DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015001001339 |
Resumo: | Ultrasound as a metrology tool has many applications in health care, industrial, and chemical analyses. Ultrasonic techniques are rapid, low-cost, non-invasive, and highly repeatable. Although ultrasound can be used to measure emulsions, no effort had been made thus far to optimize its sensitivity for metrological analysis. In this work, a technique for analyzing oil in water was validated. The wave velocity and attenuation were chosen as the ultrasonic parameters. The technique was implemented in the boundary region established by law for effluents from industrial plants involved with biofuel manufacturing. A technical effort of this study was to establish stable emulsions in concentrations close to the desired limit of study. The phase behaviours of pseudo-ternary oil, sodium chloride, and sodium lauryl sulphate were studied. The composition in the widest region of the diagram allowed for the formation of a stable emulsion, from which the ultrasound measurement was carried out. An analytical curve was obtained using ultrasonic attenuation to determine the content of oils and greases in wastewater ranging 15–240 ppm. The speed of sound did not appear to be an applicable parameter for this application. The technique was demonstrated to be an important alternative solution for the continuous monitoring of wastewater with regard to oil concentrations. |
id |
SBQ-3_a7b80e7eb7bf6ef99a18876cadfe1c0e |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422015001001339 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEISultrasoundbiofuel wastewateroil-in-water emulsionmetrologyUltrasound as a metrology tool has many applications in health care, industrial, and chemical analyses. Ultrasonic techniques are rapid, low-cost, non-invasive, and highly repeatable. Although ultrasound can be used to measure emulsions, no effort had been made thus far to optimize its sensitivity for metrological analysis. In this work, a technique for analyzing oil in water was validated. The wave velocity and attenuation were chosen as the ultrasonic parameters. The technique was implemented in the boundary region established by law for effluents from industrial plants involved with biofuel manufacturing. A technical effort of this study was to establish stable emulsions in concentrations close to the desired limit of study. The phase behaviours of pseudo-ternary oil, sodium chloride, and sodium lauryl sulphate were studied. The composition in the widest region of the diagram allowed for the formation of a stable emulsion, from which the ultrasound measurement was carried out. An analytical curve was obtained using ultrasonic attenuation to determine the content of oils and greases in wastewater ranging 15–240 ppm. The speed of sound did not appear to be an applicable parameter for this application. The technique was demonstrated to be an important alternative solution for the continuous monitoring of wastewater with regard to oil concentrations.Sociedade Brasileira de Química2015-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015001001339Química Nova v.38 n.10 2015reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0100-4042.20150153info:eu-repo/semantics/openAccessSilva,Luciano Segné F.Bibiano,Douglas S.Figueiredo,Monique Kort-KampCosta-Félix,Rodrigo P. B.por2015-12-17T00:00:00Zoai:scielo:S0100-40422015001001339Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2015-12-17T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS |
title |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS |
spellingShingle |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS Silva,Luciano Segné F. ultrasound biofuel wastewater oil-in-water emulsion metrology |
title_short |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS |
title_full |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS |
title_fullStr |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS |
title_full_unstemmed |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS |
title_sort |
DESENVOLVIMENTO DE UMA TÉCNICA ULTRASSÔNICA PARA AVALIAR TEORES DE ÓLEO E GRAXA EM EFLUENTES DE BIOCOMBUSTÍVEIS |
author |
Silva,Luciano Segné F. |
author_facet |
Silva,Luciano Segné F. Bibiano,Douglas S. Figueiredo,Monique Kort-Kamp Costa-Félix,Rodrigo P. B. |
author_role |
author |
author2 |
Bibiano,Douglas S. Figueiredo,Monique Kort-Kamp Costa-Félix,Rodrigo P. B. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Silva,Luciano Segné F. Bibiano,Douglas S. Figueiredo,Monique Kort-Kamp Costa-Félix,Rodrigo P. B. |
dc.subject.por.fl_str_mv |
ultrasound biofuel wastewater oil-in-water emulsion metrology |
topic |
ultrasound biofuel wastewater oil-in-water emulsion metrology |
description |
Ultrasound as a metrology tool has many applications in health care, industrial, and chemical analyses. Ultrasonic techniques are rapid, low-cost, non-invasive, and highly repeatable. Although ultrasound can be used to measure emulsions, no effort had been made thus far to optimize its sensitivity for metrological analysis. In this work, a technique for analyzing oil in water was validated. The wave velocity and attenuation were chosen as the ultrasonic parameters. The technique was implemented in the boundary region established by law for effluents from industrial plants involved with biofuel manufacturing. A technical effort of this study was to establish stable emulsions in concentrations close to the desired limit of study. The phase behaviours of pseudo-ternary oil, sodium chloride, and sodium lauryl sulphate were studied. The composition in the widest region of the diagram allowed for the formation of a stable emulsion, from which the ultrasound measurement was carried out. An analytical curve was obtained using ultrasonic attenuation to determine the content of oils and greases in wastewater ranging 15–240 ppm. The speed of sound did not appear to be an applicable parameter for this application. The technique was demonstrated to be an important alternative solution for the continuous monitoring of wastewater with regard to oil concentrations. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015001001339 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422015001001339 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
10.5935/0100-4042.20150153 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.38 n.10 2015 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318117131649024 |