VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015000300419 |
Resumo: | 17α-methyltestosterone (17α-MT) is a hormone used in medicine and aquaculture which can be found in natural waters. It is considered an emerging organic pollutant and its accurate and precise analysis is required. Therefore, this study presents the in-house validation of a new voltammetric methodology for 17α-MT analysis in natural waters. A hanging mercury drop electrode and NaOH 5.0×10-3 mol L-1 solution as the electrolyte were employed in the voltammetric determinations. To confirm the presence of 17α-MT in water samples quantitative analysis was performed by ESI-MS/MS. The methodology exhibited good selectivity, linearity, accuracy (recovery of between 100.4 and 108.8%) and precision (RSDs for repeatability of 2.85% and for intermediate precision of 14.10%, with n = 5, respectively). LOD and LOQ were 3.07 µg L-1 and 10.78 µg L-1, respectively. The methodology was suitable for determination of 17α-MT in natural waters due to low-cost, good performance and no sample pre-treatment required. |
id |
SBQ-3_7e22954c11fe8765650c08db3506a393 |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422015000300419 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO17α-methyltestosteronenatural watersvoltammetrymethod validation17α-methyltestosterone (17α-MT) is a hormone used in medicine and aquaculture which can be found in natural waters. It is considered an emerging organic pollutant and its accurate and precise analysis is required. Therefore, this study presents the in-house validation of a new voltammetric methodology for 17α-MT analysis in natural waters. A hanging mercury drop electrode and NaOH 5.0×10-3 mol L-1 solution as the electrolyte were employed in the voltammetric determinations. To confirm the presence of 17α-MT in water samples quantitative analysis was performed by ESI-MS/MS. The methodology exhibited good selectivity, linearity, accuracy (recovery of between 100.4 and 108.8%) and precision (RSDs for repeatability of 2.85% and for intermediate precision of 14.10%, with n = 5, respectively). LOD and LOQ were 3.07 µg L-1 and 10.78 µg L-1, respectively. The methodology was suitable for determination of 17α-MT in natural waters due to low-cost, good performance and no sample pre-treatment required.Sociedade Brasileira de Química2015-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015000300419Química Nova v.38 n.3 2015reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0100-4042.20150014info:eu-repo/semantics/openAccessMiranda,LucianeFelsner,Maria L.Torres,Yohandra R.Hoss,IvoneteGalli,AndressaQuináia,Sueli P.por2015-05-12T00:00:00Zoai:scielo:S0100-40422015000300419Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2015-05-12T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO |
title |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO |
spellingShingle |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO Miranda,Luciane 17α-methyltestosterone natural waters voltammetry method validation |
title_short |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO |
title_full |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO |
title_fullStr |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO |
title_full_unstemmed |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO |
title_sort |
VALIDAÇÃO INTRALABORATORIAL DA DETERMINAÇÃO DE METILTESTOSTERONA EM ÁGUAS NATURAIS POR VOLTAMETRIA USANDO ELETRODO DE GOTA PENDENTE DE MERCÚRIO |
author |
Miranda,Luciane |
author_facet |
Miranda,Luciane Felsner,Maria L. Torres,Yohandra R. Hoss,Ivonete Galli,Andressa Quináia,Sueli P. |
author_role |
author |
author2 |
Felsner,Maria L. Torres,Yohandra R. Hoss,Ivonete Galli,Andressa Quináia,Sueli P. |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Miranda,Luciane Felsner,Maria L. Torres,Yohandra R. Hoss,Ivonete Galli,Andressa Quináia,Sueli P. |
dc.subject.por.fl_str_mv |
17α-methyltestosterone natural waters voltammetry method validation |
topic |
17α-methyltestosterone natural waters voltammetry method validation |
description |
17α-methyltestosterone (17α-MT) is a hormone used in medicine and aquaculture which can be found in natural waters. It is considered an emerging organic pollutant and its accurate and precise analysis is required. Therefore, this study presents the in-house validation of a new voltammetric methodology for 17α-MT analysis in natural waters. A hanging mercury drop electrode and NaOH 5.0×10-3 mol L-1 solution as the electrolyte were employed in the voltammetric determinations. To confirm the presence of 17α-MT in water samples quantitative analysis was performed by ESI-MS/MS. The methodology exhibited good selectivity, linearity, accuracy (recovery of between 100.4 and 108.8%) and precision (RSDs for repeatability of 2.85% and for intermediate precision of 14.10%, with n = 5, respectively). LOD and LOQ were 3.07 µg L-1 and 10.78 µg L-1, respectively. The methodology was suitable for determination of 17α-MT in natural waters due to low-cost, good performance and no sample pre-treatment required. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015000300419 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015000300419 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
10.5935/0100-4042.20150014 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.38 n.3 2015 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318116688101376 |