Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water

Detalhes bibliográficos
Autor(a) principal: Rezemini,Andrea L.
Data de Publicação: 2008
Outros Autores: Vaz,Jorge M., Carvalho,Lilian R. F.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000500017
Resumo: Solid-phase microextraction, using on-line bis(trimethylsilyl)trifluoroacetamide derivatisation, gas chromatography, and mass spectrometry, was evaluated in the quantification of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in water samples. Fibres encompassing a wide range of polarities were used with headspace and direct immersion sampling. For the immersion procedure, various parameters affecting MX extraction, including pH, salinity, temperature, and extraction time were evaluated. The optimised method (polyacrylate fibre; 20% Na2SO4; pH 2.0; 60 min; 20 °C) was applied for reservoir chlorinated water samples-either natural or spiked with MX (50 ng L-1 and 100 ng L-1). The recovery of MX ranged from 44 to 72%. Quantification of MX in water samples was done using external standard and the selected ion monitoring mode. Correlation coefficient (0.98%), relative standard deviation (5%), limit of detection (30 ng L-1) and limit of quantification (50 ng L-1) were obtained from calibration curve.
id SBQ-2_eb977a1c5ee65dbefb8af0d92700294f
oai_identifier_str oai:scielo:S0103-50532008000500017
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in waterwater analysis3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone (MX)solid-phase microextractionGC-MSSolid-phase microextraction, using on-line bis(trimethylsilyl)trifluoroacetamide derivatisation, gas chromatography, and mass spectrometry, was evaluated in the quantification of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in water samples. Fibres encompassing a wide range of polarities were used with headspace and direct immersion sampling. For the immersion procedure, various parameters affecting MX extraction, including pH, salinity, temperature, and extraction time were evaluated. The optimised method (polyacrylate fibre; 20% Na2SO4; pH 2.0; 60 min; 20 °C) was applied for reservoir chlorinated water samples-either natural or spiked with MX (50 ng L-1 and 100 ng L-1). The recovery of MX ranged from 44 to 72%. Quantification of MX in water samples was done using external standard and the selected ion monitoring mode. Correlation coefficient (0.98%), relative standard deviation (5%), limit of detection (30 ng L-1) and limit of quantification (50 ng L-1) were obtained from calibration curve.Sociedade Brasileira de Química2008-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000500017Journal of the Brazilian Chemical Society v.19 n.5 2008reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532008000500017info:eu-repo/semantics/openAccessRezemini,Andrea L.Vaz,Jorge M.Carvalho,Lilian R. F.eng2008-08-05T00:00:00Zoai:scielo:S0103-50532008000500017Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2008-08-05T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
title Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
spellingShingle Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
Rezemini,Andrea L.
water analysis
3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone (MX)
solid-phase microextraction
GC-MS
title_short Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
title_full Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
title_fullStr Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
title_full_unstemmed Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
title_sort Solid-phase microextraction for determination of 3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone in water
author Rezemini,Andrea L.
author_facet Rezemini,Andrea L.
Vaz,Jorge M.
Carvalho,Lilian R. F.
author_role author
author2 Vaz,Jorge M.
Carvalho,Lilian R. F.
author2_role author
author
dc.contributor.author.fl_str_mv Rezemini,Andrea L.
Vaz,Jorge M.
Carvalho,Lilian R. F.
dc.subject.por.fl_str_mv water analysis
3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone (MX)
solid-phase microextraction
GC-MS
topic water analysis
3-chloro-4-(dichloromethyl)-5-hydroxy-2[5H]-furanone (MX)
solid-phase microextraction
GC-MS
description Solid-phase microextraction, using on-line bis(trimethylsilyl)trifluoroacetamide derivatisation, gas chromatography, and mass spectrometry, was evaluated in the quantification of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in water samples. Fibres encompassing a wide range of polarities were used with headspace and direct immersion sampling. For the immersion procedure, various parameters affecting MX extraction, including pH, salinity, temperature, and extraction time were evaluated. The optimised method (polyacrylate fibre; 20% Na2SO4; pH 2.0; 60 min; 20 °C) was applied for reservoir chlorinated water samples-either natural or spiked with MX (50 ng L-1 and 100 ng L-1). The recovery of MX ranged from 44 to 72%. Quantification of MX in water samples was done using external standard and the selected ion monitoring mode. Correlation coefficient (0.98%), relative standard deviation (5%), limit of detection (30 ng L-1) and limit of quantification (50 ng L-1) were obtained from calibration curve.
publishDate 2008
dc.date.none.fl_str_mv 2008-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000500017
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532008000500017
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532008000500017
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.19 n.5 2008
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318169007849472