potent non-selective ß-adrenoceptor blocking agent used for the topical treatment of increased intraocular pressure in patients with chronic open angle glaucoma or ocular hypertension. Precise, rapid and extraction-free square-wave adsorptive cathodic stripping voltammetry (SW-AdCSV) method has been described for trace quantitation of levobunolol HCl in bulk form, commercial formulation (ophthalmologic drops) and human serum. Limits of quantification (LOQ) of 1.0 × 10-10 mol L-1 (in bulk form) and 2.5 × 10-10 mol L-1 levobunolol HCl (in spiked human serum) were achieved by the described method. Insignificant interferences from excipients associated with formulation of levobunolol HCl and from some common metal ions, co-administrated drugs, some other ß-blocker agents and its metabolite dihydrolevobunolol that are likely to be present in the biological fluids were obtained. The described SW-AdCSV method is sensitive enough to assay the drug in human serum compared to most of the reported methods. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000800012 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000800012 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0103-5053.20140123 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.25 n.8 2014 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318176182206464 |