Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007 |
Resumo: | A simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846. |
id |
SBQ-2_e19561cb8cb8576b812817f18bb7b0d6 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532004000400007 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correctionETAAS lead determinationNH4H2PO4 modifierbone mealA simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846.Sociedade Brasileira de Química2004-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007Journal of the Brazilian Chemical Society v.15 n.4 2004reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532004000400007info:eu-repo/semantics/openAccessPereira,Hugo B.Luna,Aderval S.Herms,Friedrich W.Campos,Reinaldo C. deeng2004-09-15T00:00:00Zoai:scielo:S0103-50532004000400007Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2004-09-15T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction |
title |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction |
spellingShingle |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction Pereira,Hugo B. ETAAS lead determination NH4H2PO4 modifier bone meal |
title_short |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction |
title_full |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction |
title_fullStr |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction |
title_full_unstemmed |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction |
title_sort |
Determination of lead in bone by electrothermal atomic absorption spectrometry with Zeeman effect background correction |
author |
Pereira,Hugo B. |
author_facet |
Pereira,Hugo B. Luna,Aderval S. Herms,Friedrich W. Campos,Reinaldo C. de |
author_role |
author |
author2 |
Luna,Aderval S. Herms,Friedrich W. Campos,Reinaldo C. de |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Pereira,Hugo B. Luna,Aderval S. Herms,Friedrich W. Campos,Reinaldo C. de |
dc.subject.por.fl_str_mv |
ETAAS lead determination NH4H2PO4 modifier bone meal |
topic |
ETAAS lead determination NH4H2PO4 modifier bone meal |
description |
A simple method for measuring trace levels of Pb in bone by electrothermal atomic absorption spectrometry is described. It is shown that Pb can be accurately measured with good precision and accuracy using external calibration with aqueous Pb analytical solutions containing NH4H2PO4 as modifier. The detection limit was found to be 0.07 ng mL-1, corresponding to 0.022 mg g-1 in the original sample. Consequently, the limit of quantification was found to be 0.23 ng mL-1. The precision of the procedure, expressed by the relative standard deviation, was 3.5% for 400 ng Pb in sample measurements. The accuracy of the procedure was confirmed by the good concordance between found and certified values in the analysis of a bone meal certified reference material, NIST SRM 1846. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532004000400007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532004000400007 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.15 n.4 2004 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318165756215296 |