Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media

Detalhes bibliográficos
Autor(a) principal: Farhadi,Khalil
Data de Publicação: 2008
Outros Autores: Kheiri,Farshad, Golzan,Mirmaqsoud
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000700026
Resumo: A stable carbon paste electrode (CPE) was prepared with Th(IV)-hexacyanoferrate (Th-HCF) ion pair and its electrochemical behavior was investigated by cyclic voltammetry. The apparent heterogeneous rate constant, k s, and transfer coefficient, a, for electron transfer between Th-HCF ion-pair and CPE were calculated as 3.1 ± 0.1 s-1 and 0.47, respectively. The surface coverage (Γ) of the proposed electrode was calculated as 7.06 × 10-10 mol cm-2. The proposed Th-HCF modified carbon paste electrode (THMCPE) showed a good electrocatalytic behavior with a significant shift toward negative potentials in oxidation of ascorbic acid (AA) and dopamine (DA) in acidic media (phosphate buffer solution, pH 3). The THMCPE exhibited excellent characteristics for simultaneous determination of AA and DA. Amperometric curves using the catalytic currents are linear for DA and AA concentrations in the ranges 8 × 10-6 - 2 × 10-3 and 1 × 10-5 - 2 × 10-3 mol L-1 with detection limits 5.6 × 10-6 mol L-1 and 4.7 × 10-6 mol L-1, respectively. Diffusion coefficients of AA and DA in electrocatalaytic oxidation were calculated from chronoamperometric data.
id SBQ-2_a77e62763280f7b9ee1d69c59d3ce42c
oai_identifier_str oai:scielo:S0103-50532008000700026
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic mediamodified carbon pasteTh(IV)-hexacyanoferrateascorbic aciddopamineA stable carbon paste electrode (CPE) was prepared with Th(IV)-hexacyanoferrate (Th-HCF) ion pair and its electrochemical behavior was investigated by cyclic voltammetry. The apparent heterogeneous rate constant, k s, and transfer coefficient, a, for electron transfer between Th-HCF ion-pair and CPE were calculated as 3.1 ± 0.1 s-1 and 0.47, respectively. The surface coverage (Γ) of the proposed electrode was calculated as 7.06 × 10-10 mol cm-2. The proposed Th-HCF modified carbon paste electrode (THMCPE) showed a good electrocatalytic behavior with a significant shift toward negative potentials in oxidation of ascorbic acid (AA) and dopamine (DA) in acidic media (phosphate buffer solution, pH 3). The THMCPE exhibited excellent characteristics for simultaneous determination of AA and DA. Amperometric curves using the catalytic currents are linear for DA and AA concentrations in the ranges 8 × 10-6 - 2 × 10-3 and 1 × 10-5 - 2 × 10-3 mol L-1 with detection limits 5.6 × 10-6 mol L-1 and 4.7 × 10-6 mol L-1, respectively. Diffusion coefficients of AA and DA in electrocatalaytic oxidation were calculated from chronoamperometric data.Sociedade Brasileira de Química2008-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000700026Journal of the Brazilian Chemical Society v.19 n.7 2008reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532008000700026info:eu-repo/semantics/openAccessFarhadi,KhalilKheiri,FarshadGolzan,Mirmaqsoudeng2017-05-05T00:00:00Zoai:scielo:S0103-50532008000700026Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2017-05-05T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
title Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
spellingShingle Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
Farhadi,Khalil
modified carbon paste
Th(IV)-hexacyanoferrate
ascorbic acid
dopamine
title_short Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
title_full Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
title_fullStr Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
title_full_unstemmed Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
title_sort Th(IV)-hexacyanoferrate modified carbon paste electrode as a new electrocatalytic probe for simultaneous determination of ascorbic acid and dopamine from acidic media
author Farhadi,Khalil
author_facet Farhadi,Khalil
Kheiri,Farshad
Golzan,Mirmaqsoud
author_role author
author2 Kheiri,Farshad
Golzan,Mirmaqsoud
author2_role author
author
dc.contributor.author.fl_str_mv Farhadi,Khalil
Kheiri,Farshad
Golzan,Mirmaqsoud
dc.subject.por.fl_str_mv modified carbon paste
Th(IV)-hexacyanoferrate
ascorbic acid
dopamine
topic modified carbon paste
Th(IV)-hexacyanoferrate
ascorbic acid
dopamine
description A stable carbon paste electrode (CPE) was prepared with Th(IV)-hexacyanoferrate (Th-HCF) ion pair and its electrochemical behavior was investigated by cyclic voltammetry. The apparent heterogeneous rate constant, k s, and transfer coefficient, a, for electron transfer between Th-HCF ion-pair and CPE were calculated as 3.1 ± 0.1 s-1 and 0.47, respectively. The surface coverage (Γ) of the proposed electrode was calculated as 7.06 × 10-10 mol cm-2. The proposed Th-HCF modified carbon paste electrode (THMCPE) showed a good electrocatalytic behavior with a significant shift toward negative potentials in oxidation of ascorbic acid (AA) and dopamine (DA) in acidic media (phosphate buffer solution, pH 3). The THMCPE exhibited excellent characteristics for simultaneous determination of AA and DA. Amperometric curves using the catalytic currents are linear for DA and AA concentrations in the ranges 8 × 10-6 - 2 × 10-3 and 1 × 10-5 - 2 × 10-3 mol L-1 with detection limits 5.6 × 10-6 mol L-1 and 4.7 × 10-6 mol L-1, respectively. Diffusion coefficients of AA and DA in electrocatalaytic oxidation were calculated from chronoamperometric data.
publishDate 2008
dc.date.none.fl_str_mv 2008-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000700026
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000700026
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532008000700026
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.19 n.7 2008
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318169369608192