Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Journal of the Brazilian Chemical Society (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003 |
Resumo: | In the present study three pre-treatment procedures were developed and compared following Cr determination by GF AAS: sample dilution with toluene, emulsion formation and direct sampling of crude oil. The limits of detection for the developed procedures were 1.9 ng g-1 for sample dilution with toluene, 2.8 ng g-1 for emulsion formation and 0.73 ng g-1 for direct sampling. The accuracy of the three procedures was assessed by analysis of NIST1085b and recovery tests. High recoveries and good agreement between found and certified values were obtained in all cases. However, results indicate that sample dilution with toluene is not recommended for samples below 15ºAPI. The other two procedures showed the same performance for the samples with different API degrees (8 to 38), but the direct sampling showed better sensitivity besides minimizing the chances of analyte losses or contamination. |
id |
SBQ-2_ec87886752ed404876c15b233a06c1f5 |
---|---|
oai_identifier_str |
oai:scielo:S0103-50532012000800003 |
network_acronym_str |
SBQ-2 |
network_name_str |
Journal of the Brazilian Chemical Society (Online) |
repository_id_str |
|
spelling |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AASCrcrude oilsample pre-treatment proceduresGF AASIn the present study three pre-treatment procedures were developed and compared following Cr determination by GF AAS: sample dilution with toluene, emulsion formation and direct sampling of crude oil. The limits of detection for the developed procedures were 1.9 ng g-1 for sample dilution with toluene, 2.8 ng g-1 for emulsion formation and 0.73 ng g-1 for direct sampling. The accuracy of the three procedures was assessed by analysis of NIST1085b and recovery tests. High recoveries and good agreement between found and certified values were obtained in all cases. However, results indicate that sample dilution with toluene is not recommended for samples below 15ºAPI. The other two procedures showed the same performance for the samples with different API degrees (8 to 38), but the direct sampling showed better sensitivity besides minimizing the chances of analyte losses or contamination.Sociedade Brasileira de Química2012-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003Journal of the Brazilian Chemical Society v.23 n.8 2012reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532012005000004info:eu-repo/semantics/openAccessPessoa,Helen M.Lyra,Fernanda H.Castro,Eustáquio Vinicius R. deCampos,Reinaldo C. deCarneiro,Maria Tereza W. D.Brandão,Geisamanda P.eng2012-09-17T00:00:00Zoai:scielo:S0103-50532012000800003Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2012-09-17T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS |
title |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS |
spellingShingle |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS Pessoa,Helen M. Cr crude oil sample pre-treatment procedures GF AAS |
title_short |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS |
title_full |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS |
title_fullStr |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS |
title_full_unstemmed |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS |
title_sort |
Comparison of different pre-treatment procedures for the determination of chromium in crude oil samples by GF AAS |
author |
Pessoa,Helen M. |
author_facet |
Pessoa,Helen M. Lyra,Fernanda H. Castro,Eustáquio Vinicius R. de Campos,Reinaldo C. de Carneiro,Maria Tereza W. D. Brandão,Geisamanda P. |
author_role |
author |
author2 |
Lyra,Fernanda H. Castro,Eustáquio Vinicius R. de Campos,Reinaldo C. de Carneiro,Maria Tereza W. D. Brandão,Geisamanda P. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Pessoa,Helen M. Lyra,Fernanda H. Castro,Eustáquio Vinicius R. de Campos,Reinaldo C. de Carneiro,Maria Tereza W. D. Brandão,Geisamanda P. |
dc.subject.por.fl_str_mv |
Cr crude oil sample pre-treatment procedures GF AAS |
topic |
Cr crude oil sample pre-treatment procedures GF AAS |
description |
In the present study three pre-treatment procedures were developed and compared following Cr determination by GF AAS: sample dilution with toluene, emulsion formation and direct sampling of crude oil. The limits of detection for the developed procedures were 1.9 ng g-1 for sample dilution with toluene, 2.8 ng g-1 for emulsion formation and 0.73 ng g-1 for direct sampling. The accuracy of the three procedures was assessed by analysis of NIST1085b and recovery tests. High recoveries and good agreement between found and certified values were obtained in all cases. However, results indicate that sample dilution with toluene is not recommended for samples below 15ºAPI. The other two procedures showed the same performance for the samples with different API degrees (8 to 38), but the direct sampling showed better sensitivity besides minimizing the chances of analyte losses or contamination. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000800003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0103-50532012005000004 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Journal of the Brazilian Chemical Society v.23 n.8 2012 reponame:Journal of the Brazilian Chemical Society (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Journal of the Brazilian Chemical Society (Online) |
collection |
Journal of the Brazilian Chemical Society (Online) |
repository.name.fl_str_mv |
Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
||office@jbcs.sbq.org.br |
_version_ |
1750318174035771392 |