Resumo: | ABSTRACT Purpose: To evaluate the efficiency of a novel device coupled with ultrassound for renal percutaneous puncture. Materials and Methods: After establishing hydronephrosis, ten pigs had three calyxes of each kidney punctured by the same urology resident, with and without the new device ("Punctiometer"). Time for procedure completion, number of attempts to reach the calyx, puncture precision and puncture complications were recorded in both groups and compared. Results: Puncture success on the first attempt was achieved in 25 punctures (83%) with the Punctiometer and in 13 punctures (43%) without the Punctiometer (p=0.011). The mean time required to perform three punctures in each kidney was 14.5 minutes with the Punctiometer and 22.4 minutes without the Punctiometer (p=0.025). The only complications noted were renal hematomas. In the Punctiometer group, all kidneys had small hematomas. In the no Punctiometer group 80% had small hematomas, 10% had a medium hematoma and 10% had a big hematoma. There was no difference in complications between both groups. Conclusions: The Punctiometer is an effective device to increase the likelihood of an accurate renal calyx puncture during PCNL, with a shorter time required to perform the procedure. |
id |
SBU-1_9418b455f41c51c7f638e0ccb7f275f9 |
---|---|
oai_identifier_str |
oai:scielo:S1677-55382015000500953 |
network_acronym_str |
SBU-1 |
network_name_str |
International Braz J Urol (Online) |
repository_id_str |
|
spelling |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasoundPunctiometerpercutaneous accesskidney punctionnephrolitotripsyultrassoundABSTRACT Purpose: To evaluate the efficiency of a novel device coupled with ultrassound for renal percutaneous puncture. Materials and Methods: After establishing hydronephrosis, ten pigs had three calyxes of each kidney punctured by the same urology resident, with and without the new device ("Punctiometer"). Time for procedure completion, number of attempts to reach the calyx, puncture precision and puncture complications were recorded in both groups and compared. Results: Puncture success on the first attempt was achieved in 25 punctures (83%) with the Punctiometer and in 13 punctures (43%) without the Punctiometer (p=0.011). The mean time required to perform three punctures in each kidney was 14.5 minutes with the Punctiometer and 22.4 minutes without the Punctiometer (p=0.025). The only complications noted were renal hematomas. In the Punctiometer group, all kidneys had small hematomas. In the no Punctiometer group 80% had small hematomas, 10% had a medium hematoma and 10% had a big hematoma. There was no difference in complications between both groups. Conclusions: The Punctiometer is an effective device to increase the likelihood of an accurate renal calyx puncture during PCNL, with a shorter time required to perform the procedure.Sociedade Brasileira de Urologia2015-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382015000500953International braz j urol v.41 n.5 2015reponame:International Braz J Urol (Online)instname:Sociedade Brasileira de Urologia (SBU)instacron:SBU10.1590/S1677-5538.IBJU.2014.0586info:eu-repo/semantics/openAccessChan,Chen JenSrougi,VictorTanno,Fabio YoshiakiJordão,Ricardo DuarteSrougi,Migueleng2015-11-27T00:00:00Zoai:scielo:S1677-55382015000500953Revistahttp://www.brazjurol.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||brazjurol@brazjurol.com.br1677-61191677-5538opendoar:2015-11-27T00:00International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU)false |
dc.title.none.fl_str_mv |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound |
title |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound |
spellingShingle |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound Chan,Chen Jen Punctiometer percutaneous access kidney punction nephrolitotripsy ultrassound |
title_short |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound |
title_full |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound |
title_fullStr |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound |
title_full_unstemmed |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound |
title_sort |
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound |
author |
Chan,Chen Jen |
author_facet |
Chan,Chen Jen Srougi,Victor Tanno,Fabio Yoshiaki Jordão,Ricardo Duarte Srougi,Miguel |
author_role |
author |
author2 |
Srougi,Victor Tanno,Fabio Yoshiaki Jordão,Ricardo Duarte Srougi,Miguel |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Chan,Chen Jen Srougi,Victor Tanno,Fabio Yoshiaki Jordão,Ricardo Duarte Srougi,Miguel |
dc.subject.por.fl_str_mv |
Punctiometer percutaneous access kidney punction nephrolitotripsy ultrassound |
topic |
Punctiometer percutaneous access kidney punction nephrolitotripsy ultrassound |
description |
ABSTRACT Purpose: To evaluate the efficiency of a novel device coupled with ultrassound for renal percutaneous puncture. Materials and Methods: After establishing hydronephrosis, ten pigs had three calyxes of each kidney punctured by the same urology resident, with and without the new device ("Punctiometer"). Time for procedure completion, number of attempts to reach the calyx, puncture precision and puncture complications were recorded in both groups and compared. Results: Puncture success on the first attempt was achieved in 25 punctures (83%) with the Punctiometer and in 13 punctures (43%) without the Punctiometer (p=0.011). The mean time required to perform three punctures in each kidney was 14.5 minutes with the Punctiometer and 22.4 minutes without the Punctiometer (p=0.025). The only complications noted were renal hematomas. In the Punctiometer group, all kidneys had small hematomas. In the no Punctiometer group 80% had small hematomas, 10% had a medium hematoma and 10% had a big hematoma. There was no difference in complications between both groups. Conclusions: The Punctiometer is an effective device to increase the likelihood of an accurate renal calyx puncture during PCNL, with a shorter time required to perform the procedure. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382015000500953 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382015000500953 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1677-5538.IBJU.2014.0586 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Urologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Urologia |
dc.source.none.fl_str_mv |
International braz j urol v.41 n.5 2015 reponame:International Braz J Urol (Online) instname:Sociedade Brasileira de Urologia (SBU) instacron:SBU |
instname_str |
Sociedade Brasileira de Urologia (SBU) |
instacron_str |
SBU |
institution |
SBU |
reponame_str |
International Braz J Urol (Online) |
collection |
International Braz J Urol (Online) |
repository.name.fl_str_mv |
International Braz J Urol (Online) - Sociedade Brasileira de Urologia (SBU) |
repository.mail.fl_str_mv |
||brazjurol@brazjurol.com.br |
_version_ |
1750318074489208832 |