Resumo: | Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). Material and methods: A test–retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV) = 54.68%; intraclass correlation coefficient (ICC) (95%CI) = 0.59 (0.34–0.77)]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI) = 0.74 (0.55–0.85)–0.94 (0.87–0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. |
id |
SBR-1_f0133c7c9bfa1faf2a2cacd133df7c3d |
---|---|
oai_identifier_str |
oai:scielo:S0482-50042017000200154 |
network_acronym_str |
SBR-1 |
network_name_str |
Revista Brasileira de Reumatologia (Online) |
repository_id_str |
|
spelling |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK)Fixed-flexion radiographyJoint space widthRepeatabilityKneeOsteoarthritisAbstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). Material and methods: A test–retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV) = 54.68%; intraclass correlation coefficient (ICC) (95%CI) = 0.59 (0.34–0.77)]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI) = 0.74 (0.55–0.85)–0.94 (0.87–0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK.Sociedade Brasileira de Reumatologia2017-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042017000200154Revista Brasileira de Reumatologia v.57 n.2 2017reponame:Revista Brasileira de Reumatologia (Online)instname:Sociedade Brasileira de Reumatologia (SBR)instacron:SBR10.1016/j.rbre.2016.11.010info:eu-repo/semantics/openAccessTelles,Rosa WeissCosta-Silva,LucianaMachado,Luciana A.C.Reis,Rodrigo Citton Padilha dosBarreto,Sandhi Mariaeng2017-11-21T00:00:00Zoai:scielo:S0482-50042017000200154Revistahttp://www.scielo.br/scielo.php?script=sci_serial&pid=0482-5004&lng=pt&nrm=isoONGhttps://old.scielo.br/oai/scielo-oai.php||sbre@terra.com.br1809-45700482-5004opendoar:2017-11-21T00:00Revista Brasileira de Reumatologia (Online) - Sociedade Brasileira de Reumatologia (SBR)false |
dc.title.none.fl_str_mv |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) |
title |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) |
spellingShingle |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) Telles,Rosa Weiss Fixed-flexion radiography Joint space width Repeatability Knee Osteoarthritis |
title_short |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) |
title_full |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) |
title_fullStr |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) |
title_full_unstemmed |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) |
title_sort |
Fixed-flexion knee radiography using a new positioning device produced highly repeatable measurements of joint space width: ELSA-Brasil Musculoskeletal Study (ELSA-Brasil MSK) |
author |
Telles,Rosa Weiss |
author_facet |
Telles,Rosa Weiss Costa-Silva,Luciana Machado,Luciana A.C. Reis,Rodrigo Citton Padilha dos Barreto,Sandhi Maria |
author_role |
author |
author2 |
Costa-Silva,Luciana Machado,Luciana A.C. Reis,Rodrigo Citton Padilha dos Barreto,Sandhi Maria |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Telles,Rosa Weiss Costa-Silva,Luciana Machado,Luciana A.C. Reis,Rodrigo Citton Padilha dos Barreto,Sandhi Maria |
dc.subject.por.fl_str_mv |
Fixed-flexion radiography Joint space width Repeatability Knee Osteoarthritis |
topic |
Fixed-flexion radiography Joint space width Repeatability Knee Osteoarthritis |
description |
Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). Material and methods: A test–retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV) = 54.68%; intraclass correlation coefficient (ICC) (95%CI) = 0.59 (0.34–0.77)]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI) = 0.74 (0.55–0.85)–0.94 (0.87–0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042017000200154 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0482-50042017000200154 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.rbre.2016.11.010 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Reumatologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Reumatologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Reumatologia v.57 n.2 2017 reponame:Revista Brasileira de Reumatologia (Online) instname:Sociedade Brasileira de Reumatologia (SBR) instacron:SBR |
instname_str |
Sociedade Brasileira de Reumatologia (SBR) |
instacron_str |
SBR |
institution |
SBR |
reponame_str |
Revista Brasileira de Reumatologia (Online) |
collection |
Revista Brasileira de Reumatologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Reumatologia (Online) - Sociedade Brasileira de Reumatologia (SBR) |
repository.mail.fl_str_mv |
||sbre@terra.com.br |
_version_ |
1750318051528540160 |