Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis

Detalhes bibliográficos
Autor(a) principal: Oliveira,Elcio Cruz de
Data de Publicação: 2010
Outros Autores: Muller,Edson I., Abad,Fernanda, Dallarosa,Juliana, Adriano,Cristine
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Química Nova (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000400041
Resumo: Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.
id SBQ-3_0ae1c811ac978d93ad9338c6e4143adb
oai_identifier_str oai:scielo:S0100-40422010000400041
network_acronym_str SBQ-3
network_name_str Química Nova (Online)
repository_id_str
spelling Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysisinternal and external standard calibrationmeasurement uncertaintybias correction factorTraditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.Sociedade Brasileira de Química2010-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000400041Química Nova v.33 n.4 2010reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422010000400041info:eu-repo/semantics/openAccessOliveira,Elcio Cruz deMuller,Edson I.Abad,FernandaDallarosa,JulianaAdriano,Cristineeng2010-06-02T00:00:00Zoai:scielo:S0100-40422010000400041Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2010-06-02T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
title Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
spellingShingle Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
Oliveira,Elcio Cruz de
internal and external standard calibration
measurement uncertainty
bias correction factor
title_short Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
title_full Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
title_fullStr Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
title_full_unstemmed Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
title_sort Internal standard versus external standard calibration: an uncertainty case study of a liquid chromatography analysis
author Oliveira,Elcio Cruz de
author_facet Oliveira,Elcio Cruz de
Muller,Edson I.
Abad,Fernanda
Dallarosa,Juliana
Adriano,Cristine
author_role author
author2 Muller,Edson I.
Abad,Fernanda
Dallarosa,Juliana
Adriano,Cristine
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Oliveira,Elcio Cruz de
Muller,Edson I.
Abad,Fernanda
Dallarosa,Juliana
Adriano,Cristine
dc.subject.por.fl_str_mv internal and external standard calibration
measurement uncertainty
bias correction factor
topic internal and external standard calibration
measurement uncertainty
bias correction factor
description Traditionally, in the cigarettes industry, the determination of ammonium ion in the mainstream smoke is performed by ion chromatography. This work studies this determination and compares the results of this technique with the use of external and internal standard calibration. A reference cigarette sample presented measurement uncertainty of 2.0 μg/cigarette and 1.5 μg/cigarette, with external and internal standard, respectively. It is observed that the greatest source of uncertainty is the bias correction factor and that it is even more significant when using external standard, confirming thus the importance of internal standardization for this correction.
publishDate 2010
dc.date.none.fl_str_mv 2010-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000400041
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000400041
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-40422010000400041
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Química Nova v.33 n.4 2010
reponame:Química Nova (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Química Nova (Online)
collection Química Nova (Online)
repository.name.fl_str_mv Química Nova (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv quimicanova@sbq.org.br
_version_ 1750318110705975296