Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000500963 |
Resumo: | This article describes the fabrication of a novel and selective polyvinylchloride (PVC) membrane potentiometric sensor for Al3+ cation based on 12-crown-4 (12C4) as an ionophore. The electrode was prepared by coating the surface of a graphite rod by a membrane containing PVC as a plastic matrix, dibutylphthalate (DBP) as plasticizer, 12C4 as an ionophore and oleic acid (OA) as an additive. Under optimized membrane composition, the constructed electrochemical sensor exhibited a Nernstian response for Al3+ cation concentration, ranging from 1.0 × 10-6 to 1.0 × 10-1mol L-1with a detection limit of 5.5 × 10-7mol L-1 and a slope of 19.0 ± 0.4 mV per decade at 25 °C. The constructed potentiometric sensor showed a relatively fast response time (15 s), good reproducibility and stability, and high selectivity towards Al3+ cation in solutions. The proposed sensor was successfully used as an indicator electrode in potentiometric titration and also in the direct determination of this metal cation in real samples. |
id |
SBQ-2_b2bce27b72a01a0f040b5ca65970b841 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532015000500963 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophorealuminum(III) cation12-crown-4ion-selective electrodepotentiometryThis article describes the fabrication of a novel and selective polyvinylchloride (PVC) membrane potentiometric sensor for Al3+ cation based on 12-crown-4 (12C4) as an ionophore. The electrode was prepared by coating the surface of a graphite rod by a membrane containing PVC as a plastic matrix, dibutylphthalate (DBP) as plasticizer, 12C4 as an ionophore and oleic acid (OA) as an additive. Under optimized membrane composition, the constructed electrochemical sensor exhibited a Nernstian response for Al3+ cation concentration, ranging from 1.0 × 10-6 to 1.0 × 10-1mol L-1with a detection limit of 5.5 × 10-7mol L-1 and a slope of 19.0 ± 0.4 mV per decade at 25 °C. The constructed potentiometric sensor showed a relatively fast response time (15 s), good reproducibility and stability, and high selectivity towards Al3+ cation in solutions. The proposed sensor was successfully used as an indicator electrode in potentiometric titration and also in the direct determination of this metal cation in real samples.Sociedade Brasileira de Química2015-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000500963Journal of the Brazilian Chemical Society v.26 n.5 2015reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20150058info:eu-repo/semantics/openAccessEsmaelpourfarkhani,MasoomehRounaghi,Gholam H.Arbab-Zavar,Mohammad H.eng2015-10-26T00:00:00Zoai:scielo:S0103-50532015000500963Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2015-10-26T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore |
title |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore |
spellingShingle |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore Esmaelpourfarkhani,Masoomeh aluminum(III) cation 12-crown-4 ion-selective electrode potentiometry |
title_short |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore |
title_full |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore |
title_fullStr |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore |
title_full_unstemmed |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore |
title_sort |
Construction of a New Aluminum(III) Cation Selective Electrode Based on 12-Crown-4 as an Ionophore |
author |
Esmaelpourfarkhani,Masoomeh |
author_facet |
Esmaelpourfarkhani,Masoomeh Rounaghi,Gholam H. Arbab-Zavar,Mohammad H. |
author_role |
author |
author2 |
Rounaghi,Gholam H. Arbab-Zavar,Mohammad H. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Esmaelpourfarkhani,Masoomeh Rounaghi,Gholam H. Arbab-Zavar,Mohammad H. |
dc.subject.por.fl_str_mv |
aluminum(III) cation 12-crown-4 ion-selective electrode potentiometry |
topic |
aluminum(III) cation 12-crown-4 ion-selective electrode potentiometry |
description |
This article describes the fabrication of a novel and selective polyvinylchloride (PVC) membrane potentiometric sensor for Al3+ cation based on 12-crown-4 (12C4) as an ionophore. The electrode was prepared by coating the surface of a graphite rod by a membrane containing PVC as a plastic matrix, dibutylphthalate (DBP) as plasticizer, 12C4 as an ionophore and oleic acid (OA) as an additive. Under optimized membrane composition, the constructed electrochemical sensor exhibited a Nernstian response for Al3+ cation concentration, ranging from 1.0 × 10-6 to 1.0 × 10-1mol L-1with a detection limit of 5.5 × 10-7mol L-1 and a slope of 19.0 ± 0.4 mV per decade at 25 °C. The constructed potentiometric sensor showed a relatively fast response time (15 s), good reproducibility and stability, and high selectivity towards Al3+ cation in solutions. The proposed sensor was successfully used as an indicator electrode in potentiometric titration and also in the direct determination of this metal cation in real samples. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-05-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000500963 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015000500963 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0103-5053.20150058 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.26 n.5 2015 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318177077690368 |