International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000600015 |
Resumo: | Initially, for acquiring experience in determining the purity of the dichromate by coulometry, a bilateral comparison between the national metrology institutes (NMIs) from Brazil and Russia was carried out. Next, to evaluate the comparability of the measurement results among the NMIs that use high-precison constant-current coulometry for certifying reference materials (RMs) of pure compounds, National Institute of Metrology, Quality and Technology (Inmetro) participated in a key-comparison named CCQM-K96. Because of both comparisons, a batch of the RM of K2Cr2O7 was certified. This work aims to present the international comparison results, as well as the studies needed to develop a certified reference material (CRM) of K2Cr2O7 for redox titrations. In the certification of the batch, studies of homogeneity and characterization were considered. The K2Cr2O7 batch was certified in mass fraction of 99.974% ± 0.011%, for k = 2 and coverage probability of approximately 95%. |
id |
SBQ-2_71926dc8c43d277102239f1cc4a0875a |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532014000600015 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titrationcertified reference materialprecise coulometric titrationpotassium dichromatecomparabilityInitially, for acquiring experience in determining the purity of the dichromate by coulometry, a bilateral comparison between the national metrology institutes (NMIs) from Brazil and Russia was carried out. Next, to evaluate the comparability of the measurement results among the NMIs that use high-precison constant-current coulometry for certifying reference materials (RMs) of pure compounds, National Institute of Metrology, Quality and Technology (Inmetro) participated in a key-comparison named CCQM-K96. Because of both comparisons, a batch of the RM of K2Cr2O7 was certified. This work aims to present the international comparison results, as well as the studies needed to develop a certified reference material (CRM) of K2Cr2O7 for redox titrations. In the certification of the batch, studies of homogeneity and characterization were considered. The K2Cr2O7 batch was certified in mass fraction of 99.974% ± 0.011%, for k = 2 and coverage probability of approximately 95%.Sociedade Brasileira de Química2014-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000600015Journal of the Brazilian Chemical Society v.25 n.6 2014reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20140086info:eu-repo/semantics/openAccessBorges,Paulo P.Silva Junior,Wiler B. daeng2014-07-01T00:00:00Zoai:scielo:S0103-50532014000600015Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2014-07-01T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration |
title |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration |
spellingShingle |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration Borges,Paulo P. certified reference material precise coulometric titration potassium dichromate comparability |
title_short |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration |
title_full |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration |
title_fullStr |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration |
title_full_unstemmed |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration |
title_sort |
International comparisons for coulometric determinations of dichromate used to develop certified reference material for oxidation-reduction titration |
author |
Borges,Paulo P. |
author_facet |
Borges,Paulo P. Silva Junior,Wiler B. da |
author_role |
author |
author2 |
Silva Junior,Wiler B. da |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Borges,Paulo P. Silva Junior,Wiler B. da |
dc.subject.por.fl_str_mv |
certified reference material precise coulometric titration potassium dichromate comparability |
topic |
certified reference material precise coulometric titration potassium dichromate comparability |
description |
Initially, for acquiring experience in determining the purity of the dichromate by coulometry, a bilateral comparison between the national metrology institutes (NMIs) from Brazil and Russia was carried out. Next, to evaluate the comparability of the measurement results among the NMIs that use high-precison constant-current coulometry for certifying reference materials (RMs) of pure compounds, National Institute of Metrology, Quality and Technology (Inmetro) participated in a key-comparison named CCQM-K96. Because of both comparisons, a batch of the RM of K2Cr2O7 was certified. This work aims to present the international comparison results, as well as the studies needed to develop a certified reference material (CRM) of K2Cr2O7 for redox titrations. In the certification of the batch, studies of homogeneity and characterization were considered. The K2Cr2O7 batch was certified in mass fraction of 99.974% ± 0.011%, for k = 2 and coverage probability of approximately 95%. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000600015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532014000600015 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0103-5053.20140086 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.25 n.6 2014 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318176125583360 |