Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS

Detalhes bibliográficos
Autor(a) principal: Pessoa,Helen M.
Data de Publicação: 2012
Outros Autores: Lyra,Fernanda H., Castro,Eustáquio Vinicius R. de, Campos,Reinaldo C. de, Carneiro,Maria Tereza W. D., Brandão,Geisamanda P.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003
Resumo: In the present study three pre-treatment procedures were developed and compared following Cr determination by GF AAS: sample dilution with toluene, emulsion formation and direct sampling of crude oil. The limits of detection for the developed procedures were 1.9 ng g-1 for sample dilution with toluene, 2.8 ng g-1 for emulsion formation and 0.73 ng g-1 for direct sampling. The accuracy of the three procedures was assessed by analysis of NIST1085b and recovery tests. High recoveries and good agreement between found and certified values were obtained in all cases. However, results indicate that sample dilution with toluene is not recommended for samples below 15ºAPI. The other two procedures showed the same performance for the samples with different API degrees (8 to 38), but the direct sampling showed better sensitivity besides minimizing the chances of analyte losses or contamination.
id SBQ-2_ec87886752ed404876c15b233a06c1f5
oai_identifier_str oai:scielo:S0103-50532012000800003
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AASCrcrude oilsample pre-treatment proceduresGF AASIn the present study three pre-treatment procedures were developed and compared following Cr determination by GF AAS: sample dilution with toluene, emulsion formation and direct sampling of crude oil. The limits of detection for the developed procedures were 1.9 ng g-1 for sample dilution with toluene, 2.8 ng g-1 for emulsion formation and 0.73 ng g-1 for direct sampling. The accuracy of the three procedures was assessed by analysis of NIST1085b and recovery tests. High recoveries and good agreement between found and certified values were obtained in all cases. However, results indicate that sample dilution with toluene is not recommended for samples below 15ºAPI. The other two procedures showed the same performance for the samples with different API degrees (8 to 38), but the direct sampling showed better sensitivity besides minimizing the chances of analyte losses or contamination.Sociedade Brasileira de Química2012-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003Journal of the Brazilian Chemical Society v.23 n.8 2012reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532012005000004info:eu-repo/semantics/openAccessPessoa,Helen M.Lyra,Fernanda H.Castro,Eustáquio Vinicius R. deCampos,Reinaldo C. deCarneiro,Maria Tereza W. D.Brandão,Geisamanda P.eng2012-09-17T00:00:00Zoai:scielo:S0103-50532012000800003Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2012-09-17T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
title Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
spellingShingle Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
Pessoa,Helen M.
Cr
crude oil
sample pre-treatment procedures
GF AAS
title_short Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
title_full Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
title_fullStr Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
title_full_unstemmed Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
title_sort Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
author Pessoa,Helen M.
author_facet Pessoa,Helen M.
Lyra,Fernanda H.
Castro,Eustáquio Vinicius R. de
Campos,Reinaldo C. de
Carneiro,Maria Tereza W. D.
Brandão,Geisamanda P.
author_role author
author2 Lyra,Fernanda H.
Castro,Eustáquio Vinicius R. de
Campos,Reinaldo C. de
Carneiro,Maria Tereza W. D.
Brandão,Geisamanda P.
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Pessoa,Helen M.
Lyra,Fernanda H.
Castro,Eustáquio Vinicius R. de
Campos,Reinaldo C. de
Carneiro,Maria Tereza W. D.
Brandão,Geisamanda P.
dc.subject.por.fl_str_mv Cr
crude oil
sample pre-treatment procedures
GF AAS
topic Cr
crude oil
sample pre-treatment procedures
GF AAS
description In the present study three pre-treatment procedures were developed and compared following Cr determination by GF AAS: sample dilution with toluene, emulsion formation and direct sampling of crude oil. The limits of detection for the developed procedures were 1.9 ng g-1 for sample dilution with toluene, 2.8 ng g-1 for emulsion formation and 0.73 ng g-1 for direct sampling. The accuracy of the three procedures was assessed by analysis of NIST1085b and recovery tests. High recoveries and good agreement between found and certified values were obtained in all cases. However, results indicate that sample dilution with toluene is not recommended for samples below 15ºAPI. The other two procedures showed the same performance for the samples with different API degrees (8 to 38), but the direct sampling showed better sensitivity besides minimizing the chances of analyte losses or contamination.
publishDate 2012
dc.date.none.fl_str_mv 2012-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532012005000004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.23 n.8 2012
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318174035771392