Determination of triamterene in human plasma and urine after its cloud point extraction

Detalhes bibliográficos
Autor(a) principal: Tabrizi,Ahad Bavili
Data de Publicação: 2014
Outros Autores: Naini,Sana, Parnian,Kosar, Mohammadi,Samin, zad,Fayeze Emami, Anvarian,Samira Pourtaghi, Abdollahi,Ali
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Química Nova (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013
Resumo: A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.
id SBQ-3_b52d85e072df71d033e1f6ae6297deff
oai_identifier_str oai:scielo:S0100-40422014000700013
network_acronym_str SBQ-3
network_name_str Química Nova (Online)
repository_id_str
spelling Determination of triamterene in human plasma and urine after its cloud point extractioncloud point extractiontriamterenebiological fluidsspectrofluorimetryA new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.Sociedade Brasileira de Química2014-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013Química Nova v.37 n.7 2014reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0100-4042.20140188info:eu-repo/semantics/openAccessTabrizi,Ahad BaviliNaini,SanaParnian,KosarMohammadi,Saminzad,Fayeze EmamiAnvarian,Samira PourtaghiAbdollahi,Alieng2014-08-26T00:00:00Zoai:scielo:S0100-40422014000700013Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2014-08-26T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Determination of triamterene in human plasma and urine after its cloud point extraction
title Determination of triamterene in human plasma and urine after its cloud point extraction
spellingShingle Determination of triamterene in human plasma and urine after its cloud point extraction
Tabrizi,Ahad Bavili
cloud point extraction
triamterene
biological fluids
spectrofluorimetry
title_short Determination of triamterene in human plasma and urine after its cloud point extraction
title_full Determination of triamterene in human plasma and urine after its cloud point extraction
title_fullStr Determination of triamterene in human plasma and urine after its cloud point extraction
title_full_unstemmed Determination of triamterene in human plasma and urine after its cloud point extraction
title_sort Determination of triamterene in human plasma and urine after its cloud point extraction
author Tabrizi,Ahad Bavili
author_facet Tabrizi,Ahad Bavili
Naini,Sana
Parnian,Kosar
Mohammadi,Samin
zad,Fayeze Emami
Anvarian,Samira Pourtaghi
Abdollahi,Ali
author_role author
author2 Naini,Sana
Parnian,Kosar
Mohammadi,Samin
zad,Fayeze Emami
Anvarian,Samira Pourtaghi
Abdollahi,Ali
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Tabrizi,Ahad Bavili
Naini,Sana
Parnian,Kosar
Mohammadi,Samin
zad,Fayeze Emami
Anvarian,Samira Pourtaghi
Abdollahi,Ali
dc.subject.por.fl_str_mv cloud point extraction
triamterene
biological fluids
spectrofluorimetry
topic cloud point extraction
triamterene
biological fluids
spectrofluorimetry
description A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.
publishDate 2014
dc.date.none.fl_str_mv 2014-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422014000700013
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0100-4042.20140188
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Química Nova v.37 n.7 2014
reponame:Química Nova (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Química Nova (Online)
collection Química Nova (Online)
repository.name.fl_str_mv Química Nova (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv quimicanova@sbq.org.br
_version_ 1750318115960389632