Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group

Detalhes bibliográficos
Autor(a) principal: Jesus,Dosil P. de
Data de Publicação: 2001
Outros Autores: Neves,Carlos A., Lago,Claudimir L. do
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532001000100017
Resumo: An electrode-separated piezoelectric quartz crystal sensor with a chemically modified surface was proposed. The modification was carried out by a silanization procedure with N-2-aminoethyl-3-aminopropyltrimethoxysilane, yielding the immobilised N-2-aminoethyl-3-aminopropylsilane group over the surface of a 3.5 MHz piezoelectric quartz crystal. A flow cell was manufactured with poly(methyl methacrylate) and brass, instead of noble metals, for the electrodes. In this cell, the solution touches only one side of the crystal and the related electrode is coated with a polyester film, which prevents corrosion and does not disturb the oscillation process. This innovation reduces the cost of the cell and renders an electronics non DCcoupled to the solution. The modified crystal proved to be more sensitive to copper(II) ions than magnesium(II), nickel(II), zinc(II), and cobalt(II). For 100muL sample injections, the limit of detection for copper(II) was 6 mumol L-1, which is an impressive result when compared with that for an unmodified crystal.
id SBQ-2_e72f5ac7925ac0ad69ab9922f4d1697e
oai_identifier_str oai:scielo:S0103-50532001000100017
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane groupelectrode-separated piezoelectric sensorsilanizationflow injection analysisQCMN-2-aminoethyl-3-aminopropyltrimethoxysilaneAn electrode-separated piezoelectric quartz crystal sensor with a chemically modified surface was proposed. The modification was carried out by a silanization procedure with N-2-aminoethyl-3-aminopropyltrimethoxysilane, yielding the immobilised N-2-aminoethyl-3-aminopropylsilane group over the surface of a 3.5 MHz piezoelectric quartz crystal. A flow cell was manufactured with poly(methyl methacrylate) and brass, instead of noble metals, for the electrodes. In this cell, the solution touches only one side of the crystal and the related electrode is coated with a polyester film, which prevents corrosion and does not disturb the oscillation process. This innovation reduces the cost of the cell and renders an electronics non DCcoupled to the solution. The modified crystal proved to be more sensitive to copper(II) ions than magnesium(II), nickel(II), zinc(II), and cobalt(II). For 100muL sample injections, the limit of detection for copper(II) was 6 mumol L-1, which is an impressive result when compared with that for an unmodified crystal.Sociedade Brasileira de Química2001-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532001000100017Journal of the Brazilian Chemical Society v.12 n.1 2001reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532001000100017info:eu-repo/semantics/openAccessJesus,Dosil P. deNeves,Carlos A.Lago,Claudimir L. doeng2001-04-19T00:00:00Zoai:scielo:S0103-50532001000100017Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2001-04-19T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
title Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
spellingShingle Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
Jesus,Dosil P. de
electrode-separated piezoelectric sensor
silanization
flow injection analysis
QCM
N-2-aminoethyl-3-aminopropyltrimethoxysilane
title_short Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
title_full Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
title_fullStr Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
title_full_unstemmed Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
title_sort Improving the sensitivity of electrode-separated piezoelectric quartz crystal sensor for copper(II) ions by immobilization of the N-2-aminoethyl-3-aminopropylsilane group
author Jesus,Dosil P. de
author_facet Jesus,Dosil P. de
Neves,Carlos A.
Lago,Claudimir L. do
author_role author
author2 Neves,Carlos A.
Lago,Claudimir L. do
author2_role author
author
dc.contributor.author.fl_str_mv Jesus,Dosil P. de
Neves,Carlos A.
Lago,Claudimir L. do
dc.subject.por.fl_str_mv electrode-separated piezoelectric sensor
silanization
flow injection analysis
QCM
N-2-aminoethyl-3-aminopropyltrimethoxysilane
topic electrode-separated piezoelectric sensor
silanization
flow injection analysis
QCM
N-2-aminoethyl-3-aminopropyltrimethoxysilane
description An electrode-separated piezoelectric quartz crystal sensor with a chemically modified surface was proposed. The modification was carried out by a silanization procedure with N-2-aminoethyl-3-aminopropyltrimethoxysilane, yielding the immobilised N-2-aminoethyl-3-aminopropylsilane group over the surface of a 3.5 MHz piezoelectric quartz crystal. A flow cell was manufactured with poly(methyl methacrylate) and brass, instead of noble metals, for the electrodes. In this cell, the solution touches only one side of the crystal and the related electrode is coated with a polyester film, which prevents corrosion and does not disturb the oscillation process. This innovation reduces the cost of the cell and renders an electronics non DCcoupled to the solution. The modified crystal proved to be more sensitive to copper(II) ions than magnesium(II), nickel(II), zinc(II), and cobalt(II). For 100muL sample injections, the limit of detection for copper(II) was 6 mumol L-1, which is an impressive result when compared with that for an unmodified crystal.
publishDate 2001
dc.date.none.fl_str_mv 2001-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532001000100017
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532001000100017
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532001000100017
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.12 n.1 2001
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318164217954304