USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | por |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422021000100020 |
Resumo: | In this work, an alternative and low-cost technique for the extraction and quantification of Fe (total) from food supplements by digital image analysis is shown. The method is based on the complexation of Fe ions in solution with the 8-hydroxyquinoline ligand, forming a colored complex that is extractable from aqueous solution to polyurethane foam, coloring this one, which was initially white, to brown. After the acquisition and treatment of the digital image generated by the foam, the quantification of Fe is performed. Interference and recovery tests show that the method is not affected by concomitants in the sample. The method was applied to 3 different types of dietary supplements, and these results were compared to those obtained by FAAS, showing statistical equivalence. The limits of quantification obtained in this work was 1.78 µmol L-1, the limit of detection was 0.53 µmol L-1, the accuracy was 97.5 + 4.8% and the precision was 8.45%. The analytical curve was linear from 2.0 to 10.0 µmol L-1, with a r2 of 0.9975. |
id |
SBQ-3_ba0b9200471374f3ec525ed026da0336 |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422021000100020 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARESdigital image analysispolyurethane foamfood supplementsIn this work, an alternative and low-cost technique for the extraction and quantification of Fe (total) from food supplements by digital image analysis is shown. The method is based on the complexation of Fe ions in solution with the 8-hydroxyquinoline ligand, forming a colored complex that is extractable from aqueous solution to polyurethane foam, coloring this one, which was initially white, to brown. After the acquisition and treatment of the digital image generated by the foam, the quantification of Fe is performed. Interference and recovery tests show that the method is not affected by concomitants in the sample. The method was applied to 3 different types of dietary supplements, and these results were compared to those obtained by FAAS, showing statistical equivalence. The limits of quantification obtained in this work was 1.78 µmol L-1, the limit of detection was 0.53 µmol L-1, the accuracy was 97.5 + 4.8% and the precision was 8.45%. The analytical curve was linear from 2.0 to 10.0 µmol L-1, with a r2 of 0.9975.Sociedade Brasileira de Química2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422021000100020Química Nova v.44 n.1 2021reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0100-4042.20170657info:eu-repo/semantics/openAccessFeiteira,Fernanda. N.Barreiros,João V. de P. P.Pacheco,Wagner F.por2021-03-17T00:00:00Zoai:scielo:S0100-40422021000100020Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2021-03-17T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES |
title |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES |
spellingShingle |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES Feiteira,Fernanda. N. digital image analysis polyurethane foam food supplements |
title_short |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES |
title_full |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES |
title_fullStr |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES |
title_full_unstemmed |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES |
title_sort |
USO DE UM SCANNER DE MESA E ESPUMA DE POLIURETANO PARA QUANTIFICAÇÃO DE FERRO TOTAL EM CÁPSULAS DE SUPLEMENTOS ALIMENTARES |
author |
Feiteira,Fernanda. N. |
author_facet |
Feiteira,Fernanda. N. Barreiros,João V. de P. P. Pacheco,Wagner F. |
author_role |
author |
author2 |
Barreiros,João V. de P. P. Pacheco,Wagner F. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Feiteira,Fernanda. N. Barreiros,João V. de P. P. Pacheco,Wagner F. |
dc.subject.por.fl_str_mv |
digital image analysis polyurethane foam food supplements |
topic |
digital image analysis polyurethane foam food supplements |
description |
In this work, an alternative and low-cost technique for the extraction and quantification of Fe (total) from food supplements by digital image analysis is shown. The method is based on the complexation of Fe ions in solution with the 8-hydroxyquinoline ligand, forming a colored complex that is extractable from aqueous solution to polyurethane foam, coloring this one, which was initially white, to brown. After the acquisition and treatment of the digital image generated by the foam, the quantification of Fe is performed. Interference and recovery tests show that the method is not affected by concomitants in the sample. The method was applied to 3 different types of dietary supplements, and these results were compared to those obtained by FAAS, showing statistical equivalence. The limits of quantification obtained in this work was 1.78 µmol L-1, the limit of detection was 0.53 µmol L-1, the accuracy was 97.5 + 4.8% and the precision was 8.45%. The analytical curve was linear from 2.0 to 10.0 µmol L-1, with a r2 of 0.9975. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422021000100020 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422021000100020 |
dc.language.iso.fl_str_mv |
por |
language |
por |
dc.relation.none.fl_str_mv |
10.21577/0100-4042.20170657 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.44 n.1 2021 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318120995651584 |