Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC)
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000100015 |
Resumo: | This work presents a method for lead determination by ETAAS, based on solid sampling of polyurethane foam (PUF) impregnated with the reagent 2-(2-thiazolylazo)-p-cresol (TAC) previously utilized to extract the metallic ion from sample solution. The extraction process occurred in a medium buffered in pH 10 with borate system, after 40 min of agitation between the solid and liquid phases. The obtained results showed the easily elimination of the matrix from the graphite tube by a pyrolysis step at 600 ºC, without using of any matrix modifier. The method was validated by analysis of certified materials (biological samples) and by using recovery tests employing saline samples. |
id |
SBQ-2_c7915bb5bc75f66f6f2e1526a0c1be66 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532004000100015 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC)solid phase extractionpolyurethane foamthiazolylazo-p-cresolsolid sampling techniqueleadETAASThis work presents a method for lead determination by ETAAS, based on solid sampling of polyurethane foam (PUF) impregnated with the reagent 2-(2-thiazolylazo)-p-cresol (TAC) previously utilized to extract the metallic ion from sample solution. The extraction process occurred in a medium buffered in pH 10 with borate system, after 40 min of agitation between the solid and liquid phases. The obtained results showed the easily elimination of the matrix from the graphite tube by a pyrolysis step at 600 ºC, without using of any matrix modifier. The method was validated by analysis of certified materials (biological samples) and by using recovery tests employing saline samples.Sociedade Brasileira de Química2004-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000100015Journal of the Brazilian Chemical Society v.15 n.1 2004reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532004000100015info:eu-repo/semantics/openAccessSant'Ana,Otoniel DJesuino,Luciene SCassella,Ricardo JCarvalho,Marcelo SSantelli,Ricardo Eeng2004-05-25T00:00:00Zoai:scielo:S0103-50532004000100015Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2004-05-25T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) |
title |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) |
spellingShingle |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) Sant'Ana,Otoniel D solid phase extraction polyurethane foam thiazolylazo-p-cresol solid sampling technique lead ETAAS |
title_short |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) |
title_full |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) |
title_fullStr |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) |
title_full_unstemmed |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) |
title_sort |
Determination of lead by electrothermal atomic absorption spectrometry employing a novel sampling strategy of polyurethane foam impregnated with thiazolylazo-p-cresol (TAC) |
author |
Sant'Ana,Otoniel D |
author_facet |
Sant'Ana,Otoniel D Jesuino,Luciene S Cassella,Ricardo J Carvalho,Marcelo S Santelli,Ricardo E |
author_role |
author |
author2 |
Jesuino,Luciene S Cassella,Ricardo J Carvalho,Marcelo S Santelli,Ricardo E |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Sant'Ana,Otoniel D Jesuino,Luciene S Cassella,Ricardo J Carvalho,Marcelo S Santelli,Ricardo E |
dc.subject.por.fl_str_mv |
solid phase extraction polyurethane foam thiazolylazo-p-cresol solid sampling technique lead ETAAS |
topic |
solid phase extraction polyurethane foam thiazolylazo-p-cresol solid sampling technique lead ETAAS |
description |
This work presents a method for lead determination by ETAAS, based on solid sampling of polyurethane foam (PUF) impregnated with the reagent 2-(2-thiazolylazo)-p-cresol (TAC) previously utilized to extract the metallic ion from sample solution. The extraction process occurred in a medium buffered in pH 10 with borate system, after 40 min of agitation between the solid and liquid phases. The obtained results showed the easily elimination of the matrix from the graphite tube by a pyrolysis step at 600 ºC, without using of any matrix modifier. The method was validated by analysis of certified materials (biological samples) and by using recovery tests employing saline samples. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000100015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000100015 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532004000100015 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.15 n.1 2004 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318165419622400 |