A screening method for detection of hexavalent chromium levels in soils

Detalhes bibliográficos
Autor(a) principal: Franco,Débora V
Data de Publicação: 2011
Outros Autores: Rodrigues,Maria Lucia Kolowski, Bavaresco,Jovana, Jardim,Wilson F
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Química Nova (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000700025
Resumo: A rapid and low cost method to determine Cr(VI) in soils based upon alkaline metal extraction at room temperature is proposed as a semi-quantitative procedure to be performed in the field. A color comparison with standards with contents of Cr(VI) in the range of 10 to 150 mg kg-1 was used throughout. For the different types of soils studied, more than 75% of the fortified soluble Cr(VI) were recovered for all levels of spike tested for both the proposed and standard methods. Recoveries of 83 and 99% were obtained for the proposed and the standard methods, respectively, taking into account the analysis of a heavily contaminated soil sample.
id SBQ-3_6ab85e8fd33af3ef578907ef1e5eb3d3
oai_identifier_str oai:scielo:S0100-40422011000700025
network_acronym_str SBQ-3
network_name_str Química Nova (Online)
repository_id_str
spelling A screening method for detection of hexavalent chromium levels in soilshexavalent chromiumscreening methodssoilA rapid and low cost method to determine Cr(VI) in soils based upon alkaline metal extraction at room temperature is proposed as a semi-quantitative procedure to be performed in the field. A color comparison with standards with contents of Cr(VI) in the range of 10 to 150 mg kg-1 was used throughout. For the different types of soils studied, more than 75% of the fortified soluble Cr(VI) were recovered for all levels of spike tested for both the proposed and standard methods. Recoveries of 83 and 99% were obtained for the proposed and the standard methods, respectively, taking into account the analysis of a heavily contaminated soil sample.Sociedade Brasileira de Química2011-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000700025Química Nova v.34 n.7 2011reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422011000700025info:eu-repo/semantics/openAccessFranco,Débora VRodrigues,Maria Lucia KolowskiBavaresco,JovanaJardim,Wilson Feng2011-09-12T00:00:00Zoai:scielo:S0100-40422011000700025Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2011-09-12T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv A screening method for detection of hexavalent chromium levels in soils
title A screening method for detection of hexavalent chromium levels in soils
spellingShingle A screening method for detection of hexavalent chromium levels in soils
Franco,Débora V
hexavalent chromium
screening methods
soil
title_short A screening method for detection of hexavalent chromium levels in soils
title_full A screening method for detection of hexavalent chromium levels in soils
title_fullStr A screening method for detection of hexavalent chromium levels in soils
title_full_unstemmed A screening method for detection of hexavalent chromium levels in soils
title_sort A screening method for detection of hexavalent chromium levels in soils
author Franco,Débora V
author_facet Franco,Débora V
Rodrigues,Maria Lucia Kolowski
Bavaresco,Jovana
Jardim,Wilson F
author_role author
author2 Rodrigues,Maria Lucia Kolowski
Bavaresco,Jovana
Jardim,Wilson F
author2_role author
author
author
dc.contributor.author.fl_str_mv Franco,Débora V
Rodrigues,Maria Lucia Kolowski
Bavaresco,Jovana
Jardim,Wilson F
dc.subject.por.fl_str_mv hexavalent chromium
screening methods
soil
topic hexavalent chromium
screening methods
soil
description A rapid and low cost method to determine Cr(VI) in soils based upon alkaline metal extraction at room temperature is proposed as a semi-quantitative procedure to be performed in the field. A color comparison with standards with contents of Cr(VI) in the range of 10 to 150 mg kg-1 was used throughout. For the different types of soils studied, more than 75% of the fortified soluble Cr(VI) were recovered for all levels of spike tested for both the proposed and standard methods. Recoveries of 83 and 99% were obtained for the proposed and the standard methods, respectively, taking into account the analysis of a heavily contaminated soil sample.
publishDate 2011
dc.date.none.fl_str_mv 2011-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000700025
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000700025
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-40422011000700025
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Química Nova v.34 n.7 2011
reponame:Química Nova (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Química Nova (Online)
collection Química Nova (Online)
repository.name.fl_str_mv Química Nova (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv quimicanova@sbq.org.br
_version_ 1750318112371113984