Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000900007 |
Resumo: | A simple and rapid vortex-assisted ionic liquid based liquid-liquid microextraction (VALLME) procedure was used for the determination of trace amounts of cadmium by flame atomic absorption spectrometry (FAAS). Ionic liquid (IL), 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF]), was used as an extractant solvent. Cd2+ was complexed with ammonium pyrrolidinedithiocarbamate (APDC) and then entered into the fine IL droplets by the assistance of vortex agitator system. Some effective factors that influence the extraction efficiency such as pH, ligand concentration, amount of ionic liquid, extraction time and ionic strength effect were completely investigated and optimized. Under the optimum conditions, the limit of detection (LOD) was 1.1 ng mL-1. The relative standard deviation (RSD) was 4.3% for 20 ng mL-1 of cadmium (n = 10), and the calibration graph using the preconcentration method was linear from 5 to 150 µg L-1, with a correlation coefficient of 0.998. The proposed method was successfully applied for determination of cadmium in water samples and spinach leaves. |
id |
SBQ-2_e0924fda80ca853cccfc3f7aed2a7f5e |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532012000900007 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometrycadmiumammonium pyrroldinedithiocarbamate (APDC)ionic liquidflame atomic absorption spectrometryA simple and rapid vortex-assisted ionic liquid based liquid-liquid microextraction (VALLME) procedure was used for the determination of trace amounts of cadmium by flame atomic absorption spectrometry (FAAS). Ionic liquid (IL), 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF]), was used as an extractant solvent. Cd2+ was complexed with ammonium pyrrolidinedithiocarbamate (APDC) and then entered into the fine IL droplets by the assistance of vortex agitator system. Some effective factors that influence the extraction efficiency such as pH, ligand concentration, amount of ionic liquid, extraction time and ionic strength effect were completely investigated and optimized. Under the optimum conditions, the limit of detection (LOD) was 1.1 ng mL-1. The relative standard deviation (RSD) was 4.3% for 20 ng mL-1 of cadmium (n = 10), and the calibration graph using the preconcentration method was linear from 5 to 150 µg L-1, with a correlation coefficient of 0.998. The proposed method was successfully applied for determination of cadmium in water samples and spinach leaves.Sociedade Brasileira de Química2012-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000900007Journal of the Brazilian Chemical Society v.23 n.9 2012reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532012005000026info:eu-repo/semantics/openAccessChamsaz,MahmoudEftekhari,MohammadAtarodi,AtefeAsadpour,SaeidAriani,Maraleng2012-10-15T00:00:00Zoai:scielo:S0103-50532012000900007Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2012-10-15T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry |
title |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry |
spellingShingle |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry Chamsaz,Mahmoud cadmium ammonium pyrroldinedithiocarbamate (APDC) ionic liquid flame atomic absorption spectrometry |
title_short |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry |
title_full |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry |
title_fullStr |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry |
title_full_unstemmed |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry |
title_sort |
Preconcentration procedure using vortex agitator system for determination of trace levels of cadmium by flame atomic absorption spectrometry |
author |
Chamsaz,Mahmoud |
author_facet |
Chamsaz,Mahmoud Eftekhari,Mohammad Atarodi,Atefe Asadpour,Saeid Ariani,Maral |
author_role |
author |
author2 |
Eftekhari,Mohammad Atarodi,Atefe Asadpour,Saeid Ariani,Maral |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Chamsaz,Mahmoud Eftekhari,Mohammad Atarodi,Atefe Asadpour,Saeid Ariani,Maral |
dc.subject.por.fl_str_mv |
cadmium ammonium pyrroldinedithiocarbamate (APDC) ionic liquid flame atomic absorption spectrometry |
topic |
cadmium ammonium pyrroldinedithiocarbamate (APDC) ionic liquid flame atomic absorption spectrometry |
description |
A simple and rapid vortex-assisted ionic liquid based liquid-liquid microextraction (VALLME) procedure was used for the determination of trace amounts of cadmium by flame atomic absorption spectrometry (FAAS). Ionic liquid (IL), 1-hexyl-3-methylimidazolium hexafluorophosphate ([Hmim][PF]), was used as an extractant solvent. Cd2+ was complexed with ammonium pyrrolidinedithiocarbamate (APDC) and then entered into the fine IL droplets by the assistance of vortex agitator system. Some effective factors that influence the extraction efficiency such as pH, ligand concentration, amount of ionic liquid, extraction time and ionic strength effect were completely investigated and optimized. Under the optimum conditions, the limit of detection (LOD) was 1.1 ng mL-1. The relative standard deviation (RSD) was 4.3% for 20 ng mL-1 of cadmium (n = 10), and the calibration graph using the preconcentration method was linear from 5 to 150 µg L-1, with a correlation coefficient of 0.998. The proposed method was successfully applied for determination of cadmium in water samples and spinach leaves. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000900007 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000900007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532012005000026 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.23 n.9 2012 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318174069325824 |