Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry

Detalhes bibliográficos
Autor(a) principal: Caldas,Sergiane S.
Data de Publicação: 2010
Outros Autores: Demoliner,Adriana, Costa,Fabiane P., D'Oca,Marcelo G. M., Primel,Ednei G.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000400009
Resumo: Residues of four pesticides in groundwaters were surveyed during one year in an agricultural area in southern Brazil. The methods for separation, identification and quantification of the compounds included high-performance liquid chromatography with diode array detection (HPLC-DAD) and liquid chromatography with electrospray interface tandem mass spectrometry (LC-ESI-MS/MS). A pre-concentration step based on solid-phase extraction with 200 mg C18 cartridges was applied. All the analytical parameters were within the limits suggested for the validation of chromatographic methods. The LOQs for the methods, considering the 250-fold pre-concentration step, were 0.2 μg L-1 for all pesticides by HPLC-DAD, 4.0 ng L-1 for clomazone, carbofuran and tebuconazole and 40.0 ng L-1 for 2,4-D by LC-ESI-MS/MS. In groundwater samples, 2,4-D was not detected, and carbofuran, clomazone and tebuconazole were detected in concentrations ranging from 0.25 to 10.40 μg L-1, from 0.20 to 0.82 μg L-1 and from 0.20 to 4.16 μg L-1, respectively. The methods proved to be adequate for the analysis of pesticides in groundwaters.
id SBQ-2_8fc81dc6eefc7ae903326ea9a28246af
oai_identifier_str oai:scielo:S0103-50532010000400009
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometrygroundwaterspesticidesHPLC-DADSPELC-MS/MSResidues of four pesticides in groundwaters were surveyed during one year in an agricultural area in southern Brazil. The methods for separation, identification and quantification of the compounds included high-performance liquid chromatography with diode array detection (HPLC-DAD) and liquid chromatography with electrospray interface tandem mass spectrometry (LC-ESI-MS/MS). A pre-concentration step based on solid-phase extraction with 200 mg C18 cartridges was applied. All the analytical parameters were within the limits suggested for the validation of chromatographic methods. The LOQs for the methods, considering the 250-fold pre-concentration step, were 0.2 μg L-1 for all pesticides by HPLC-DAD, 4.0 ng L-1 for clomazone, carbofuran and tebuconazole and 40.0 ng L-1 for 2,4-D by LC-ESI-MS/MS. In groundwater samples, 2,4-D was not detected, and carbofuran, clomazone and tebuconazole were detected in concentrations ranging from 0.25 to 10.40 μg L-1, from 0.20 to 0.82 μg L-1 and from 0.20 to 4.16 μg L-1, respectively. The methods proved to be adequate for the analysis of pesticides in groundwaters.Sociedade Brasileira de Química2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000400009Journal of the Brazilian Chemical Society v.21 n.4 2010reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532010000400009info:eu-repo/semantics/openAccessCaldas,Sergiane S.Demoliner,AdrianaCosta,Fabiane P.D'Oca,Marcelo G. M.Primel,Ednei G.eng2010-05-21T00:00:00Zoai:scielo:S0103-50532010000400009Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2010-05-21T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
title Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
spellingShingle Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
Caldas,Sergiane S.
groundwaters
pesticides
HPLC-DAD
SPE
LC-MS/MS
title_short Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
title_full Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
title_fullStr Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
title_full_unstemmed Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
title_sort Pesticide residue determination in groundwater using solid-phase extraction and high-performance liquid chromatography with diode array detector and liquid chromatography-tandem mass spectrometry
author Caldas,Sergiane S.
author_facet Caldas,Sergiane S.
Demoliner,Adriana
Costa,Fabiane P.
D'Oca,Marcelo G. M.
Primel,Ednei G.
author_role author
author2 Demoliner,Adriana
Costa,Fabiane P.
D'Oca,Marcelo G. M.
Primel,Ednei G.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Caldas,Sergiane S.
Demoliner,Adriana
Costa,Fabiane P.
D'Oca,Marcelo G. M.
Primel,Ednei G.
dc.subject.por.fl_str_mv groundwaters
pesticides
HPLC-DAD
SPE
LC-MS/MS
topic groundwaters
pesticides
HPLC-DAD
SPE
LC-MS/MS
description Residues of four pesticides in groundwaters were surveyed during one year in an agricultural area in southern Brazil. The methods for separation, identification and quantification of the compounds included high-performance liquid chromatography with diode array detection (HPLC-DAD) and liquid chromatography with electrospray interface tandem mass spectrometry (LC-ESI-MS/MS). A pre-concentration step based on solid-phase extraction with 200 mg C18 cartridges was applied. All the analytical parameters were within the limits suggested for the validation of chromatographic methods. The LOQs for the methods, considering the 250-fold pre-concentration step, were 0.2 μg L-1 for all pesticides by HPLC-DAD, 4.0 ng L-1 for clomazone, carbofuran and tebuconazole and 40.0 ng L-1 for 2,4-D by LC-ESI-MS/MS. In groundwater samples, 2,4-D was not detected, and carbofuran, clomazone and tebuconazole were detected in concentrations ranging from 0.25 to 10.40 μg L-1, from 0.20 to 0.82 μg L-1 and from 0.20 to 4.16 μg L-1, respectively. The methods proved to be adequate for the analysis of pesticides in groundwaters.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000400009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532010000400009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532010000400009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.21 n.4 2010
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318170695008256