Determination of triamterene in human plasma and urine after its cloud point extraction
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013 |
Resumo: | A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples. |
id |
SBQ-3_b52d85e072df71d033e1f6ae6297deff |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422014000700013 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
Determination of triamterene in human plasma and urine after its cloud point extractioncloud point extractiontriamterenebiological fluidsspectrofluorimetryA new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.Sociedade Brasileira de Química2014-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013Química Nova v.37 n.7 2014reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0100-4042.20140188info:eu-repo/semantics/openAccessTabrizi,Ahad BaviliNaini,SanaParnian,KosarMohammadi,Saminzad,Fayeze EmamiAnvarian,Samira PourtaghiAbdollahi,Alieng2014-08-26T00:00:00Zoai:scielo:S0100-40422014000700013Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2014-08-26T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Determination of triamterene in human plasma and urine after its cloud point extraction |
title |
Determination of triamterene in human plasma and urine after its cloud point extraction |
spellingShingle |
Determination of triamterene in human plasma and urine after its cloud point extraction Tabrizi,Ahad Bavili cloud point extraction triamterene biological fluids spectrofluorimetry |
title_short |
Determination of triamterene in human plasma and urine after its cloud point extraction |
title_full |
Determination of triamterene in human plasma and urine after its cloud point extraction |
title_fullStr |
Determination of triamterene in human plasma and urine after its cloud point extraction |
title_full_unstemmed |
Determination of triamterene in human plasma and urine after its cloud point extraction |
title_sort |
Determination of triamterene in human plasma and urine after its cloud point extraction |
author |
Tabrizi,Ahad Bavili |
author_facet |
Tabrizi,Ahad Bavili Naini,Sana Parnian,Kosar Mohammadi,Samin zad,Fayeze Emami Anvarian,Samira Pourtaghi Abdollahi,Ali |
author_role |
author |
author2 |
Naini,Sana Parnian,Kosar Mohammadi,Samin zad,Fayeze Emami Anvarian,Samira Pourtaghi Abdollahi,Ali |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Tabrizi,Ahad Bavili Naini,Sana Parnian,Kosar Mohammadi,Samin zad,Fayeze Emami Anvarian,Samira Pourtaghi Abdollahi,Ali |
dc.subject.por.fl_str_mv |
cloud point extraction triamterene biological fluids spectrofluorimetry |
topic |
cloud point extraction triamterene biological fluids spectrofluorimetry |
description |
A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0100-4042.20140188 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.37 n.7 2014 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318115960389632 |