Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence

Detalhes bibliográficos
Autor(a) principal: Malik,Rena D.
Data de Publicação: 2016
Outros Autores: Cohn,Joshua A., Fedunok,Pauline A., Chung,Doreen E., Bales,Gregory T.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Braz J Urol (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382016000200327
Resumo: ABSTRACT Purpose: Decision-making regarding surgery for post-prostatectomy incontinence (PPI) is challenging. The 24-hour pad weight test is commonly used to objectively quantify PPI. However, pad weight may vary based upon activity level. We aimed to quantify variability in pad weights based upon patient-reported activity. Materials and Methods: 25 patients who underwent radical prostatectomy were prospectively enrolled. All patients demonstrated clinical stress urinary incontinence without clinical urgency urinary incontinence. On three consecutive alternating days, patients submitted 24-hour pad weights along with a short survey documenting activity level and number of pads used. Results: Pad weights collected across the three days were well correlated to the individual (ICC 0.85 (95% CI 0.74–0.93), p<0.001). The mean difference between the minimum pad weight leakage and maximum leakage per patient was 133.4g (95% CI 80.4–186.5). The mean increase in 24-hour leakage for a one-point increase in self-reported activity level was 118.0g (95% CI 74.3–161.7, p<0.001). Pad weights also varied significantly when self-reported activity levels did not differ (mean difference 51.2g (95% CI 30.3–72.1), p<0.001). Conclusions: 24-hour pad weight leakage may vary significantly on different days of collection. This variation is more pronounced with changes in activity level. Taking into account patient activity level may enhance the predictive value of pad weight testing.
id SBU-1_49932de82db17d203a162abe72d79632
oai_identifier_str oai:scielo:S1677-55382016000200327
network_acronym_str SBU-1
network_name_str International Braz J Urol (Online)
repository_id_str
spelling Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinenceUrinary IncontinenceSuburethral SlingsUrinary SphincterArtificialStressABSTRACT Purpose: Decision-making regarding surgery for post-prostatectomy incontinence (PPI) is challenging. The 24-hour pad weight test is commonly used to objectively quantify PPI. However, pad weight may vary based upon activity level. We aimed to quantify variability in pad weights based upon patient-reported activity. Materials and Methods: 25 patients who underwent radical prostatectomy were prospectively enrolled. All patients demonstrated clinical stress urinary incontinence without clinical urgency urinary incontinence. On three consecutive alternating days, patients submitted 24-hour pad weights along with a short survey documenting activity level and number of pads used. Results: Pad weights collected across the three days were well correlated to the individual (ICC 0.85 (95% CI 0.74–0.93), p<0.001). The mean difference between the minimum pad weight leakage and maximum leakage per patient was 133.4g (95% CI 80.4–186.5). The mean increase in 24-hour leakage for a one-point increase in self-reported activity level was 118.0g (95% CI 74.3–161.7, p<0.001). Pad weights also varied significantly when self-reported activity levels did not differ (mean difference 51.2g (95% CI 30.3–72.1), p<0.001). Conclusions: 24-hour pad weight leakage may vary significantly on different days of collection. This variation is more pronounced with changes in activity level. Taking into account patient activity level may enhance the predictive value of pad weight testing.Sociedade Brasileira de Urologia2016-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382016000200327International braz j urol v.42 n.2 2016reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/S1677-5538.IBJU.2014.0506info:eu-repo/semantics/openAccessMalik,Rena D.Cohn,Joshua A.Fedunok,Pauline A.Chung,Doreen E.Bales,Gregory T.eng2016-05-19T00:00:00Zoai:scielo:S1677-55382016000200327Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2016-05-19T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false
dc.title.none.fl_str_mv Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
title Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
spellingShingle Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
Malik,Rena D.
Urinary Incontinence
Suburethral Slings
Urinary Sphincter
Artificial
Stress
title_short Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
title_full Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
title_fullStr Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
title_full_unstemmed Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
title_sort Assessing variability of the 24-hour pad weight test in men with post-prostatectomy incontinence
author Malik,Rena D.
author_facet Malik,Rena D.
Cohn,Joshua A.
Fedunok,Pauline A.
Chung,Doreen E.
Bales,Gregory T.
author_role author
author2 Cohn,Joshua A.
Fedunok,Pauline A.
Chung,Doreen E.
Bales,Gregory T.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Malik,Rena D.
Cohn,Joshua A.
Fedunok,Pauline A.
Chung,Doreen E.
Bales,Gregory T.
dc.subject.por.fl_str_mv Urinary Incontinence
Suburethral Slings
Urinary Sphincter
Artificial
Stress
topic Urinary Incontinence
Suburethral Slings
Urinary Sphincter
Artificial
Stress
description ABSTRACT Purpose: Decision-making regarding surgery for post-prostatectomy incontinence (PPI) is challenging. The 24-hour pad weight test is commonly used to objectively quantify PPI. However, pad weight may vary based upon activity level. We aimed to quantify variability in pad weights based upon patient-reported activity. Materials and Methods: 25 patients who underwent radical prostatectomy were prospectively enrolled. All patients demonstrated clinical stress urinary incontinence without clinical urgency urinary incontinence. On three consecutive alternating days, patients submitted 24-hour pad weights along with a short survey documenting activity level and number of pads used. Results: Pad weights collected across the three days were well correlated to the individual (ICC 0.85 (95% CI 0.74–0.93), p<0.001). The mean difference between the minimum pad weight leakage and maximum leakage per patient was 133.4g (95% CI 80.4–186.5). The mean increase in 24-hour leakage for a one-point increase in self-reported activity level was 118.0g (95% CI 74.3–161.7, p<0.001). Pad weights also varied significantly when self-reported activity levels did not differ (mean difference 51.2g (95% CI 30.3–72.1), p<0.001). Conclusions: 24-hour pad weight leakage may vary significantly on different days of collection. This variation is more pronounced with changes in activity level. Taking into account patient activity level may enhance the predictive value of pad weight testing.
publishDate 2016
dc.date.none.fl_str_mv 2016-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382016000200327
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382016000200327
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1677-5538.IBJU.2014.0506
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Urologia
publisher.none.fl_str_mv Sociedade Brasileira de Urologia
dc.source.none.fl_str_mv International braz j urol v.42 n.2 2016
reponame:International Braz J Urol (Online)
instname:Sociedade Brasileira de Urologia (SBU)
instacron:SBU
instname_str Sociedade Brasileira de Urologia (SBU)
instacron_str SBU
institution SBU
reponame_str International Braz J Urol (Online)
collection International Braz J Urol (Online)
repository.name.fl_str_mv International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)
repository.mail.fl_str_mv ||brazjurol@brazjurol.com.br
_version_ 1750318074892910592