Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor

Detalhes bibliográficos
Autor(a) principal: Silva,Gesiara F.
Data de Publicação: 2018
Outros Autores: Galuch,Marília B., Martins,Alessandro F., Prado,Danielle G. O., Visentainer,Jesuí V., Bonafé,Elton G.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018000901973
Resumo: The Mehlich-1 extractor is routinely used to evaluate the bioavailability of metals in soil since it has a high closeness between the amount of these elements absorbed by the plants and those available in soil, as well as being simple and practical to use. Thus, the aim of this work was to improve (optimize) a Mehlich-1 extraction method for evaluating the availability of Cu, Zn, Mn, Ni, Cr and Cd in soil using Box-Behnken type response surface method (RSM). After optimizing the soil amount, Mehlich-1 extractor volume and stirring time, the validation of the newly developed method was performed by evaluating the following parameters: matrix adjustment, linearity, linear range, limits of detection (LOD) and of quantification (LOQ), precision and accuracy. The analytical method proposed by this study can be routinely employed for the evaluation of soil toxicity since it presented advantages such as simplicity, speed and efficacy, as well as being precise and accurate.
id SBQ-2_e80c0958926318339a43d555e7d48e8f
oai_identifier_str oai:scielo:S0103-50532018000901973
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractormetalsresponse surface methodologyBox-Behnkenanalytical methodsoilThe Mehlich-1 extractor is routinely used to evaluate the bioavailability of metals in soil since it has a high closeness between the amount of these elements absorbed by the plants and those available in soil, as well as being simple and practical to use. Thus, the aim of this work was to improve (optimize) a Mehlich-1 extraction method for evaluating the availability of Cu, Zn, Mn, Ni, Cr and Cd in soil using Box-Behnken type response surface method (RSM). After optimizing the soil amount, Mehlich-1 extractor volume and stirring time, the validation of the newly developed method was performed by evaluating the following parameters: matrix adjustment, linearity, linear range, limits of detection (LOD) and of quantification (LOQ), precision and accuracy. The analytical method proposed by this study can be routinely employed for the evaluation of soil toxicity since it presented advantages such as simplicity, speed and efficacy, as well as being precise and accurate.Sociedade Brasileira de Química2018-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018000901973Journal of the Brazilian Chemical Society v.29 n.9 2018reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0103-5053.20180075info:eu-repo/semantics/openAccessSilva,Gesiara F.Galuch,Marília B.Martins,Alessandro F.Prado,Danielle G. O.Visentainer,Jesuí V.Bonafé,Elton G.eng2018-08-16T00:00:00Zoai:scielo:S0103-50532018000901973Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2018-08-16T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
title Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
spellingShingle Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
Silva,Gesiara F.
metals
response surface methodology
Box-Behnken
analytical method
soil
title_short Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
title_full Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
title_fullStr Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
title_full_unstemmed Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
title_sort Optimization and Validation of an Extraction Method for Evaluating the Availability of Cu, Zn, Mn, Ni, Cr and Cd in Soil with the Use of the Mehlich-1 Extractor
author Silva,Gesiara F.
author_facet Silva,Gesiara F.
Galuch,Marília B.
Martins,Alessandro F.
Prado,Danielle G. O.
Visentainer,Jesuí V.
Bonafé,Elton G.
author_role author
author2 Galuch,Marília B.
Martins,Alessandro F.
Prado,Danielle G. O.
Visentainer,Jesuí V.
Bonafé,Elton G.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Silva,Gesiara F.
Galuch,Marília B.
Martins,Alessandro F.
Prado,Danielle G. O.
Visentainer,Jesuí V.
Bonafé,Elton G.
dc.subject.por.fl_str_mv metals
response surface methodology
Box-Behnken
analytical method
soil
topic metals
response surface methodology
Box-Behnken
analytical method
soil
description The Mehlich-1 extractor is routinely used to evaluate the bioavailability of metals in soil since it has a high closeness between the amount of these elements absorbed by the plants and those available in soil, as well as being simple and practical to use. Thus, the aim of this work was to improve (optimize) a Mehlich-1 extraction method for evaluating the availability of Cu, Zn, Mn, Ni, Cr and Cd in soil using Box-Behnken type response surface method (RSM). After optimizing the soil amount, Mehlich-1 extractor volume and stirring time, the validation of the newly developed method was performed by evaluating the following parameters: matrix adjustment, linearity, linear range, limits of detection (LOD) and of quantification (LOQ), precision and accuracy. The analytical method proposed by this study can be routinely employed for the evaluation of soil toxicity since it presented advantages such as simplicity, speed and efficacy, as well as being precise and accurate.
publishDate 2018
dc.date.none.fl_str_mv 2018-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018000901973
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532018000901973
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.21577/0103-5053.20180075
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.29 n.9 2018
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318181197545472