IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS
Autor(a) principal: | |
---|---|
Data de Publicação: | 2019 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019004700729 |
Resumo: | The optimized analytical methodology described herein is based on an ion exchange column and an H3PO4 solution (pH 2.24) as the mobile phase, with a flow rate of 0.4 mL min-1 and refractive index detection (RID). On applying the methodology, it was possible to identify 7 products obtained from the oxidation of glycerol with an analysis time of 27 min. The developed method was validated through the evaluation of a series of analytical parameters. The results obtained were evaluated considering the peak area and peak height. The analytical curves showed a correlation coefficient of ≥ 0.986. The coefficient of variation values obtained were ≤ 3.60% for instrumental precision, ≤ 19.36% for intermediate precision in LOQ (1.25 µg mL-1) and ≤ 17.93% for repeatability in LOQ (1.25 µg mL-1) and different days. The limit of quantification established for all compounds was 1.25 µg mL-1 obtained through the parameters of the analytical curve. The accuracy of the method showed recovery values of 85.6 to 112.3% for real fortified sample at 3 concentration levels. Two different samples of glycerol oxidation products were applied to the validated methodology; one obtained from AuNP/SiO2 as catalyst (conversion of 62.42%), and other using AuNP/MWCNT (conversion of 89.5%). |
id |
SBQ-3_c3d9a655a30ccbfaa9bc11e6a8f1234f |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422019004700729 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTSHigh-performance Liquid Chromatographyion exchange columnglycerol oxidationanalytical methodologiesidentification and quantificationThe optimized analytical methodology described herein is based on an ion exchange column and an H3PO4 solution (pH 2.24) as the mobile phase, with a flow rate of 0.4 mL min-1 and refractive index detection (RID). On applying the methodology, it was possible to identify 7 products obtained from the oxidation of glycerol with an analysis time of 27 min. The developed method was validated through the evaluation of a series of analytical parameters. The results obtained were evaluated considering the peak area and peak height. The analytical curves showed a correlation coefficient of ≥ 0.986. The coefficient of variation values obtained were ≤ 3.60% for instrumental precision, ≤ 19.36% for intermediate precision in LOQ (1.25 µg mL-1) and ≤ 17.93% for repeatability in LOQ (1.25 µg mL-1) and different days. The limit of quantification established for all compounds was 1.25 µg mL-1 obtained through the parameters of the analytical curve. The accuracy of the method showed recovery values of 85.6 to 112.3% for real fortified sample at 3 concentration levels. Two different samples of glycerol oxidation products were applied to the validated methodology; one obtained from AuNP/SiO2 as catalyst (conversion of 62.42%), and other using AuNP/MWCNT (conversion of 89.5%).Sociedade Brasileira de Química2019-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019004700729Química Nova v.42 n.7 2019reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.21577/0100-4042.20170391info:eu-repo/semantics/openAccessGiertyas,Cristian J.Silva,Débora S. daSilva,Camila L. F. daMeneghetti,Mario R.Meneghetti,Simoni M. PlentzAlmeida,Rusiene M. deBortoluzzi,Janaína H.eng2019-08-23T00:00:00Zoai:scielo:S0100-40422019004700729Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2019-08-23T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS |
title |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS |
spellingShingle |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS Giertyas,Cristian J. High-performance Liquid Chromatography ion exchange column glycerol oxidation analytical methodologies identification and quantification |
title_short |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS |
title_full |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS |
title_fullStr |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS |
title_full_unstemmed |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS |
title_sort |
IMPROVEMENT OF AN ANALYTICAL METHOD BASED ON HPLC WITH REFRACTIVE INDEX DETECTION FOR THE ANALYSIS OF GLYCEROL OXIDATION PRODUCTS |
author |
Giertyas,Cristian J. |
author_facet |
Giertyas,Cristian J. Silva,Débora S. da Silva,Camila L. F. da Meneghetti,Mario R. Meneghetti,Simoni M. Plentz Almeida,Rusiene M. de Bortoluzzi,Janaína H. |
author_role |
author |
author2 |
Silva,Débora S. da Silva,Camila L. F. da Meneghetti,Mario R. Meneghetti,Simoni M. Plentz Almeida,Rusiene M. de Bortoluzzi,Janaína H. |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Giertyas,Cristian J. Silva,Débora S. da Silva,Camila L. F. da Meneghetti,Mario R. Meneghetti,Simoni M. Plentz Almeida,Rusiene M. de Bortoluzzi,Janaína H. |
dc.subject.por.fl_str_mv |
High-performance Liquid Chromatography ion exchange column glycerol oxidation analytical methodologies identification and quantification |
topic |
High-performance Liquid Chromatography ion exchange column glycerol oxidation analytical methodologies identification and quantification |
description |
The optimized analytical methodology described herein is based on an ion exchange column and an H3PO4 solution (pH 2.24) as the mobile phase, with a flow rate of 0.4 mL min-1 and refractive index detection (RID). On applying the methodology, it was possible to identify 7 products obtained from the oxidation of glycerol with an analysis time of 27 min. The developed method was validated through the evaluation of a series of analytical parameters. The results obtained were evaluated considering the peak area and peak height. The analytical curves showed a correlation coefficient of ≥ 0.986. The coefficient of variation values obtained were ≤ 3.60% for instrumental precision, ≤ 19.36% for intermediate precision in LOQ (1.25 µg mL-1) and ≤ 17.93% for repeatability in LOQ (1.25 µg mL-1) and different days. The limit of quantification established for all compounds was 1.25 µg mL-1 obtained through the parameters of the analytical curve. The accuracy of the method showed recovery values of 85.6 to 112.3% for real fortified sample at 3 concentration levels. Two different samples of glycerol oxidation products were applied to the validated methodology; one obtained from AuNP/SiO2 as catalyst (conversion of 62.42%), and other using AuNP/MWCNT (conversion of 89.5%). |
publishDate |
2019 |
dc.date.none.fl_str_mv |
2019-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019004700729 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422019004700729 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.21577/0100-4042.20170391 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.42 n.7 2019 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318119703805952 |