Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction

Detalhes bibliográficos
Autor(a) principal: Pereira,Hugo B.
Data de Publicação: 2004
Outros Autores: Luna,Aderval S., Herms,Friedrich W., Campos,Reinaldo C. de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007
Resumo: A simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846.
id SBQ-2_e19561cb8cb8576b812817f18bb7b0d6
oai_identifier_str oai:scielo:S0103-50532004000400007
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correctionETAAS lead determinationNH4H2PO4 modifierbone mealA simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846.Sociedade Brasileira de Química2004-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007Journal of the Brazilian Chemical Society v.15 n.4 2004reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532004000400007info:eu-repo/semantics/openAccessPereira,Hugo B.Luna,Aderval S.Herms,Friedrich W.Campos,Reinaldo C. deeng2004-09-15T00:00:00Zoai:scielo:S0103-50532004000400007Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2004-09-15T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
title Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
spellingShingle Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
Pereira,Hugo B.
ETAAS lead determination
NH4H2PO4 modifier
bone meal
title_short Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
title_full Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
title_fullStr Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
title_full_unstemmed Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
title_sort Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
author Pereira,Hugo B.
author_facet Pereira,Hugo B.
Luna,Aderval S.
Herms,Friedrich W.
Campos,Reinaldo C. de
author_role author
author2 Luna,Aderval S.
Herms,Friedrich W.
Campos,Reinaldo C. de
author2_role author
author
author
dc.contributor.author.fl_str_mv Pereira,Hugo B.
Luna,Aderval S.
Herms,Friedrich W.
Campos,Reinaldo C. de
dc.subject.por.fl_str_mv ETAAS lead determination
NH4H2PO4 modifier
bone meal
topic ETAAS lead determination
NH4H2PO4 modifier
bone meal
description A simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846.
publishDate 2004
dc.date.none.fl_str_mv 2004-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532004000400007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.15 n.4 2004
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318165756215296