Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques

Detalhes bibliográficos
Autor(a) principal: Rao,Sandhya R.
Data de Publicação: 2014
Outros Autores: Moussly,Sammy, Pacheco,Michelle, Spiess,Philippe E., Sexton,Wade J.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: International Braz J Urol (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382014000500637
Resumo: Purpose To compare retrograde dye injection through an externalized ureteral catheter with direct needle injection of dye into proximal ureter for identification of unrecognized collecting system disruption and integrity of subsequent repair during open partial nephrectomy. Materials and Methods We retrospectively reviewed the records of 259 consecutive patients who underwent open partial nephrectomy. Externalized ureteral catheters were placed preoperatively in 110 patients (Group 1); needle injection of methylene blue directly into proximal ureter was used in 120 patients (Group 2). No assessment of the collecting system was performed in 29 patients (Group 3). We compared intraoperative parameters, tumor characteristics, collecting system entry and incidence of urine leaks among the three groups. Results The mean tumor diameter was 3.1cm in Group 1, 3.6cm in Group 2, and 3.8 cm in Group 3 (p = 0.04); mean EBL 320cc, 351 cc and 376cc (p = 0.5); mean operative time 193.5 minutes, 221 minutes and 290 minutes (p < 0.001). Collecting system entry was recognized in 63%, 76% and 38% of cases in Groups 1, 2 and 3 respectively. (p = 0.07). Postoperative urine leaks requiring some form of management occurred in 11 patients from group 1 and 6 from group 2. (p = 0.2). No patient in Group 3 developed a urinary leak. Conclusions Identification of unrecognized collecting system disruption as well as postoperative urine leak rate in patients undergoing partial nephrectomy were not influenced by the intraoperative technique of identifying unrecognized collecting system entry. Postoperative urine leaks are uncommon despite recognized collecting system disruption in the majority of patients.
id SBU-1_8cb30817967e76d83ed65de9260982d2
oai_identifier_str oai:scielo:S1677-55382014000500637
network_acronym_str SBU-1
network_name_str International Braz J Urol (Online)
repository_id_str
spelling Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniquesUrinary fistulapartial nephrectomycomplicationsstentmethylene blue Purpose To compare retrograde dye injection through an externalized ureteral catheter with direct needle injection of dye into proximal ureter for identification of unrecognized collecting system disruption and integrity of subsequent repair during open partial nephrectomy. Materials and Methods We retrospectively reviewed the records of 259 consecutive patients who underwent open partial nephrectomy. Externalized ureteral catheters were placed preoperatively in 110 patients (Group 1); needle injection of methylene blue directly into proximal ureter was used in 120 patients (Group 2). No assessment of the collecting system was performed in 29 patients (Group 3). We compared intraoperative parameters, tumor characteristics, collecting system entry and incidence of urine leaks among the three groups. Results The mean tumor diameter was 3.1cm in Group 1, 3.6cm in Group 2, and 3.8 cm in Group 3 (p = 0.04); mean EBL 320cc, 351 cc and 376cc (p = 0.5); mean operative time 193.5 minutes, 221 minutes and 290 minutes (p < 0.001). Collecting system entry was recognized in 63%, 76% and 38% of cases in Groups 1, 2 and 3 respectively. (p = 0.07). Postoperative urine leaks requiring some form of management occurred in 11 patients from group 1 and 6 from group 2. (p = 0.2). No patient in Group 3 developed a urinary leak. Conclusions Identification of unrecognized collecting system disruption as well as postoperative urine leak rate in patients undergoing partial nephrectomy were not influenced by the intraoperative technique of identifying unrecognized collecting system entry. Postoperative urine leaks are uncommon despite recognized collecting system disruption in the majority of patients. Sociedade Brasileira de Urologia2014-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382014000500637International braz j urol v.40 n.5 2014reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/S1677-5538.IBJU.2014.05.08info:eu-repo/semantics/openAccessRao,Sandhya R.Moussly,SammyPacheco,MichelleSpiess,Philippe E.Sexton,Wade J.eng2014-12-11T00:00:00Zoai:scielo:S1677-55382014000500637Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2014-12-11T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false
dc.title.none.fl_str_mv Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
title Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
spellingShingle Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
Rao,Sandhya R.
Urinary fistula
partial nephrectomy
complications
stent
methylene blue
title_short Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
title_full Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
title_fullStr Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
title_full_unstemmed Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
title_sort Identifying unrecognized collecting system entry and the integrity of repair during open partial nephrectomy: comparison of two techniques
author Rao,Sandhya R.
author_facet Rao,Sandhya R.
Moussly,Sammy
Pacheco,Michelle
Spiess,Philippe E.
Sexton,Wade J.
author_role author
author2 Moussly,Sammy
Pacheco,Michelle
Spiess,Philippe E.
Sexton,Wade J.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Rao,Sandhya R.
Moussly,Sammy
Pacheco,Michelle
Spiess,Philippe E.
Sexton,Wade J.
dc.subject.por.fl_str_mv Urinary fistula
partial nephrectomy
complications
stent
methylene blue
topic Urinary fistula
partial nephrectomy
complications
stent
methylene blue
description Purpose To compare retrograde dye injection through an externalized ureteral catheter with direct needle injection of dye into proximal ureter for identification of unrecognized collecting system disruption and integrity of subsequent repair during open partial nephrectomy. Materials and Methods We retrospectively reviewed the records of 259 consecutive patients who underwent open partial nephrectomy. Externalized ureteral catheters were placed preoperatively in 110 patients (Group 1); needle injection of methylene blue directly into proximal ureter was used in 120 patients (Group 2). No assessment of the collecting system was performed in 29 patients (Group 3). We compared intraoperative parameters, tumor characteristics, collecting system entry and incidence of urine leaks among the three groups. Results The mean tumor diameter was 3.1cm in Group 1, 3.6cm in Group 2, and 3.8 cm in Group 3 (p = 0.04); mean EBL 320cc, 351 cc and 376cc (p = 0.5); mean operative time 193.5 minutes, 221 minutes and 290 minutes (p < 0.001). Collecting system entry was recognized in 63%, 76% and 38% of cases in Groups 1, 2 and 3 respectively. (p = 0.07). Postoperative urine leaks requiring some form of management occurred in 11 patients from group 1 and 6 from group 2. (p = 0.2). No patient in Group 3 developed a urinary leak. Conclusions Identification of unrecognized collecting system disruption as well as postoperative urine leak rate in patients undergoing partial nephrectomy were not influenced by the intraoperative technique of identifying unrecognized collecting system entry. Postoperative urine leaks are uncommon despite recognized collecting system disruption in the majority of patients.
publishDate 2014
dc.date.none.fl_str_mv 2014-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382014000500637
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382014000500637
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1677-5538.IBJU.2014.05.08
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Urologia
publisher.none.fl_str_mv Sociedade Brasileira de Urologia
dc.source.none.fl_str_mv International braz j urol v.40 n.5 2014
reponame:International Braz J Urol (Online)
instname:Sociedade Brasileira de Urologia (SBU)
instacron:SBU
instname_str Sociedade Brasileira de Urologia (SBU)
instacron_str SBU
institution SBU
reponame_str International Braz J Urol (Online)
collection International Braz J Urol (Online)
repository.name.fl_str_mv International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)
repository.mail.fl_str_mv ||brazjurol@brazjurol.com.br
_version_ 1750318073728991232