A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs

Detalhes bibliográficos
Autor(a) principal: Souza,Flávia C.
Data de Publicação: 2013
Outros Autores: Silva,Davi Augusto I. da, Ribeiro,Márcia S., Faria,Roberto B., Melo,Maria A., Toledo,Roberta M. M., D'Elia,Eliane
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013001000005
Resumo: Amperometric and spectrophotometric methods were developed for measuring iodide tracer concentration in water produced from offshore oil reservoirs. The amperometric method exhibited a linear response from 1 to 10 mg L-1 with limits of detection and of quantification of 0.2 and 0.6 mg L-1, respectively. The spectrophotometric method also exhibited a linear response from 1 to 10 mg L-1 with limits of detection and of quantification of 1 and 3 mg L-1, respectively. Both methods showed to be accurate, linear, homoscedastic and their recoveries were 101 ± 2 and 100 ± 3%, respectively, while the recoveries for produced reservoir water samples (fortified with iodide) were 97 ± 7 and 100 ± 3%, respectively. High amounts of sulfate interfere in the spectrophotometric method. Both methods are promising, simple and inexpensive alternatives to ion chromatography for the detection of iodide tracer in produced water reservoir samples.
id SBQ-2_d861aa34b652cf68d174ca7beb690662
oai_identifier_str oai:scielo:S0103-50532013001000005
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirsiodidereservoir traceramperometryultramicroelectrodespectrophotometryproduced waterAmperometric and spectrophotometric methods were developed for measuring iodide tracer concentration in water produced from offshore oil reservoirs. The amperometric method exhibited a linear response from 1 to 10 mg L-1 with limits of detection and of quantification of 0.2 and 0.6 mg L-1, respectively. The spectrophotometric method also exhibited a linear response from 1 to 10 mg L-1 with limits of detection and of quantification of 1 and 3 mg L-1, respectively. Both methods showed to be accurate, linear, homoscedastic and their recoveries were 101 ± 2 and 100 ± 3%, respectively, while the recoveries for produced reservoir water samples (fortified with iodide) were 97 ± 7 and 100 ± 3%, respectively. High amounts of sulfate interfere in the spectrophotometric method. Both methods are promising, simple and inexpensive alternatives to ion chromatography for the detection of iodide tracer in produced water reservoir samples.Sociedade Brasileira de Química2013-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013001000005Journal of the Brazilian Chemical Society v.24 n.10 2013reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20130199info:eu-repo/semantics/openAccessSouza,Flávia C.Silva,Davi Augusto I. daRibeiro,Márcia S.Faria,Roberto B.Melo,Maria A.Toledo,Roberta M. M.D'Elia,Elianeeng2015-07-21T00:00:00Zoai:scielo:S0103-50532013001000005Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2015-07-21T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
title A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
spellingShingle A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
Souza,Flávia C.
iodide
reservoir tracer
amperometry
ultramicroelectrode
spectrophotometry
produced water
title_short A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
title_full A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
title_fullStr A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
title_full_unstemmed A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
title_sort A comparison of amperometric and spectrophotometric methods for the iodide concentration measurement: a tracer in produced water from offshore oil reservoirs
author Souza,Flávia C.
author_facet Souza,Flávia C.
Silva,Davi Augusto I. da
Ribeiro,Márcia S.
Faria,Roberto B.
Melo,Maria A.
Toledo,Roberta M. M.
D'Elia,Eliane
author_role author
author2 Silva,Davi Augusto I. da
Ribeiro,Márcia S.
Faria,Roberto B.
Melo,Maria A.
Toledo,Roberta M. M.
D'Elia,Eliane
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Souza,Flávia C.
Silva,Davi Augusto I. da
Ribeiro,Márcia S.
Faria,Roberto B.
Melo,Maria A.
Toledo,Roberta M. M.
D'Elia,Eliane
dc.subject.por.fl_str_mv iodide
reservoir tracer
amperometry
ultramicroelectrode
spectrophotometry
produced water
topic iodide
reservoir tracer
amperometry
ultramicroelectrode
spectrophotometry
produced water
description Amperometric and spectrophotometric methods were developed for measuring iodide tracer concentration in water produced from offshore oil reservoirs. The amperometric method exhibited a linear response from 1 to 10 mg L-1 with limits of detection and of quantification of 0.2 and 0.6 mg L-1, respectively. The spectrophotometric method also exhibited a linear response from 1 to 10 mg L-1 with limits of detection and of quantification of 1 and 3 mg L-1, respectively. Both methods showed to be accurate, linear, homoscedastic and their recoveries were 101 ± 2 and 100 ± 3%, respectively, while the recoveries for produced reservoir water samples (fortified with iodide) were 97 ± 7 and 100 ± 3%, respectively. High amounts of sulfate interfere in the spectrophotometric method. Both methods are promising, simple and inexpensive alternatives to ion chromatography for the detection of iodide tracer in produced water reservoir samples.
publishDate 2013
dc.date.none.fl_str_mv 2013-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013001000005
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013001000005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0103-5053.20130199
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.24 n.10 2013
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318175288819712