Resumo: Coulometry is considered the highest metrological method for measuring the amount of substance of high-purity compounds. However, the contamination of the high purity salts is present in trace levels and its identification and quantification are necessary. This work aims to present the studies performed by Inmetro (National Institute of Metrology, Standardization and Industrial Quality, Brazil) to determine the purity of potassium chloride (KCl) by constant-current coulometric titration, as well as the determination of bromide as the main impurity in the KCl through ion chromatography (IC). These studies were needed to develop certified reference material (CRM) of KCl to guarantee the quality of the chemical measurements, mainly those performed by titrimetric analysis. The characterization of the candidate CRM of KCl by coulometric titration presented the purity of 99.9662%. This value was obtained after bromide correction of 182.47 ± 3.03 mg kg-1 (expanded uncertainty for k = 2, for a confidence level of approximately 95%) for the mass fraction bromide assayed by IC.
id SBQ-2_7e77397822ebe3199a30f54994c54eb9
oai_identifier_str oai:scielo:S0103-50532011001000014
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloridecoulometryion chromatographypotassium chloridebromidecertified reference materialCoulometry is considered the highest metrological method for measuring the amount of substance of high-purity compounds. However, the contamination of the high purity salts is present in trace levels and its identification and quantification are necessary. This work aims to present the studies performed by Inmetro (National Institute of Metrology, Standardization and Industrial Quality, Brazil) to determine the purity of potassium chloride (KCl) by constant-current coulometric titration, as well as the determination of bromide as the main impurity in the KCl through ion chromatography (IC). These studies were needed to develop certified reference material (CRM) of KCl to guarantee the quality of the chemical measurements, mainly those performed by titrimetric analysis. The characterization of the candidate CRM of KCl by coulometric titration presented the purity of 99.9662%. This value was obtained after bromide correction of 182.47 ± 3.03 mg kg-1 (expanded uncertainty for k = 2, for a confidence level of approximately 95%) for the mass fraction bromide assayed by IC.Sociedade Brasileira de Química2011-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011001000014Journal of the Brazilian Chemical Society v.22 n.10 2011reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532011001000014info:eu-repo/semantics/openAccessBorges,Paulo P.Sobral,Sidney P.Silva,Lilian daAraújo,Thiago O.Silva,Renata S.eng2011-10-25T00:00:00Zoai:scielo:S0103-50532011001000014Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2011-10-25T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
title Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
spellingShingle Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
Borges,Paulo P.
coulometry
ion chromatography
potassium chloride
bromide
certified reference material
title_short Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
title_full Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
title_fullStr Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
title_full_unstemmed Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
title_sort Constant-current coulometry and ion chromatography bromide determination to characterize the purity of the potassium chloride
author Borges,Paulo P.
author_facet Borges,Paulo P.
Sobral,Sidney P.
Silva,Lilian da
Araújo,Thiago O.
Silva,Renata S.
author_role author
author2 Sobral,Sidney P.
Silva,Lilian da
Araújo,Thiago O.
Silva,Renata S.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Borges,Paulo P.
Sobral,Sidney P.
Silva,Lilian da
Araújo,Thiago O.
Silva,Renata S.
dc.subject.por.fl_str_mv coulometry
ion chromatography
potassium chloride
bromide
certified reference material
topic coulometry
ion chromatography
potassium chloride
bromide
certified reference material
description Coulometry is considered the highest metrological method for measuring the amount of substance of high-purity compounds. However, the contamination of the high purity salts is present in trace levels and its identification and quantification are necessary. This work aims to present the studies performed by Inmetro (National Institute of Metrology, Standardization and Industrial Quality, Brazil) to determine the purity of potassium chloride (KCl) by constant-current coulometric titration, as well as the determination of bromide as the main impurity in the KCl through ion chromatography (IC). These studies were needed to develop certified reference material (CRM) of KCl to guarantee the quality of the chemical measurements, mainly those performed by titrimetric analysis. The characterization of the candidate CRM of KCl by coulometric titration presented the purity of 99.9662%. This value was obtained after bromide correction of 182.47 ± 3.03 mg kg-1 (expanded uncertainty for k = 2, for a confidence level of approximately 95%) for the mass fraction bromide assayed by IC.
publishDate 2011
dc.date.none.fl_str_mv 2011-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011001000014
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011001000014
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532011001000014
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.22 n.10 2011
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318172697788416