Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices
Autor(a) principal: | |
---|---|
Data de Publicação: | 2002 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532002000400008 |
Resumo: | A flow system method for continuous determination of phenolic compounds in environmental matrices was employed using a dialysis membrane sampler and laccase- and tyrosinase-based biosensors as detector. The biosensors response to different phenolic compounds was investigated. The laccase-based biosensor showed high sensitivity to guaiacol and chloroguaiacol, while the tyrosinase-based biosensor was more sensitive to phenol and chlorophenol. Both of the biosensors presented highly selective measurements of micromolar concentration of these compounds. Detection limits around 1.1 x 10-7 mol L-1 for guaiacol and 1.9 x 10-7 mol L-1 for chloroguaiacol could be estimated for the laccase-based biosensor. Using the tyrosinase-based biosensor detection limits of 1.5 x 10-7 mol L-1 for phenol and 9.0 x 10-8 mol L-1 for chlorophenol were observed. The proposed flow method presented a linear response range between 1.0 mumol L-1 and 100.0 mumol L-1, in the optimized operational conditions (laccase-based biosensor: pH 5.0 and 0 mV vs Ag/AgCl as working potential; tyrosinase-based biosensor: pH 5.5 and 50 mV vs Ag/AgCl as working potential). Real paper mill effluent sample was analyzed by this system and by the reference colorimetric method and the results were discussed. |
id |
SBQ-2_d557061c7942ea977eadbbdc001c64a2 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532002000400008 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matricesamperometric biosensorscontinuous monitoringenvironmental samplesphenolic compoundsA flow system method for continuous determination of phenolic compounds in environmental matrices was employed using a dialysis membrane sampler and laccase- and tyrosinase-based biosensors as detector. The biosensors response to different phenolic compounds was investigated. The laccase-based biosensor showed high sensitivity to guaiacol and chloroguaiacol, while the tyrosinase-based biosensor was more sensitive to phenol and chlorophenol. Both of the biosensors presented highly selective measurements of micromolar concentration of these compounds. Detection limits around 1.1 x 10-7 mol L-1 for guaiacol and 1.9 x 10-7 mol L-1 for chloroguaiacol could be estimated for the laccase-based biosensor. Using the tyrosinase-based biosensor detection limits of 1.5 x 10-7 mol L-1 for phenol and 9.0 x 10-8 mol L-1 for chlorophenol were observed. The proposed flow method presented a linear response range between 1.0 mumol L-1 and 100.0 mumol L-1, in the optimized operational conditions (laccase-based biosensor: pH 5.0 and 0 mV vs Ag/AgCl as working potential; tyrosinase-based biosensor: pH 5.5 and 50 mV vs Ag/AgCl as working potential). Real paper mill effluent sample was analyzed by this system and by the reference colorimetric method and the results were discussed.Sociedade Brasileira de Química2002-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532002000400008Journal of the Brazilian Chemical Society v.13 n.4 2002reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532002000400008info:eu-repo/semantics/openAccessFreire,Renato S.Durán,NelsonKubota,Lauro T.eng2002-09-06T00:00:00Zoai:scielo:S0103-50532002000400008Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2002-09-06T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices |
title |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices |
spellingShingle |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices Freire,Renato S. amperometric biosensors continuous monitoring environmental samples phenolic compounds |
title_short |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices |
title_full |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices |
title_fullStr |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices |
title_full_unstemmed |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices |
title_sort |
Electrochemical biosensor-based devices for continuous phenols monitoring in environmental matrices |
author |
Freire,Renato S. |
author_facet |
Freire,Renato S. Durán,Nelson Kubota,Lauro T. |
author_role |
author |
author2 |
Durán,Nelson Kubota,Lauro T. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Freire,Renato S. Durán,Nelson Kubota,Lauro T. |
dc.subject.por.fl_str_mv |
amperometric biosensors continuous monitoring environmental samples phenolic compounds |
topic |
amperometric biosensors continuous monitoring environmental samples phenolic compounds |
description |
A flow system method for continuous determination of phenolic compounds in environmental matrices was employed using a dialysis membrane sampler and laccase- and tyrosinase-based biosensors as detector. The biosensors response to different phenolic compounds was investigated. The laccase-based biosensor showed high sensitivity to guaiacol and chloroguaiacol, while the tyrosinase-based biosensor was more sensitive to phenol and chlorophenol. Both of the biosensors presented highly selective measurements of micromolar concentration of these compounds. Detection limits around 1.1 x 10-7 mol L-1 for guaiacol and 1.9 x 10-7 mol L-1 for chloroguaiacol could be estimated for the laccase-based biosensor. Using the tyrosinase-based biosensor detection limits of 1.5 x 10-7 mol L-1 for phenol and 9.0 x 10-8 mol L-1 for chlorophenol were observed. The proposed flow method presented a linear response range between 1.0 mumol L-1 and 100.0 mumol L-1, in the optimized operational conditions (laccase-based biosensor: pH 5.0 and 0 mV vs Ag/AgCl as working potential; tyrosinase-based biosensor: pH 5.5 and 50 mV vs Ag/AgCl as working potential). Real paper mill effluent sample was analyzed by this system and by the reference colorimetric method and the results were discussed. |
publishDate |
2002 |
dc.date.none.fl_str_mv |
2002-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532002000400008 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532002000400008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532002000400008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.13 n.4 2002 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318164914208768 |